All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
EG366, EG486
Discovery
™
36” and 48” Wide
Slide-in Gas Cooktops
Document # PG04-001
Revised 09/27/12 Page 1/4
A
ELECtrIC CIrCUIt rEqUIrEmENtS
Circuit Required
Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire)
0.25 Amp @ 120 Vac, 60 Hz
GAS SUPPLy PrESSUrE rEqUIrEmENtS*
Gas Type
Manifold Pressure
Minimum Gas Supply
Pressure
Natural Gas
5” Water Column
6” Water Column
Propane (LP)
10” Water Column
11” Water Column
* Maximum gas supply pressure for all models is 1/2 psi
IMPORTANT:
Installation of a non-combustible material* (up to the hood) or
a backsplash is always recommended, and mandatory if the distance to the
back wall from the cooktop is less than 2 1/2” (Figure 2). When installing a
backguard, use only Dacor model numbers AEB3609, AEB3612 (EG366),
AEB4809 or AEB4812 (EG486).
CAbINEt/CoUNtErtoP SIDE VIEW WIthoUt bACkGUArD
CAbINEt/CoUNtErtoP SIDE VIEW WIth bACkGUArD
ProDUCt DImENSIoNS - SIDE VIEW
ProDUCt DImENSIoNS - ISo VIEW
A - Width
EG366
35 7/8” (91.1 cm)
EG486
47 7/8” (121.6 cm)
Product tolerances: ±1/16” (±1.6 mm) unless otherwise noted
WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
4” (10.2 cm)
5/8”
(1.6 cm)
7 3/4”
(19.7 cm)
Trim:
7/16”
(1.1 cm)
thick
26” (66.0 cm)
1 1/2” (3.8 cm) cooking surface
height (grate level) above
countertop
3/4” gas inlet, connects to regulator from
bottom or rear of unit, end is recessed
2” (5.1 cm) from chassis bottom
27” (68.6 cm)
28” (71.1 cm)
Power cord
32” long
Combustible
rear wall
Backguard mandatory if
gap from back of cooktop
to combustible wall is less
than 2 1/2”
Combustible
rear wall
2 1/2” (6.4 cm) min. to
combustible rear wall