background image

Quick Start Guide

1.

Unpack telephone, you have been supplied with:

Ÿ

RA711-GSM Telephone

Ÿ

Mains power pack 12V DC 2A

 (optional)

Ÿ

GSM Antenna

 (optional)

2.

Insert valid SIM card into telephone SIM holder

3.

Connect 

a

ntenna ensuring instructions are followed on page 3 [Electrical connection]

4.

Connect power supply [telephone will take up to 3 minutes to initially connect to network,

 

however this normally occurs in less than 

60

 seconds]

5.

At this stage you can call the telephone [telephone number determined by SIM card], however

 

the telephone will not dial out until a number is stored in the internal memory.

6.

If required, store a number in the internal memory by utilising the CVC [Configure Voice Call]

 

command. Send a text message to the telephone as follows:

C44XXXXXXXXX

You will receive a message back from the telephone confirming that you have configured 

the

 

voice call number.

When the telephone is operated [call button is pressed] it will now dial the telephone number you

 

have stored in the memory.

Ensure you send text message with full stop and country code [as 
written

 

here] followed by valid telephone number

Summary of Contents for RA711-GSM

Page 1: ...DAC LIMITED USER GUIDE RA711 GSM ...

Page 2: ...Contents 1 Introduction 2 Mounting Options 3 Electrical Connection 4 Operation 4 SMS Configuration and Status Reporting 5 Commands 11 Quick Start Guide 12 General Care and Maintenance ...

Page 3: ...M Network 3G or 4G The RA711 GSM telephone is supplied SIM free allowing the user customer to select any mobile network operator as their preferred carrier This user guide is designed to assist with the operation of the RA711 GSM 3G 4G provide simple installation instructions and explain the various programming and reporting parameters available If you require more detailed technical information p...

Page 4: ...Top of Pole Mounting Top of pole mounting bracket Part No 552642 available from DAC Limited Wall Mounting Inset Flush mounting using In Wall Box Part No RA711 IW or Surface mounting using rear enclosure Part No RA711 OW ...

Page 5: ... consumption will be dependant on usage please consult with your supplier for advice concerning suitable power options for your particular application The HOOK LED indicator should be OFF when the telephone is ON HOOK and should be ON when the telephone is OFF HOOK During incoming ringing the LED will flash slowly and if a FAST FLASH is observed this indicates that the telephone is NOT registered ...

Page 6: ...d remotely by using SMS Short Message Service text messages containing correctly formatted commands Incoming command texts allow various parameters to be configured and outgoing log texts can provide log reports regarding the telephone status The messages are sent and received via standard GSM mobile devices mobile telephones and are displayed as standard text messages Typical command parameters w...

Page 7: ...x 37mV Signal GSM Signal_level Range is 0 31 0 unregistered 31 max strength Last Call Duration of last call if over 10 seconds Ver Firmware _Version Factory preset Configure or change USERTEXT recipients CTX In order to configure the USERTEXT recipients person s who receives notification of parame ter change or system error the telephone will require data input via SMS using the CTX command Up to ...

Page 8: ...ocation of telephone this can be configured via SMS Type New VOICE No s set Battery Battery_voltage current battery voltage e g 11 95V accurate to approx 37mV Signal GSM Signal_level Range is 0 31 0 unregistered 31 max strength Last Call Duration of last call if over 10 seconds Ver Firmware _Version Factory preset Configure Location command CLO Each telephone can be programmed with its own unique ...

Page 9: ...nge is 0 31 0 unregistered 31 max strength Last Call Duration of last call if over 10 seconds Ver Firmware _Version Factory preset Status request command REQ In order to clarify telephone status a request can be made to establish system parameters and health status Upon receipt the telephone replies with a USERTEXT message to the command originator REQ1234 The originator the person who sent the SM...

Page 10: ...nfigure Command Configure Parameters Command CFG This describes the parameters that can be configured monitored and should only be used following consultation with your supplier or with DAC Limited direct IO 1 2 output 0 relay off 1 relay on Auto answer after this number of network RING indicators 0 25 00 off Auto on hook time minutes 0 20 00 off Handset volume 0 5 5 highest Handsfree volume 0 5 5...

Page 11: ...l the telephone telephone number determined by SIM card however the telephone will not dial out until a number is stored in the internal memory 6 If required store a number in the internal memory by utilising the CVC Configure Voice Call command Send a text message to the telephone as follows CVC1234 44XXXXXXXXX You will receive a message back from the telephone confirming that you have configured...

Page 12: ...maintenance To clean wipe with a damp cloth Do not use any abrasive cleaners on the telephone as this may cause the telephone to become discoloured DISTRIBUTED BY DAC Limited Union Mill Watt Street Sabden Lancashire BB7 9ED Tel 01282 447000 Fax 0845 280 1915 www daclimited co uk ...

Reviews: