TENSIONED COSMOPOLITAN

®

  ELECTROL

®

  INSTALLATION

120V WIRING DIAGRAM 

WITH OPTIONAL BUILT-IN 

LOW VOLTAGE CONTROL

GROUND–MUST BE 

CONNECTED TO 

BUILDING GROUND

RJ-14 PIN-OUTS

(TAB IS FACING UP)

IMPORTANT NOTE:

 

The wall switch is REQUIRED to make any limit switch 

adjustments, EVEN if a third party control system is 

used.  Therefore, it is advised to wire the switch or 

provide a 3-conductor connection that is accessible.

UP

STOP

DOWN

POWER INPUT 120VAC / 60HZ

GREEN (GROUND)

BLACK (HOT)

WHITE (COMMON)

POWER WIRE

DATA

CABLE

RJ-45 JACK

RJ-45

RECEPTACLE

RJ-22

OUTPUT

RJ-22

JACK 

RJ-22

INPUTS

RJ-22

JACK

LED

UP LIMIT 

TACTILE 

BUTTON

DOWN LIMIT 

TACTILE 

BUTTON

FRONT OF 

WALL SWITCH

BACK OF

WALL SWITCH

RJ-22 PIN-OUTS

(TAB IS FACING UP)

RJ-45 PIN-OUTS

(TAB IS FACING UP)

Standard RJ-22 can be used in place of RJ-14

Supplied RJ-14 cable

BLUE
YELLOW
GREEN
RED
BLACK
WHITE

+12V

BUS (RP DATA)

RQ DATA

+5V

GND

RQ CLOCK

BUS (RP DATA)

RQ DATA

+5V

GND

WHITE
GREEN
RED
BLACK

BLUE
YELLOW
GREEN
RED
BLACK
ORANGE

BROWN

PURPLE

+12V

BUS (RP DATA)

RQ DATA

+5V

GND

RQ CLOCK

MANUAL 1

MANUAL 2

DRY CONTACTS

120V WIRING DIAGRAM WITH  

OPTIONAL BUILT-IN VIDEO  

PROJECTOR INTERFACE

5/12 VOLT SCREEN 

TRIGGER ON PROJECTOR

CAUTION: THE PROJECTOR MUST BE TURNED OFF BEFORE CONNECTING THE 
TRIGGER WIRES TO THE PROJECTOR. FAILURE TO DO SO MAY DAMAGE THE 
CONTROLLER.

 Use 2-conductor 20-24 gauge wire to extend the low voltage connection 
from the projector’s 5 or 12-volt screen trigger output to the length 
required to reach the VPI. When extending the low voltage connection 
from the projector’s screen trigger output polarity does not matter. The 
red and black wires from the VPI are interchangeable. 

GROUND–MUST BE CONNECTED 

TO BUILDING GROUND

UP

STOP

DOWN

POWER INPUT 120VAC / 60HZ

GREEN (GROUND)

BLACK (HOT)

WHITE (COMMON)

POWER 

WIRE

DATA

CABLE

RJ-45 

JACK

RJ-45

RECEPTACLE

RJ-22 OUTPUT 

RJ-22 JACK

RJ-22

INPUTS

RJ-22

JACK

LED

UP LIMIT

TACTILE 

BUTTON

DOWN 

LIMIT

TACTILE 

BUTTON

FRONT OF 

WALL SWITCH

BACK OF

WALL SWITCH

BLACK 

RED

VPI TRIGGER 

MODULE

IMPORTANT NOTE:

 

The wall switch is REQUIRED to make any limit switch adjustments, 
EVEN if a third party control system is used.  Therefore, it is advised to 
wire the switch or provide a 3-conductor connection that is accessible.

3-conductor 20-24 gauge wire can be used in place of the supplied RJ-14 
cable to connect the wall switch.  Connect the BUS terminals on the wall 
switch to the corresponding BUS terminals on the splitter board.

UP

DOWN

COMMON

BUS

5V

BUS

BUS

COM 5V

BUS

3-conductor 20-24 gauge wire can be used in place of 

the supplied RJ-14 cable to connect the wall switch.  

Connect the BUS terminals on the wall switch to the 

corresponding BUS terminals on the splitter board.

DRY CONTACTS

UP

DOWN

COMMON

BUS

5V

BUS

BUS

COM

5V

BUS

Summary of Contents for Tensioned Cosmopolitan electrol

Page 1: ...st Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 Toll Free Fax 877 325 4832 www da lite com e mail info da lite com Instruction Book for Tensioned Cosmopolitan Electrol For Sizes UpTo 10 x10 The Da Lite Difference ...

Page 2: ...completely sealed in recessed installation Allow access for service Picture surface is centered in case Case extends 5 1 2 beyond surface on either end Do not attach anything to screen slat rod or bottom fabric pocket 1 Make sure screen is level Use a carpenter s level and plumb level CAUTION Do not cut wrapping paper or tape with knife or any sharp tool Remove by hand 2 Install electrical hook up...

Page 3: ...SWITCH AND BOX THIS SWITCH CANNOT BE USED WITH LVC NOTE A single switch cannot be used to operate more than one screen Contact the factory for further information DOWN BLACK BLACK UP WHITE RED DOWN AC HOT OFF COMMON WHITE BLACK WITH YELLOW UP RED ROCKER SWITCH AC COMMON 120 V 60 HZ 2 5 MAX AMP 120V WIRING DIAGRAM DOWN WHITE LIMIT SWITCH ADJUSTMENT IN MULTIPLE CONTROL INSTALLATIONS THIS SWITCH IS R...

Page 4: ...r Failure to do so may damage the controller Use 2 conductor 20 24 gauge wire to extend the low voltage connection from the projector s 5 or 12 volt screen trigger output to the length required to reach the VPI When extending the low voltage connection from the projector s screen trigger output polarity does not matter The red and black wires from the VPI are interchangeable GROUND MUST BE CONNECT...

Page 5: ...ll switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 4 conductor connection that is accessible CONNECT SUPPLIED RJ9 CABLE TO SPLITTER AND SWITCH OR USE 4 CABLE CONDUCTOR TO CONNECT TO SCREW TERMINALS The screen surface travel is stopped automatically in the fully opened and closed positions b...

Page 6: ...nt voltage rewire incoming electric line b Replace fuse c Reset circuit breaker d Check above Tighten all loose wire connections Correct any improper connections Down Position Check for power across black and white leads Up Position Check for power across red and white leads e Let motor cool down for 15 minutes Try again f Check for continuity Cut off old splice and reconnect g Replace motor assem...

Page 7: ...6 ...

Page 8: ...e by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY Any implied warranties of fitness for use or merchantability that may be mandated b...