Replacing the Gas Cylinder

 DANGER

IMPORTANT:

 Use only the argon gas cylinder type 

specified in this manual with this appliance. Use of any 

other type gas or cylinder may result in explosion, fire 

and personal injury.

 WARNING

To avoid personal injury, use only the included gas 

pressure regulator or a Dacor specified replacement.

Replace the gas cylinder when any of the red lights 

come on solid or when a message appears on the 

screen telling you to replace it.
1.  Open the door on the front of the unit. Then 

swing the spout cover to the up position. 

2.  Slide the power switch, located on the left side 

of the bottle bay, all the way down to the OFF 

position.

Care and Cleaning

Spout cover 

release lever 

(on bottom of 

spout cover)

ON

OFF

3.  Grasp the regulator assembly with one hand and 

turn the used gas cylinder counter-clockwise 

until is comes loose.

4.  Remove the plastic cap from the top of the new 

gas cylinder.

5.  Insert the top of the new gas cylinder into the 

bottom of the gas regulator assembly and turn 

clockwise until snug. Do not over-tighten.

6.  Slide the power switch all the way up to the ON 

position. The system will run through a series of 

self-tests, which could take up to approximately 

5 minutes. Once this process is completed, the 

blue lights below the LCD screens will be illumi-

nated, indicating that the unit is ready for use.

7.  push firmly up on the lever on the bottom of 

the spout cover and hold it up as you lower the  

cover into place. CAUTION: Do not push down 

on the spout cover without pushing up on the 

lever. Damage to the lever will result.

8.  Close the door.

Gas Cylinder Removal

Regulator 

assembly

Argon 

gas  

cylinder

Summary of Contents for Discovery DYWS4

Page 1: ...chnology Model DYWS4 Ta b l e o f C o n t e n t s Important Safety Instructions 1 Getting to Know Your Wine Dispensing System 3 Setting Up Your Wine Dispensing System 7 Operating Your Wine Dispensing System 8 Parts and Accessories 22 Before You Call for Service 22 Warranty and Service 24 Warranty Card Back Cover ...

Page 2: ... 2013 Dacor all rights reserved ...

Page 3: ...ULD result in minor personal injury or property damage DANGER IMPORTANT Do not store or use combustible flammable or explosive vapors and liquids such as gasoline inside or in the vicinity of this or any other appliance Use only the argon gas cylinder type specified in this manual with this appliance Use of any other type of gas or cylinder may result in explosion fire and personal injury WARNING ...

Page 4: ...ouch other parts of the appliance Keep the argon gas cylinders out of reach of children Do not tamper with the controls Only allow individuals to use the wine dispensing system who are able to operate it properly To avoid an electric shock hazard or other personal injury do not put body parts or any other objects into any opening air vent the base grille or the bottom of the appliance Keep all cle...

Page 5: ... personal wine collec tion without having to throw away left over wine at the end of the evening With the purchase of additional dispensing heads you can remove bottles of wine with the dispensing head still attached that you are not currently using and store them for later use in the refrigerator The wine will continue to be preserved for up to two weeks because the argon gas stays in the bottle ...

Page 6: ...e through to allow you to read the bottle labels with the door closed When the key is removed the lock on the door prevents access to the wine bottles in two ways First it prevents direct access to the wine bottles by keeping the door from opening Second when the control panel is locked see page 15 the lock on the door prevents access to the main power switch which is required to unlock the contro...

Page 7: ... installed below the particular display It can be programed with specific informa tion about each type of wine being served see page 12 The display is also used for programming the various system functions J Status lights red These lights come on to help inform you of the status of your wine dispensing system See the table below K Purge P button Use this button to purge air from the bottle when a ...

Page 8: ...is in use D Main body The main body is cleanable to help assure that everything that touches the wine is sanitary E Collar Expands the gasket underneath it Turn it to secure the head on top of the bottle F Gasket The gasket is located under the collar When it is expanded it seals air out and keeps the argon gas in in addition to holding the head in place on top of the bottle The gaskets are interc...

Page 9: ...y lift the unit up and into the final location Exercise care to make sure that the wiring and tubing lines do not become dam aged Make sure the required 1 2 5 cm space is maintained above and below the unit Setting Up Your Wine Dispensing System Plastic gas tubing Connect power supply output here 120 Vac power cord Connect to 120 Vac 60 Hz electrical outlet These connectors for use by qualified se...

Page 10: ... Push in slightly just above the lock until it snaps shut Regulator adjustment knob Gas supply line from wine dispensing system Regulator assembly Argon gas cylinder Spout cover release lever on bottom of spout cover 9 Find the gas regulator assembly that comes with the unit WARNING To avoid personal injury use only the included gas pressure regulator or a Dacor specified replacement 11 Make sure ...

Page 11: ...spensing Heads Caution To avoid dropping a wine bottle when carrying it around with the dispensing head attached always hold the bottle itself not just the head 1 Open the bottle and place it on a flat dry sur face 2 Insert the head selection tool into the bottleneck to determine the correct color coded gasket size NOTE The red gasket should work with most wines bottled in North America If you nee...

Page 12: ...the head in place with one hand With your other hand fully un tighten the collar until it touches the main body Remove the dispensing head from the bottle and detach it from the pickup tube Check the gasket for damage If needed replace with an undam aged head Check the correct gasket size If needed switch to a wider gasket size Wipe the gasket and inner part of the bottleneck dry and try again Ope...

Page 13: ...ecommends replacing the pickup tube with each bottle change but the pick up tube may be washed out in a mild solution of warm water and dishwashing soap rinsed out and reused 6 Attach the dispensing head to a new bottle of wine according to the instructions starting on page 9 Insert the new wine bottle into the system according to the instructions on the facing page Accessing the Main Service Menu...

Page 14: ... display repeat edly to select 1 Year 10 Year or No Year When the display is set to 10 Year the display jumps 10 years every time the up and down buttons on the right are pushed You must push Select Wine to exit after changing the year NOTE When large year changes need to be made adjust the last digit first then the 10 year increments Push Select Wine Push Red White or Other to select the wine typ...

Page 15: ...he Volume ounces Dispensed and or Display Bottle Description 1 Push Wine Display 2 Push Set VOL 3 Push the button for which you want to adjust the pour volume for example 1oz 4 Push the up and down buttons on the right to select the pour volume then push Exit 5 You may select another button to adjust the volume or push Exit continued Purge Bottle Display Wine Exit Detect Pour Bottle Service Wine S...

Page 16: ... on the control panel is pushed Operating Your Wine Dispensing System Changing Individual Bottle Settings cont Turning Pour Detect On or Off The wine dispensing system can detect if there is a fault in the pouring capabilities of each bottle posi tion 1 Turn Pour Detect on or off from the main ser vice menu see page 11 Push Bottle Ser vice next to display for the bottle bay that needs to have the ...

Page 17: ...Exit 3 Slide the power switch up to the ON position 4 Lower the spout cover and close the front door 5 The entire control panel is now unlocked NOTE There is no unlock button The process of entering the service menu and exiting unlocks the display Setting the System Temperature System Fan and Temperature Scale F C The system has three temperature settings OFF ON and MAX When the the system is set ...

Page 18: ...witch up to the ON position 8 Lower the spout cover and close the front door Diagnostic Screen When calling Dacor with questions about your wine dispensing system the Customer Service represen tative may ask you to access this screen for infor mation To access the diagnostic screen 1 From the main service menu see page 11 push WineStation Service next to any of the displays 1 Push More 2 Push Diag...

Page 19: ...4 until all of the desired let ters numbers have been changed then push Exit Operating Your Wine Dispensing System Exit Our Wine Cellar 6 Slide the power switch up to the ON position The new system name will appear on all four displays 7 Lower the spout cover and close the front door Display Contrast Brightness Settings The contrast and brightness of each LCD screen can be adjusted separately To a...

Page 20: ...wein Muscardin St Laurent Baco Noir Fiano Muscat Terret Blanc Barbaresco Frascati Negrette Terret Gris Bardolino Gamay Neuburger Terret Noir Beaujolais Garganega Niagra Tinta Cao Black Corinth Grappa Picpoul Blanc Tinta Narroca Blush Grenache Blanc Picpoul Tinta Negra Mole Bourboulenc Grenache Gris Piedmont Ugni Blanc Trebbiano Carignan Grignolino Pinot Meunier Vaccarese Camarese Carmenere Gros Ve...

Page 21: ... of each day the wine dis pensing system is used Cleaning the Dispensing Heads Dacor recommends cleaning the heads and pick up tubes with each bottle change To clean the dispens ing head follow these steps 1 Remove the pick up tube and discard or wash it out in a mild solution of warm water and dish washing soap then rinse it out 2 Remove the cap from the head body by turning the cap counterclockw...

Page 22: ...ording to the directions on the package Changing Replacing the Clean Pour Head Gasket The Clean Pour head is designed to provide ease of use and cost effective replacement when damaged To replace the head gasket 1 Locate the threaded nut on the bottom of the head assembly 2 Un thread the gasket nut by turning it in a coun ter clockwise direction If it is difficult to turn you may use needle nose p...

Page 23: ...t cover ON OFF 3 Grasp the regulator assembly with one hand and turn the used gas cylinder counter clockwise until is comes loose 4 Remove the plastic cap from the top of the new gas cylinder 5 Insert the top of the new gas cylinder into the bottom of the gas regulator assembly and turn clockwise until snug Do not over tighten 6 Slide the power switch all the way up to the ON position The system w...

Page 24: ...o access the main service menu 4 Push WineStation Service next to any of the displays 5 Push MORE 6 Push GLT to start the test 7 When the test is complete push EXIT then slide the power switch up to the ON position 8 Push up on the spout cover release lever lower the spout cover and close the front door 9 Reattach the argon gas cylinder to the bottom of the gas regulator assembly turn clockwise un...

Page 25: ...sed Visit www everythingdacor com to order your free argon gas cylinder or to order additional parts and acces sories Before You Call for Service Problem Solution Guide Problem May Be Caused By What to Do Nothing works display is dark Power switch is off Make sure main power switch is in ON position See page 8 for location Slide all the way up System not connected to electri cal power Check to mak...

Page 26: ...p of a pencil Carefully push on the pins They should be springy If they are sticky they may need to be carefully cleaned using a contact cleaner and aerosol spray that can be purchased at most hardware stores Dispensing head is loose Check to make sure head is tight on bottle See page 9 Dispensing head cap is on back wards Check to make sure cap is in the right ori entation See page 19 Multiple re...

Page 27: ... hissing continues remove gas cylinder from regulator and call Dacor for replacement regulator assembly Suspected gas leak Gas cylinder emptying too quickly One or more dispensing head caps loose Check all dispensing heads to ensure that the caps are correctly engaged and secure Leak in gas supply system Run gas leak test see page 11 Call for service if test fails Before You Call for Service Warra...

Page 28: ... you This warranty gives you specific legal rights and you may also have other rights that vary from state to state Warranty and Service Warranty What is Covered CERTIFICATE OF WARRANTIES DACOR WINE DISPENSING SYSTEM WITHIN THE FIFTY STATES OF THE U S A THE DISTRICT OF COLUMBIA AND CANADA FULL ONE YEAR WARRANTY The warranty applies only to the Dacor appliance sold to the first use purchaser starti...

Page 29: ...27 Notes ...

Page 30: ...28 Notes ...

Page 31: ...RRANTY PROCESSING DEPT PO BOX 90070 CITY OF INDUSTRY CA 91715 9907 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS MAIL CITY OF INDUSTRY CA PERMIT NO 1600 POSTAGE WILL BE PAID BY ADDRESSEE ...

Page 32: ...ne G Architect Designer C Appliance Dealer Showroom H Another Dacor Owner D Kitchen Dealer Showroom I Model Home E Home Show J Other 2 Where did you buy your Dacor appliances A Appliance Dealer D Builder B Kitchen Dealer E Other C Builder Supplier 3 For what purpose was the product purchased A Replacement only C New Home B Part of a Remodel D Other 4 What is your household income A Under 75 000 D ...