Dacor Discovery MOH230 Installation Instructions Manual Download Page 8

6

“C”

9 5/8” (244mm) 

Recommended 

(May be altered) 

1 ¾“ (45mm)

Clear to Top 

of Drawer for 

Heat Exhaust

“B” 

“A” 

4“ Typical Toe Kick (Shown) 

Recommended 

Electrical  

Location 

3/4” (19mm) 

Support Platform 

1“ (25mm) 

Clear to Top  

of Drawer for  

Heat Exhaust 

“C”

“A” 

“B” 

31 1/4” (794mm) 

Recommended 

(May be Altered) 

1 ¾“ (45mm) Min.

Clear to Top of

Door for Heat

Exhaust

4“ Typical Toe Kick (Shown) 

Recommended 

Electrical  

Location 

Alternate 

Electrical  

Location 

3/4” (19mm) 

Support Platform 

1“ (25mm) Min.

Clear to Top of

Door for Heat

Exhaust

Planning the Installation

Model 

Number

A

B

C

D

EO127

27 7/16”

(697mm)

25 1/2”

(648mm)

27”

(686mm)

56 1/2” 

(1435mm)

PO127

MOV127

MOH127

EO130

28 1/2”

(724mm)

30”

(762mm)

62 1/2” 

(1588mm)

PO130

MOV130

MOV130

EO227

50 9/16” 

(1284mm)

25 1/2”

(648mm)

27”

(686mm)

NA

PO227

MOV227

MOH227

EO230

28 1/2”

(724mm)

30”

(762mm)

PO230

MOV230

MOH230

Single Wall 

Oven Cutout

Double Wall 

Oven Cutout

Selecting the Location

Carefully check the location where the oven is to be 

• 

installed. The oven should be placed for convenient 
access, but away from drafts that may be caused 
by doors, windows, and heating, ventilation and air 
conditioning outlets. 

Make certain that electrical power can be provided 

• 

in the selected location. Be certain that proper 
clearance is provided for the oven door when it is in 
the open position.

Cabinet Cut-Out

Plan the installation so that all minimum clearances 

• 

are met or exceeded. Cutout dimensions shown 
provide minimum clearances, unless otherwise 
noted. 

The specified minimum cabinet depth and width 

• 

must be provided. The cabinet depth and width 
must completely enclose the recessed portion of 
the oven.

Cabinet cutout dimensions must be used as indi-

• 

cated.

Summary of Contents for Discovery MOH230

Page 1: ...Installation Instructions Discovery Wall Oven For use with models EO MO and PO Part No 65433 Rev F Preliminary For Review Only No Scheduled Release Date...

Page 2: ...All specifications are subject to change without notice Dacor assumes no liability for changes to specifications 2007 Dacor all rights reserved...

Page 3: ...s completely and care fully before you begin the installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the...

Page 4: ...nless specifically instructed to do so in this manual warning General Safety Precautions To reduce the risk of fire electric shock serious injury or death when using your appliance follow basic safety...

Page 5: ...with installation con tact your Dacor dealer or the Dacor Customer Service Team When you call have the model and serial num ber of the appliance ready The model and serial num ber are printed on the a...

Page 6: ...28 3 8 721mm PO130 MOV130 MOV130 EO227 27 686mm 51 3 32 1298mm 49 1 2 1257mm 25 3 8 644mm PO227 MOV227 MOH227 EO230 30 762mm 28 3 8 721mm PO230 MOV230 MOH230 Handle Dimensions All Models Side View Doo...

Page 7: ...duct Specifications Single Wall Oven Dimension Double Wall Oven Dimension R N P Q M 1 1 16 27mm 66 1676mm Flexible Conduit K L 1 1 4 32mm S M L 1 1 4 32mm P N 1 1 16 27mm R 66 1676mm Flexible Conduit...

Page 8: ...686mm NA PO227 MOV227 MOH227 EO230 28 1 2 724mm 30 762mm PO230 MOV230 MOH230 Single Wall Oven Cutout Double Wall Oven Cutout Selecting the Location Carefully check the location where the oven is to be...

Page 9: ...of Door for Heat Exhaust 31 1 4 794mm Recommended May be Altered 4 Typical Toe Kick Shown 3 4 19mm Support Platform 3 4 19mm Support Platform 4 102mm Min Between Cutout Recommended Electrical Location...

Page 10: ...he oven to malfunction See below Provide a platform within the cabinet to support the oven A properly supported piece of 3 4 19mm thick plywood is recommended All contact surfaces between the applianc...

Page 11: ...p plied to the appliance from a dedicated grounded single phase circuit that is protected by a properly sized circuit breaker or time delay fuse If a time delay fuse is utilized fuse both sides of the...

Page 12: ...oduct specifications do not proceed with the installation Call a licensed electrician to install the required wiring To prevent an electric shock or fire hazard turn off power to the circuit at the ci...

Page 13: ...ding screw The grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials Any insulating materials must be jumped with a minimum 4 AWG...

Page 14: ...pper door is removed Remove the oven door s Due to the weight of this appliance remove the door s to reduce the lifting load Removing the door s will also pro vide a place to grip the oven when liftin...

Page 15: ...abinet Be certain to take all necessary safety precau tions Resting the oven on the cabinet support platform slide 3 the oven into the recessed area until the rear edge of the oven trim post is flush...

Page 16: ...he use and 5 care manual NOTES If the oven does not operate properly follow these troubleshooting steps Verify that power is supplied to the oven Check for proper electrical connection Repeat the abov...

Page 17: ...10 Oven is level See page 13 Oven is secured into cabinet with included screws See page 13 Exhaust deflector has been installed See page 14 Oven door s have been properly re installed See page 14 Pla...

Page 18: ...16 Notes...

Page 19: ......

Page 20: ...Dacor 1440 Bridge Gate Drive Diamond Bar CA 91765 Tel 800 793 0093 FAX 626 403 3130 www Dacor com...

Reviews: