ENGLISH
9
6. RESPONSIBILITY
The Manufacturer does not vouch for correct operation of the panel if it is tampered with or modified, or made
to operate above the values indicated on the data plate.
The Manufacturer declines all responsibility for possible errors in this booklet, if due to misprints or errors in
copying. The company reserves the right to make any modifications to products that it may consider necessary
or useful, without affecting the essential characteristics.
7.
PRECAUTIONS FOR THE BATTERY HOUSED IN THE CONTROL UNIT
Do not cause sparks or flames above or around the battery.
Do not short-circuit the terminals.
Never open the battery or throw it in the fire.
If the electrolyte (diluted sulphuric acid) comes in contact with the skin or clothes, wash immediately with
water. If it comes in contact with the eyes, wash them and consult a doctor.
Inspect the outside of the battery and change it if you find any breakage, swelling or other damage to the
container or cover of the battery.
Clean any dust or other dirt off the battery before use.
At the end of the battery's working life, do not throw it out with the ordinary refuse, but take it to an
approved collecting centre.
8.
USE IN PARTICULAR ENVIRONMENTAL CONDITIONS
If installed in the open, the panels must be protected as much as possible against direct sunlight. If necessary,
suitable steps must be taken to keep the internal temperature of the panel within the above-mentioned field of
use. High temperatures lead to rapid ageing of all the components, causing more or less severe malfunctions.
9. TECHNICAL
DATA
Rated input voltage:
115-220-240V ± 10%
Phases:
1
Frequency:
50-60 Hz
Consumption:
7VA 220-240V
Operating time:
12 hours
Sound volume:
95dB discontinuous
Contacts:
5A 250V
Field of use environment temp.:
-10°C +40°C
Storage environment temp. limit:
-20°C +40°C
Degree of protection:
IP 30
10. KEY
REF. DESCRIPTION
10
Live (red warning light)
13
Control unit protection fuse
14
Spare fuse
16
Siren silencing button
17
Siren
18
Maximum water level and low battery charge below the limit (red warning light)
19
Button for blocking the electronic circuits, to be pressed at the end of battery recharging; the
batteries of control units in store must be recharged every six months. To press, use a screwdriver.
A
Command signal: input with voltage 12V d.c. 10 mA for connecting the maximum level float
(standard supply) or a pressure switch, flow switch or other switch. Maximum admissible
resistance for the control circuit <300
.
B
Remote signal (output signal): usable for remote operation of acoustic or luminous alarms due to
the intervention of the maximum level float. Contact characteristics: contact without potential 5A
- 250V.