Recommendations for preserving the equipment

Your  Dabi  Atlante  equipment  has  been  designed  and  developed  according  to  the  standards  of 

modern techology. Similarly to other kinds of equipment, it requires special care, which is many times 

neglected due to several reasons and circunstances. Therefore, here are some important reminders

for your daily routine. Try to follow these simple rules, which will save you a lot of time and will 

avoid unnecessary expenses once they start making part of your working procedure.

Transportation, storage and operation

This equipment must be transported and stored observing the following directions:

- Avoid falls and impacts;

- Keep it dry, do not expose it to rain, water drops or wet floor;

- Keep it away from water and direct sunlight, and in it original wrapping;

- Don’t move it over irregular surfaces, protect it from rain and observe the maximum stack quantity

specified in the packaging;

Environmental condition for transportation or storage:

- Room temperature range for transportation or storage -29ºC to +60ºC.

- Relative humidity range for transportation or storage 20% to 90%.

- Atmospheric pressure range 500hPa to 1060 hPa (375 mmHg to 795 mmHg).

Environmental operation condition:

- Room temperature range for funct10ºC to +40ºC.

- Recommended room temperature range +21ºC to +26ºC.

- Relative humidity range for functioning 30% to 75%.

- Atmospheric pressure range 700 hPa to 1060 hPa (525 mmHg to 795 mmHg).

- Operation altitude: ≤2000m.

PRECAUTIONS, RESTRICTIONS AND WARNINGS

ATTENTION 

The Equipment maintains its condition of safety and efficacy, provided that it is maintained (stored) 

as mentioned in this instruction of use. Thus, the equipment will not lose or alter its physical and 

dimensional features. 

Sensibility to predictable environmental conditions in regular use conditions

The  equipment  has  been  planned  not  to  be  sensitive  to  interference  such  as  magnetic  fields, 

external electrical factors, electrostatic discharge, pressure or variance of pressure, provided that 

the  equipment  is  installed,  maintained,  clean,  preserved,  transported  and  operated  as  per  this 

instruction for use.

Precautions and warnings “during the use” of equipment

- The equipment should only be operated by duly enabled and trained technicians (Dental Surgeons,

Capacitated Professionals).

-  Before  the  first  use  and/or  after  long  interruptions  from  work  such  as  vacations,  clean  and 

disinfect the equipment.

- If any maintenance should be required, only use services of the Dabi Atlante Authorized  Technical 

Assistance.

- Owing to its delicate components, this handpiece must not be dropped or undergo impacts.

- Although this equipment has been planned in accordance with the standards of electromagnetic 

compatibility, it can, in very extreme conditions, cause interference with other equipment. Do not 

use this equipment together with other devices very sensitive to interference or with devices which 

Summary of Contents for MICRO MOTOR INTRA 32MM C SPRAY TB

Page 1: ......

Page 2: ...ICRO MOTOR INTRA SL 30 TM SI Brand Dabi Atlante Manufacturer Distribuitor Alliage S A Ind strias M dico Odontol gica C N P J 55 979 736 0001 45 Insc Est 582 002 897 114 Rod Abr o Assed Km 53 450m Cx P...

Page 3: ...ntal conditions in regular use conditions 12 Precautions and warnings during the use of equipment 13 Precautions and warnings after the use of equipment 13 Precautions in case of alteration in the fun...

Page 4: ...RAY TB MICRO MOTOR INTRA SL 30 C SPRAY TM MICRO MOTOR INTRA SL 30 S SPRAY TB MICRO MOTOR INTRA SL 30 TB SI MICRO MOTOR INTRA SL 30 TM SI Brand Dabi Atlante Indication of Equipment This equipment is fo...

Page 5: ...ocedures With a design which caters for ergonomics torque sensitivity and lightness Produced with technology MADE IN BRAZIL and material of the utmost durability Internal irrigation System according t...

Page 6: ...ng and accessories Optional MODULES ACCESSORIES OPTIONSANDMATERIALSOFCONSUMPTION External Spray Irrigation System Terminal type BORDEN Terminal type MIDWEST Internal Spray Irrigation System 01 c c c 0...

Page 7: ...ERIALSOFCONSUMPTION 01 02 03 Optional 01 Coupling lining TB TM 02 O ring 03 Lubricant Lubs Attention The use of any part accessory or material not speci ed or foreseen in these instructions for use is...

Page 8: ...ype 04 holes Coupling via the INTRA system Straight Piece and Contra Angle Sterilization Autoclavable up to 135 C TECHNICAL SPECIFICATIONS General features Weight Model Net Weight Gross Weight 32 MM 7...

Page 9: ...e the manual Borden Type Terminal It determines the maximum quantity of boxes which can be stacked during transportation and storage as per packaging Packing to be transported and or stored avoiding h...

Page 10: ...10 Midwest Type Terminal Midwest type Terminal Optical Fiber LED UV LED lighting TECHNICAL SPECIFICATIONS Dimensions mm BORDEN TYPE TERMINAL WITH SPRAY MIDWEST TYPE TERMINAL WITH SPRAY...

Page 11: ...ed Dirty and moist air lead to premature wear of the bearings For the handpiece to function well it is necessary to have a driving pressure of 275 79 kpa 40 psi 2 75 bar Ring lock unlock Ring lock unl...

Page 12: ...nctioning 30 to 75 Atmospheric pressure range 700 hPa to 1060 hPa 525 mmHg to 795 mmHg Operation altitude 2000m PRECAUTIONS RESTRICTIONS AND WARNINGS ATTENTION The Equipment maintains its condition of...

Page 13: ...mination or undue use of the Equipment after it has become useless it should be discarded in the suitable place as per the local legislation of the country Pay attention to the local legislation of th...

Page 14: ...he holes aligned an with a screwdriver push the lining carefully downwards fig c Maintenance of the MIDWEST Type Lining Use the same procedure as the BORDEN type Maintenance of O Ring Change Insert a...

Page 15: ...motor as illustrated in fig a Firmly fit the oil applicator nozzle into the hole indicated in fig a and apply the spray for 1 or 2 seconds fig b by holding the vial in vertical position Perform these...

Page 16: ...e Maintenance Dabi Atlante states that the supplying of the circuits diagram Part lists or any other information that permits the technical assistance by the user can be requested since previously agr...

Page 17: ...the instructions below to check and repair the problem and or get in touch with your representative FINAL CONSIDERATIONS Among the care you have to take with your equipment the most important is rega...

Page 18: ...18...

Page 19: ...19...

Page 20: ......

Reviews: