Dacor DHW301 Installation Instructions Manual Download Page 8

6

Installing the Mounting Bracket 

(Continued)

Locate the verti-

3. 

cal center line for 

the hood mount-

ing location on 

the wall. Mark the 

center line with a 

six inch vertical 

line that intersects 

the line drawn in 

step 2.
Make sure the 

4. 

mounting location 

is properly rein-

forced so that it 

will hold the weight 

of the hood.
Find the mounting bracket in the shipping box. Place 

5. 

it against the wall where the two lines cross. Center 

it vertically and line the top of the bracket up with the 

horizontal line as shown.

Making sure the bracket is level, use a pencil to 

6. 

mark the mounting hole locations through the bracket 

holes.
Drill the mounting holes. The method for drilling the 

7. 

holes depends on the type of mounting surface...

if mounting the hood to brick or masonry:

Drill three 5/16” x 1 1/2” holes in the locations 

 

marked.

Insert three of the provided wall anchors into the 

 

holes. The anchors provided are for attaching the 

hood to masonry or brick only.

if mounting the hood to drywall:

Drill three appropriate sized pilot holes for the 

 

mounting hardware being used. The drywall 

mounting hardware must be purchased sepa-

rately.

Attach the mounting bracket securely to the wall.

8. 

Installing Chimney Mounting 

Bracket

Locate the chimney mounting bracket and position it 

1. 

against the ceiling as shown. Center it on the hood 

center line.
Mark the ceiling and the wall in two places each, 

2. 

through the holes in the bracket. 
Drill four 5/16” holes through the four spots marked 

3. 

on the ceiling and wall.
Insert the four of the provided wall anchors into the 

4. 

four holes on the ceiling and wall.
Attach the chimney mounting bracket using four 

5. 

included 1 1/2” screws.

Installation Instructions

Mounting 

bracket

Anchors

Chimney 

mounting bracket

CL

CL

Hood center 

line

Height of 

mounting 

bracket 

(step 2)

CL

CL

Line up  

center hole with 

center line

Line horizontal 

line up with this 

edge

Mounting 

bracket

Anchor

Summary of Contents for DHW301

Page 1: ...Installation Instructions Millennia Wall Mount Range Hoods Models DHW301 DHW361 DHW421 and DHW482 Part No 101743 Rev F Approved for use with all dacor ranges and cooktops...

Page 2: ...ore you begin the installation process Leave these installation instructions with the customer Customer Keep these installation instructions for future reference and the local electrical inspector s u...

Page 3: ...G Use this unit only in the manner intended by the manufacturer If you have questions contact the a manufacturer Before servicing or cleaning unit switch power off at service panel and lock the servic...

Page 4: ...with the controls If the range or cooktop and range hood are near a window use an appropriate window treatment Avoid long drapes or other window coverings that could blow over the cooktop and hood re...

Page 5: ...s Blower Speeds 4 with electronic speed control Lights 12 Vac 20 Watt halogen Filters Baffle type dishwasher safe Exhaust 8 inch Finish 430 stainless steel Total Connected Load 120 Vac 60 Hz See table...

Page 6: ...the duct weight To prevent back drafts a damper at the duct outlet may also be required Make sure duct work does not interfere with floor joists or wall studs Installation Specifications Calculating t...

Page 7: ...roper installation before proceeding Hood assembly with filter s Chimney assembly 2 piece Chimney mounting bracket Mounting bracket Blower exhaust cowling 2 blower units only Mounting and assembly har...

Page 8: ...wall anchors into the holes The anchors provided are for attaching the hood to masonry or brick only If mounting the hood to drywall Drill three appropriate sized pilot holes for the mounting hardware...

Page 9: ...they make contact with the bracket then tighten them as necessary to make minor leveling adjustments to the hood Insert two machine screws through the front of the 5 mounting bracket and tighten them...

Page 10: ...nnect the hood ground wire to a separate proper ground wire installed by a licensed electrician Make sure all wire used is capable of handling the total connected load See page 3 Connect the house pow...

Page 11: ...d the blower key until the blower 8 turns off If the hood fails to operate properly Verify that power is supplied to the hood Check the electrical connections to ensure that the installation has been...

Page 12: ...however all wires are coded and the connections on the PC Board are also coded with the same number letters MAIN POWER SWITCH TRANSFORMER EXTERNAL BLOWER CONNECTION TRANSFORMER TO BLOWER MOTOR YELLOW...

Page 13: ...however all wires are coded and the connections on the PC Board are also coded with the same number letters MAIN POWER SWITCH YELLOW GREEN EXTERNAL BLOWER CONNECTION TRANSFORMER TRANSFORMER TO BLOWER...

Page 14: ...12 Notes...

Page 15: ......

Page 16: ...Dacor 600 Anton Blvd Suite 1000 Costa Mesa CA 92626 Phone 800 793 0093 Fax 626 403 3130 www Dacor com...