DAB DLM-12A User Manual Download Page 5

 

  

 

 

   

 

DLM-12A / DLM-12SA 

Ordercode: D3223 / D3224  

Connection with the mains 

 
Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

FASE 

BLUE 

BLACK 

SILVER 

NULL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 

Make sure that the device is always connected 

properly 

to the earth! 

 
Improper installation can cause serious damage to people and property! 

 

 
Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms 
 

Claims 

 
The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 
 

 

Summary of Contents for DLM-12A

Page 1: ...DLM 12A DLM 12SA Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode D3223 D3224 MANUAL ENGLISH ...

Page 2: ...s 4 Features 5 Rear Panel DLM 12A 6 Rear Panel DLM 12SA 7 Connection Examples 8 Two Active Satellite Speakers 8 Active full range multiple speakers 9 Two Active Subwoofers Two Active Satellite Speakers 10 One Active Subwoofer Two Active Satellite Speakers 11 Frequency Response Diagram 12 Connection Cables 13 Technical Specifications 14 Troubleshooting 14 Dimensions 0 ...

Page 3: ...ing to qualified technicians only IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the system Always disconnect power from the mains when system is not used Only handle the power cord by the plug Never pull out the plug by tugging the power cord Always operate the unit with the AC ground w...

Page 4: ... on all sides of the system for air circulation Make sure you don t use the wrong kind of cables or defective cables Make sure you use DI boxes to balance unbalanced signals All incoming signals should be clear Never let the power cord come into contact with other cables Handle the power cord and all connections with the mains with particular caution Never remove warning or informative labels from...

Page 5: ...roper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects ...

Page 6: ...d built in DSP protection system it is almost impossible to deform your sound when used normally High end components including a CELESTION high driver gives lots of sound pressure and a very high detailed sound If you want to have a more personalized sound this is no problem for the DLM Just add the optional USB control module and now it is possible to adjust the Gain Equalizer Low High pass filte...

Page 7: ...connector INPUT 2 accepts Hi Z sources such as guitars via the TRS 1 4 Input or line level signal via XlR RCA Inputs Input 2 Signal Limit LED Power LED Normal User DSP processing 2 presets switch Input 1 MIX switch This switch allows you to choose whether only the Input 1 signal is sent out to the next loudspeaker or the mix of the input 1 and input 2 are sent out to the next loudspeaker Thru outp...

Page 8: ...Polarity Stereo Mono switch Full range Input channel A XLR Highpass output channel A XLR Fullrange output channel A XLR Input channel B XLR Highpass output channel B XLR Fullrange output channel B XLR Volume control power amplifier Signal Limit LED Normal User DSP processing 2 presets switch Power LED DLM USB DSP module D3226 Optional accessory ...

Page 9: ... your audio mixer into OUTPUT LEFT RIGHT and the other side of the cable into the LINE INPUT Combo of your active satellite speakers 3 Connect the power cords to main 4 Turn on your mixer first then the active speaker cabinets 5 Turn up the volume controls of the active speaker cabinets 6 Use PFL function to get the proper input level for the mixer and adjust the Main Mix Level 7 After using your ...

Page 10: ...ferent zones like in a Bar Pub Restaurant Church etc Each DLM cabinet has its own volume control so you can adjust different volumes in different zones 1 Follow the steps connecting the MAIN OUTPUTS of the mixer to the LINE INPUTS of two DLM active cabinets 2 Connect the THRU socket of the first DLM cabinet to the LINE INPUTS socket of the subsequent piece You can connect as many speakers as you w...

Page 11: ...no input of your active DLM subwoofers 3 Connect one side of another signal cable at your active subwoofers into the HIGHPASS Output and the other side of the cable into the LINE INPUT COMBO of your active satellite speakers 4 Connect the power cords to main 5 Turn on your mixer first then the active speaker cabinets 6 Turn up the volume controls of the active speaker cabinets 7 Use PFL function t...

Page 12: ...of the DLM active subwoofer Repeat for the channel With the second signal cable connected the HIGHPASS A of the subwoofer input BXLR to the Line input COMBO of the active satellite with Stereo Jack or XLR Repeat for the RIGHT channel 4 Connect the power cords to main 5 Turn on your mixer first then the active speaker cabinets 6 Turn up the volume controls of the active speaker cabinets 7 Use PFL f...

Page 13: ...12 DLM 12A DLM 12SA Ordercode D3223 D3224 Frequency Response Diagram ...

Page 14: ...asing their life and reliability Periodically check your cables A great number of problems faulty contacts ground hum discharges etc are caused entirely by using unsuitable or faulty cables Unbalanced Balanced For these applications the unit provides 1 4 TRS and XLR connectors to easily interface with most professional audio devices Follow the configuration examples below for your particular conne...

Page 15: ...ocessor Digital Presets NORMAL USER Frequency response 35Hz 200Hz 10dB Max SPL 1m 128dB Power Amp High power Class D 1000W Inputs Female XLR balanced differential stereo left right Input level Line 4dBu Full range Output Male XLR balanced High Pass Output Male XLR balanced USB Control optional Gain EQ Trim high pass filter and low pass filter and bandpass filter External Control Volume Control Ele...

Page 16: ...Dimensions DLM 12A DLM 12SA 2014 DAP Audio ...

Reviews: