7
Preparing for Installation
WARNING
•
If the gas or electric service provided does not meet the
product specifications, do not proceed with the installation.
Call the dealer, the gas supplier or a licensed electrician.
•
Before installing the range, you must locate and secure the
anti-tip bracket to the floor.
IMPORTANT:
Within the Commonwealth of Massachusetts, this
appliance must be installed by a licensed plumber or gas fitter.
Unpacking the Range
Unpack the parts box and verify that all required components
have been provided. If any item is missing or damaged, please
contact your dealer immediately. Do not install a damaged or
incomplete appliance.
Installation Instructions
Parts List
- 3 Grates
- 8 Standard burner caps
(4 brass, 4 porcelain)*
- 4 Standard burner rings
- 4 SimmerSear burner caps
(2 brass, 2 porcelain)*
- 2 SimmerSear burner rings
- 2 SimmerSear burner heads
- 2 GlideRack™ oven racks
- 1 Standard rack
- 2 GlideRack™ 18” wide oven
racks (DYRP48D only)
- 1 18” wide standard oven rack
(DYRP48DS only)
- 6 Knobs (4 Standard,
2 MAX GRIDDLE)
- Anti-tip bracket with screws
and anchors
- Meat probe
- Griddle
- Wok ring
- Stainless steel cleaner
- Literature kit
- Broiler pan/grill
*The range is supplied with two different types of burner caps
(brass and porcelain) to suit the customer’s preference.
Installing a Downdraft Vent (Optional)
Install the downdraft vent before installing the range. See the
installation instructions included with the downdraft vent.
IMPORTANT
: The downdraft vent attaches to the narrow back
portion of the cutout. It is self-supporting in the cutout and does
not actually attach to the range itself.
Installing a Backguard (Optional)
Install the backguard before making the range gas and electrical
connections. Install it according the installation instructions
included with the backguard kit.
Approved backguard kits:
Model
Description
APB36D3
3 inch high backguard for range model DYRP36D
APB36D9
9 inch high backguard for range model DYRP36D
APB48D3
3 inch high backguard for range model DYRP48D
APB48D9
9 inch high backguard for range model DYRP48D
Install the Anti-Tip Bracket and Foot
Locate the anti-tip bracket included in the parts box.
There are two ways to mount the anti-tip bracket:
•
Floor mounting (preferred method)
•
Wall mounting (alternate method). Use this method if floor
mounting is not suitable. If the front panel of range is further
than 26 1/2” (67.3 cm) from the back wall or if the flooring is
too thick (see
Installing the Anti-Tip Bracket on the Wall
),
the wall mounting method may not be used and the floor
mounting method must be suitable.
Installing the Anti-Tip Bracket on the Floor
WARNING
To perform its intended function, the anti-tip bracket must be
attached as instructed to the concrete slab or wood sub-floor
below any floor coverings (including cement board) on top. Do
not attach the anti-tip bracket directly to floor coverings such as
ceramic/asphalt tile or linoleum.
Four (4) plastic anchors are provided along with three sizes (4
each) of #8 or #12 Phillips head screws for attaching the anti-
tip bracket to the floor. Use both the anchors and four (4) of the
screws when attaching the bracket to a concrete sub-floor. Do not
use the provided anchors when attaching to a wood sub-floor.
continued...
Sub-floor
Screws attached to
sub-floor below floor
covering
Anti-tip
bracket
Floor
covering
Concrete anchors shown, do
not use for wood sub-floor