background image

11

Installation Instructions

Refer to the range rating label (see page II) for power 

requirements.
There are four possible ways to wire the range:
• 

4 wire conduit

• 

3 wire conduit (where local codes permit)

• 

4 wire appliance cord (where local codes permit)

• 

3 wire appliance cord (where local codes permit)

The sections below and on the following pages give directions for 

connecting each type of wiring harness.

 

WARNING

Do not connect the green appliance wire to the neutral (white) 

supply wire unless local building codes permit.

Connecting Conduit to the Range

NOTE:

 For connection of an appliance cord, see page 14.

1.  Remove the range electrical access cover from the back of 

the range.

2.  If using a 4 wire 

connection, loosen the 

grounding screw and 

remove the neutral to 

ground jumper link.

3.  Remove the nut from the 

conduit strain relief (not 

included).

4.  Slide the wires and the 

end of the strain relief into 

the hole on the bottom of 

the range electrical box.

5.  Before connecting the wires, slide the strain relief nut over 

the wires and thread it onto the conduit strain relief inside the 

box. Tighten into place.

6.  Connect the white wire to the neutral terminal in the box.
7.  Connect the black wire to the L1 power supply terminal.
8.  Connect the red wire to the L2 power supply terminal.
9.  If using a 4 wire connection, connect the green wire to the 

grounding screw inside the box.

10.  Replace the range electrical access cover.

Bare wire 

connections

Loop and  

spade terminal 

connections

L1 terminal

L1 terminal

L2 terminal

L2 terminal

Black wire

Red wire

White wire

Green wire

Red wire

White wire

Black wire

Conduit strain 

relief nut

Conduit strain 

relief nut

Neutral terminal

Neutral terminal

Jumper link

Jumper removed

Grounding screw

Connecting 3 Wire Conduit to Range -  

Where Local Code Permits

Connecting 4 Wire Conduit to Range

Wire Connection Detail

Summary of Contents for Discovery DYRP48DSNGH

Page 1: ...s Discovery Range Part No 108106 Rev B THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITIONS OF ANSI Z21 1 UL858 AND UL60730 1 STANDARDS FOR HOUSEHOLD APPLIANCES Models DYRP36DS DYRP36D C S DYRP48DS DYRP48D C S ...

Page 2: ...klist 19 Customer Service Information If you have questions or problems with installation contact your Dacor dealer or the Dacor Customer Service Team For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line Whenever you call have the model and serial number of the appliance ready The serial number and rating labels are inside the grate inside the door Dacor Customer ...

Page 3: ...ncy or the gas supplier WARNING WARNING NEVER use this appliance as a space heater to heat or warm the room Doing so may result in carbon monoxide poisoning and overheating of the appliance WARNING NEVER cover any slots holes or passages on the inside or outside of the range or cover an entire rack with materials such as aluminum foil Doing so blocks air flow through the oven and may cause carbon ...

Page 4: ...h other parts of the range Do not store items of interest to children on top of or above the range Children could be burned or injured while climbing on the appliance Do not attempt to use this appliance in the event of a power failure Clean the cooktop thoroughly before operating it for the first time Keep flammable items such as paper cardboard plastic and cloth away from the burners and other h...

Page 5: ...on box or A 3 wire conduit where local code permits not for use with new branch circuit installations connected to a 3 wire junction box Suggested wiring color code black white red and green Using an appliance cord A 4 wire appliance cord equipped with a NEMA 14 50P plug connected to a NEMA 14 50R receptacle or A 3 wire appliance cord where local code permits equipped with a NEMA 10 50P plug conne...

Page 6: ...23 1 NFPA 54 Be certain that the appliance being installed is correct for the gas service provided natural gas or LP gas Also if operating the range at an altitude above 4000 ft 1219 m make sure it is equipped for high altitude operation Refer to the range rating label and the table on the inside cover to determine the correct model See the table to the right for gas supply pressure requirements T...

Page 7: ...t vent top cap and range IMPORTANT Cabinet face must not stick out further than back of control panel Back of control panel ERV36 ER or ERV48 ER downdraft vent DYRP36DS or DYRP48DS Range 3 8 min 1 0 cm space behind doendraft vent chassis to clear stiffener 3 8 min 1 0 cm flat countertop overhang required behind cutout 29 7 8 75 9 cm Countertop height 36 3 16 91 9 cm min 37 1 2 95 3 cm max Product ...

Page 8: ...n the range is in place The gas supply piping and shut off valve and the electrical junction box receptacle must be located so they do not interfere with the range when it is installed The junction box and gas shut off valve must be located so that the range can be pulled out for service while the appliance remains connected Note 2 F G 2 Cabinet countertop depth is at discretion of customer but ca...

Page 9: ...range itself Installing a Backguard Optional Install the backguard before making the range gas and electrical connections Install it according the installation instructions included with the backguard kit Approved backguard kits Model Description APB36D3 3 inch high backguard for range model DYRP36DS APB36D9 9 inch high backguard for range model DYRP36DS APB48D3 3 inch high backguard for range mod...

Page 10: ...to wood slab for wood is 3 8 1 cm and 5 8 1 6 cm for concrete See SCREW SIZE TABLE to select the correct screw size Attaching the bracket to a concrete floor Drill four 4 3 8 diameter countersink holes through any existing floor covering down to the concrete slab below Drill the 4 holes for the anchors 1 1 4 3 2 cm deep into the concrete slab using a 3 16 masonry bit This hole length is longer tha...

Page 11: ...nsions on page 5 and the actual cabinet cutout dimensions used for the installation Determine and mark the required position of the anti tip bracket based on the diagram above Push the bracket up against the wall in the mounting location Using a pencil make a dot next to the notches on both sides of the bracket Determine if the base plate is as high at the notches by drilling test holes into the w...

Page 12: ...cover unless instructed to do so Make sure that the conduit or appliance cord is long enough to allow the range to be pulled out for service without disconnecting it from power For safety replace the electrical access cover after connecting the wiring Put slack in electrical wiring and gas line Back of range Electrical access cover Removing the Oven Door WARNING Do not attempt to disengage the hin...

Page 13: ...relief not included 4 Slide the wires and the end of the strain relief into the hole on the bottom of the range electrical box 5 Before connecting the wires slide the strain relief nut over the wires and thread it onto the conduit strain relief inside the box Tighten into place 6 Connect the white wire to the neutral terminal in the box 7 Connect the black wire to the L1 power supply terminal 8 Co...

Page 14: ...wire in the junction box 3 Connect the black wire from the appliance to the black L1 power supply wire in the junction box 4 Connect the red wire from the appliance to the red L2 power supply wire in the junction box 5 If using a 4 wire connection connect the green wire to a grounded supply wire in the junction box or to a grounded cold water pipe If connecting to a grounded cold water pipe Use a ...

Page 15: ...n clamp tightly on pipe Wire nut 4 places Bare metal Metal water pipe Clamps Junction box 4 Wire Conduit Connection to Junction Box with External Ground Insulated Pipe Jumper Connection to appliance Page 11 Separate No 10 minimum copper grounding wire No 4 copper wire ...

Page 16: ... 5 Slide the end of the appliance cord into the strain relief from the bottom of the box 6 Connect the white neutral wire to the neutral terminal in the box 7 Connect the L1 wire to the L1 power supply terminal in the box 8 Connect the L2 wire to the L2 power supply terminal in the box 9 If using a 4 wire connection connect the ground wire to the grounding screw inside the box using a loop or spad...

Page 17: ...gas pressure regulator is pre set at the factory for the type of gas intended for use with the appliance To verify that the appliance is compatible with the type of gas available check the range rating label see page II for location Ranges intended for use with LP gas will have LP as a part of the model number Consult your dealer if the range is not compatible with the type of gas supplied Before ...

Page 18: ...tch on the bottom of each hinge rests on top of the lower lip of each hinge receptacle before attempting to open the oven door Rotate the hinge locks toward the front of the range immediately after installation of the door 1 Grasp the oven door on opposite sides and hold it at a 15 angle from the front of the oven Slide the hinges into the hinge openings resting the bottom of the hinge arms on the...

Page 19: ...d with the range The knobs for the center burners are marked with the maximum griddle settings NOTE When installing the knobs align the D shaped opening on the back of the knob with the end of the valve shaft Carefully push the knob on until it stops There are two 2 different types of knobs supplied with the range The knobs for the center burners have the words MAX GRIDDLE on them Icons on Center ...

Page 20: ... pieces are properly seated Gently set the grates on top of the spill tray Put the legs of each grate inside the corresponding dimples SimmerSear Burner Installation Standard Burner Installation STEP 1 Install burner head Put locating tab in keyed hole STEP 1 Put burner ring on top of head STEP 2 Install burner ring Line up ring tabs with head slots STEP 2 Turn ring until it drops into place STEP ...

Page 21: ...r burner ignition test 4 If the appliance still does not work contact Dacor Distinctive Service at 800 793 0093 ex 2822 Do not attempt to repair the appliance yourself Have the model and serial numbers available when you call See page II for location Dacor is not responsible for the cost of correcting problems caused by a faulty installation Removing the Range for Service 1 Turn the gas supply val...

Page 22: ...Dacor 14425 Clark Avenue City of Industry CA 91745 Phone 800 793 0093 Fax 626 403 3130 www dacor com ...

Reviews: