background image

3

MORE SCREEN DROP

1. Place operating switch in 

“down”

position.

2. When the screen stops, turn the white 

“down” 

limit knob (Fig. 2) one-quarter turn counterclockwise. Test by raising

picture surface approximately two feet, then lower again. Repeat until desired picture surface position is attained.

CAUTION: Do not adjust for more drop than what was ordered. At least 1-1/2 wraps of fabric must remain on the roller. This
screen comes standard with 12" black at the top.

LESS SCREEN DROP

1. Raise picture surface approximately two feet above desired level.

2. Place operating switch in 

“off”

position.

3. Turn the white 

“down”

limit switch (Fig. 2) one-quarter turn clockwise. Test by raising picture surface

approximately two feet, then lower again. Repeat until desired picture surface position is attained.

TENSIONED ADVANTAGE

®

DELUXE  ELECTROL

®

INSTRUCTIONS

220 / 240V WIRING DIAGRAM

WITH ONBOARD LVC

120V WIRING DIAGRAM

WITH ONBOARD LVC

BLACK

WHITE

WHITE
RED (UP)
GRAY
BLACK (DOWN)
GREEN

DOOR SWITCH

SCREEN MOTOR

BLACK

WHITE

BLACK AND YELLOW

LOW-VOLTAGE
WALL SWITCH

BLACK

WHITE

RED

OPTIONAL RF OR IR
REMOTE CONNECTOR

LVC BOARD

WHITE (COMMON)

BLACK (DOWN)

RED (UP)

INPUT

GROUND
BLACK (HOT)
WHITE (COMMON)

120VAC 60HZ
INPUT

DOOR MOTOR

BLACK (CLOSE)

WHITE
RED (OPEN)

GREEN

DOWN

STOP

UP

BROWN

BLACK

BLUE

BLUE
BLACK (UP)
GRAY
BROWN (DOWN)
GREEN

DOOR SWITCH

SCREEN MOTOR

BROWN

BROWN AND
YELLOW

LOW-VOLTAGE
WALL SWITCH

AUX EYE

LVC BOARD

INPUT

GROUND

BLACK

BROWN (HOT)

BLUE
BLACK
BROWN (DOWN)
BLACK (UP)

220/240VAC 50/60HZ
INPUT

DOOR MOTOR

BROWN (CLOSE)
BLUE
BLACK(OPEN)

GREEN

DOWN

STOP

UP

RED

NOTE: Electrical connections on left end of
case.

NOTE: Electrical connections on left end of
case.

BLACK

WHITE

RED

EYE AUX

OPTIONAL RF OR IR
REMOTE CONNECTOR

!

Summary of Contents for Tensioned Advantage Deluxe Electrol Series

Page 1: ... Post Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 Toll Free Fax 877 325 4832 www da lite com e mail info da lite com POWER PRESENTATION PRODUCTS The In Instruction Book for TENSIONED ADVANTAGE DELUXE ELECTROL ...

Page 2: ...remove outer wrapping from case 2 Make sure to recheck measurements of screen location before installation IMPORTANT SAFETY INSTRUCTIONS When using your video equipment basic safety precautions should always be followed including the following 1 Read and understand all instructions before using 2 Position the cord so that it will not be tripped over pulled or contact hot surfaces 3 If an extension...

Page 3: ...ating the screen several times Be prepared to stop the screen The fabric door rear door will not close until the wall switch is placed in the up position and when the screen motor stops at its limit switch in the up direction NOTE Excessive continuous operation may cause the motor to overheat If this happens the motor will shut off until it cools to a normal operating temperature 8 Run the screen ...

Page 4: ...d picture surface position is attained TENSIONED ADVANTAGE DELUXE ELECTROL INSTRUCTIONS 220 240V WIRING DIAGRAM WITH ONBOARD LVC 120V WIRING DIAGRAM WITH ONBOARD LVC BLACK WHITE WHITE RED UP GRAY BLACK DOWN GREEN DOOR SWITCH SCREEN MOTOR BLACK WHITE BLACK AND YELLOW LOW VOLTAGE WALL SWITCH BLACK WHITE RED OPTIONAL RF OR IR REMOTE CONNECTOR LVC BOARD WHITE COMMON BLACK DOWN RED UP INPUT GROUND BLAC...

Page 5: ...D OPEN GREEN SCREEN MOTOR DOOR MOTOR BLACK BROWN BLUE BROWN YELLOW BROWN BROWN DOWN BLACK UP BLUE GRAY GREEN BLUE BLACK TO JUNCTION BOX MOUNTED IN SCREEN CASE IN WHICH INTERNAL WIRING TERMI NATES IN BLUE BROWN AND BLACK LEADS OPERATING SWITCH SWITCH BOX AND PLATE FURNISHED WITH SCREEN SPDT WITH CENTER OFF NOTE A SINGLE SWITCH CANNOT BE USED TO OPERATE MORE THAN ONE SCREEN CONTACT THE FACTORY FOR F...

Page 6: ...ND ELECTRICAL JUNCTION BOX 7 1 4 7 5 8 9 1 4 SUGGESTED 3 8 THREADED ROD NOT INCLUDED ATTACHED TO MOUNTING BRACKET FINISHED CEILING SELF TRIMMING FLANGE 7 1 4 8 3 4 SEE DETAIL A SUGGESTED 3 8 THREADED ROD NOT INCLUDED 4 59 7 21 8 75 DETAIL A 8 74 HANGER BRACKET FLAT BRACKET MOUNTING METHOD FORMED BRACKET MOUNTING METHOD ...

Page 7: ... to open by gravity b No power SOLUTION a Verify 115 125V or 220 240V If insufficient voltage rewire incoming electric line b Replace facility fuse c Reset facility circuit breaker d Check above Tighten all loose wire connections Recheck wiring See installation instructions Down Position Check for power across black and white leads e Let motor cool down for 15 minutes Try again f Check for continu...

Page 8: ...r from screen motor a Down limit switch out of adjustment a Buzzing noise b Gear noise a Defective brake a Pin end slipped out of nylon bearing a Screen not installed properly b Fabric is damaged a Screen up limit out of adjustment a Loose wire SOLUTION a Replace switch b Replace screen motor a See installation instructions a Adjust door limit switch too far down b Replace motor assembly a Replace...

Reviews: