background image

TENSIONED ADVANTAGE

®

 DELUXE ELECTROL

®

 INSTRUCTIONS FOR STANDARD CONTROL

120V WIRING DIAGRAM

SCREEN MOTOR

BLACK (UP)

RED 

(UP)

OPTIONAL RF OR IR 

REMOTE CONNECTOR

WHITE 

(COMMON)

POWER INPUT

120VAC/60HZ

DOOR MOTOR

DOWN

STOP

UP

NOTE: Electrical connections 
on left end of case.

AUX  EYE

 

NOT USED

WHITE

 (COMMON)

NOT USED

NOT USED

WHITE

 (COMMON)

NOTE: 20-24AWG WIRE RECOMMENDED 

FOR CONNECTING WALL SWITCH TO THE 

DUAL MOTOR CONTROLLER

DOOR MICROSWITCH

FRONT OF

WALL SWITCH

BACK OF

WALL SWITCH

BLACK (HOT)

GREEN 

(GROUND)

BLACK (DOWN)

WHITE

 (COMMON)

RED 

(UP)

BLACK (DOWN)

BLACK (DOWN)

WHITE 

(COMMON)

RED 

(UP)

RED 

(DOWN)

WHITE 

(COMMON)

RED 

(UP)

BLACK (DOWN)

GREEN 

(GROUND)

WHITE

 (COMMON)

RED 

(UP)

BLACK (DOWN)

GREEN 

(GROUND)

WHITE

 (COMMON)

RED 

(DOWN)

BLACK (UP)

GREEN 

(GROUND)

WHITE

 (COMMON)

RED 

(DOWN)

BLACK (UP)

GREEN 

(GROUND)

220/240V WIRING DIAGRAM

OPTIONAL RF OR IR 

REMOTE CONNECTOR

POWER INPUT

240VAC/50HZ

NOT USED

NOT USED

NOT USED

DOOR MICROSWITCH

NOTE: 20-24AWG WIRE RECOMMENDED 

FOR CONNECTING WALL SWITCH TO THE 

DUAL MOTOR CONTROLLER

NOTE: Electrical connections 
on left end of case.

AUX  EYE

 

FRONT OF

WALL SWITCH

BACK OF

WALL SWITCH

SCREEN MOTOR

DOOR MOTOR

BLUE 

(COMMON)

BROWN 

(HOT)

GREEN

/

YELLOW

 (GROUND)

DOWN

STOP

UP

RED 

(UP)

BLACK (DOWN)

WHITE

 (COMMON)

WHITE

 (COMMON)

RED 

(UP)

BLACK (DOWN)

BROWN 

(UP)

BROWN 

(DOWN)

BLUE 

(COMMON)

BLACK (UP)

BLACK (DOWN)

BLUE 

(COMMON)

BLUE 

(COMMON)

BLACK (UP)

BROWN 

(DOWN)

GREEN

/

YELLOW

 (GROUND)

BLUE 

(COMMON)

BLACK (UP)

BROWN 

(DOWN)

GREEN

/

YELLOW

 (GROUND)

BLUE 

(COMMON)

BLACK (DOWN)

BROWN 

(UP)

GREEN

/

YELLOW

 (GROUND)

BLUE 

(COMMON)

BLACK (DOWN)

BROWN 

(UP)

GREEN

/

YELLOW

 (GROUND)

3

Summary of Contents for Tensioned Advantage Deluxe Electrol

Page 1: ...Street Post Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 Toll Free Fax 877 325 4832 www da lite com e mail info da lite com Instruction Book for Tensioned Advantage Deluxe Electrol The Da Lite Difference ...

Page 2: ...witch connections is located under the metal housing surrounding the junction box Remove two screws for access 1 Carefully unpack screen and remove outer wrapping from case 2 Make sure to recheck measurements of screen location before installation IMPORTANT SAFETY INSTRUCTIONS When using your video equipment basic safety precautions should always be followed including the following 1 Read and unde...

Page 3: ... 2 Only if the roller assembly is preinstalled 7 Test installation by operating the screen several times Be prepared to stop the screen Standard Duty Cycle 1 MIN ON 3 MIN OFF The fabric door rear door will not close until the wall switch is placed in the up position and when the screen motor stops at its limit switch in the up direction NOTE Excessive continuous operation may cause the motor to ov...

Page 4: ... BLACK DOWN GREEN GROUND WHITE COMMON RED DOWN BLACK UP GREEN GROUND WHITE COMMON RED DOWN BLACK UP GREEN GROUND 220 240V WIRING DIAGRAM OPTIONAL RF OR IR REMOTE CONNECTOR POWER INPUT 240VAC 50HZ NOT USED NOT USED NOT USED DOOR MICROSWITCH NOTE 20 24AWG WIRE RECOMMENDED FOR CONNECTING WALL SWITCH TO THE DUAL MOTOR CONTROLLER NOTE Electrical connections on left end of case AUX EYE FRONT OF WALL SWI...

Page 5: ...OTOR CONTROLLER TENSIONED ADVANTAGE DELUXE ELECTROL INSTRUCTIONS SCB 100 CONTROL POWER INPUT AND CONTROL BOARD ARE LOCATED ON RIGHT SIDE OF SCREEN HOUSING 220 240V WIRING DIAGRAM 120V WIRING DIAGRAM NOTE Electrical connections on right side of case NOTE Electrical connections on right side of case BLACK HOT GREEN GROUND WHITE COMMON POWER INPUT 120VAC 60HZ DOWN STOP UP NOT USED BACK OF FRONT OF WA...

Page 6: ...COMMON B A TENSIONED ADVANTAGE DELUXE ELECTROL INSTRUCTIONS SCB 200 CONTROL POWER INPUT AND CONTROL BOARD ARE LOCATED ON RIGHT SIDE OF SCREEN HOUSING 220 240V WIRING DIAGRAM 120V WIRING DIAGRAM NOTE Electrical connections on right side of case NOTE Electrical connections on right side of case BLACK HOT GREEN GROUND WHITE COMMON POWER INPUT 120VAC 60HZ NOT USED ENCODER 5V A B GND SCREEN MOTOR DOOR ...

Page 7: ...ND ELECTRICAL JUNCTION BOX 7 1 4 7 5 8 9 1 4 SUGGESTED 3 8 THREADED ROD NOT INCLUDED ATTACHED TO MOUNTING BRACKET FINISHED CEILING SELF TRIMMING FLANGE 7 1 4 8 3 4 SEE DETAIL A SUGGESTED 3 8 THREADED ROD NOT INCLUDED 4 59 7 21 8 75 DETAIL A 8 74 HANGER BRACKET Flat bracket Mounting Method formed bracket Mounting Method ...

Page 8: ...sufficient voltage rewire incoming electric line b Replace facility fuse c Reset facility circuit breaker d Check above Tighten all loose wire connections Recheck wiring See installation instructions Down Position Check for power across black and white leads e Let motor cool down for 15 minutes Try again f Check for continuity g Replace motor assembly NOTE Motor is a sealed assembly h Replace moto...

Page 9: ...m screen motor a Down limit switch out of adjustment a Buzzing noise b Gear noise a Defective brake a Pin end slipped out of nylon bearing a Screen not installed properly b Fabric is damaged a Screen up limit out of adjustment a Loose wire Solution a Check installation to free door Clear any foreign substance i e paint or plaster from hinge b See above a Replace switch b Replace screen motor a See...

Page 10: ...9 ...

Page 11: ...10 ...

Page 12: ...le by the purchaser and Da Lite is not responsible for damage in shipment To protect yourself against damage or loss in transit insure the product and prepay all transportation expenses THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANT ABILITY Any implied warranties of fitness for use or merchantability that may be mandated ...

Reviews: