background image

3

Installation

Screen Adjustment

NOTE: 

Unit is not to be installed in air handling space.

1.  Level unit lengthwise with a carpenter's level and plum 

level.

 

CAUTION! Do not completely seal in unit. Access 

room must be allowed for motor repair or fabric 
replacement.

 

ATTENTION! Ne fixez pas complètement l'unité. Un 

espace doit être laissé pour pouvoir réparer le 
moteur ou remplacer la toile.

2.  Remove shipping brace by removing 3 hex head screws 

(Fig. 2).

 

CAUTION! Do not cut wrapping paper or tape with 

knife or any sharp tool. Remove by hand.

 

ATTENTION! Ne coupez pas le papier d'emballage ou 

le ruban adhésif avec un couteau ou un outil 
tranchant. Retirez à la main.

3.  Remove wrapping paper and tape strips (Fig. 2).

4.  Install electrical hook up that applies to your unit. Make 

sure to review your Electrical Installation Checklists and 
wiring diagrams (included) for either 120 volt switch, 

220/240 volt switch, or DRC low voltage control. Unit 

should be installed by a qualified electrician.

 

NOTE: 

Must be installed in accordance with the 

requirements of the Local Building Codes, the Canadian 
Electrical Code (CEC), CAN/CSA C22.1 and the National 
Electric Code (NEC), NFPA 70.

5.  Test installation by carefully running surface up and 

down several times. Be prepared to stop screen.

6.  Check for satisfactory condition by running screen a 

few times.

 

NOTE: 

The picture surface, when rolled down, should 

have a full wrap around the roller. Do not allow any part 
of the roller to become exposed.

Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted at Da-Lite. 
Should it be necessary to adjust for more or less drop of picture (viewing area), proceed in the following manner:

More Screen Drop

1.  Place operating switch in 

“down”

 position.

2.  When the screen stops, turn the

 “down”

 limit knob one-

quarter turn clockwise.

3.  Test by raising picture surface approximately two feet, then 

lower again. Repeat until desired drop is attained.

 

CAUTION! When screen is in bottom position, do not 
adjust for more than 3" of additional drop. Roller should 

not be exposed. 

 

ATTENTION! Lorsque la surface de projection est sur la 

position "Bas", ne déroulez pas la toile plus de 7,6 cm (3 
po).  N'exposer aucune partie du rouleau.

Less Screen Drop

1.  Raise picture surface approximately two feet above desired 

level.

2.  Place operating switch in 

“off”

 position.

3.  Turn the 

“down”

 limit knob one-quarter turn 

counterclockwise.

4.  Test by raising and lowering picture surface.

5.  Repeat steps 3 and 4 until desired drop is attained. 

 

NOTE:

 Limit “down” switch knob controls stopping point of 

picture surface in bottom position.  
Limit “up” switch knob controls stopping point of picture surface 
inside case.

Summary of Contents for Senior Electrol

Page 1: ...INSTRUCTION BOOK FOR Senior Electrol ...

Page 2: ...th ceiling hanger adapters are standard equipment For wall type use wall hanger only For ceiling type installation use the wall type hanger and ceiling adapters as shown in Fig 3 on page 4 Recessed Above Ceiling Other methods of installation will no doubt suggest themselves especially in new buildings where it would be an easy matter to provide a recess for the screen to conceal it when not in use...

Page 3: ...to stop screen 6 Check for satisfactory condition by running screen a few times NOTE The picture surface when rolled down should have a full wrap around the roller Do not allow any part of the roller to become exposed Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted at Da Lite Should it be necessary to adjust for more or ...

Page 4: ...pletely Into Case 1 Place operating switch in up position 2 Turn the up limit knob one quarter turn counterclockwise 3 Test by lowering picture surface approximately two feet with operating switch then raise picture Repeat operation if desired position is not reached Raise Lower Raise Lower Down Up Side View End View Bottom View Outlet Box Suggested Slot Width Picture Surface Wall Or Ceiling Type ...

Page 5: ...acitor Red Up White White Common Up Up Adj Down Adj White White Black With Yellow Down Off Internal Wiring External Wiring To Be Completed By Installer Red Green Ground Motor 120V 60 Cycles 1 10HP Intermittent Duty With Auto Reset Thermal Protector Junction Box Mounted In Screen Case In Which Internal Wiring Terminates In White Black and Red Leads In Multiple Control Installations This Switch Is R...

Page 6: ...rned out motor winding Disconnect motor leads and check for continuity between black and white wires for down position Check for continuity between red and white wires for up position Replace gear motor if either combination shows an open circuit Defective limit switch Disconnect down limit switch from circuit Check for continuity Switches are normally closed and open on contact Motor hums Tempora...

Page 7: ... on motor end of roller Remove shipping bracket Gear noise Gear may need lubrication Apply grease Fabric rubbing Normal condition NOTE Screens with ironing boards have fabric that drags across the board Incorrect stopping point in upward position Lost roller wrap Lift bottom edge up and over roller Limit switch out of adjustment See installation instructions Incorrect stopping point in downward di...

Page 8: ...MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES AS TO FITNESS FOR USE AND MERCHANTABILITY Any implied warranties of fitness for use or merchantability that may be mandated by statute or rule of law are limited to the one 1 year warranty period This warranty gives you specific legal rights and you may also have othe...