Summary of Contents for PRO IMAGER

Page 1: ... 3100 North Detroit Street Post Office Box 137 Warsaw Indiana 46581 0137 Phone 574 267 8101 800 622 3737 Fax 574 267 7804 www da lite com e mail info da lite com POWER PRESENTATION PRODUCTS The In Instruction Book for PRO IMAGER ...

Page 2: ...th a current rat ing at least equal to that of the appliance should be used Cords rated for less amperage than the appliance may over heat 4 To reduce the risk of electric shock do not disassemble this appliance Contact an authorized service dealer when repair work is required Incorrect reassembly can cause electric shock when the appliance is used subsequently 5 The use of an accessory attachment...

Page 3: ...h the pull straps to the bottom slat bar by sliding the looped end of the pull straps over the ends of the slat bar See figure 2 for pull strap attachment The bottom roller is spring loaded and has an internal lock to keep it from retracting during shipping To disen gage the lock pull on the slat bar to unroll the mask but DO NOT let go of the slat bar To lock the roller let the mask retract slowl...

Page 4: ...imension A Perm Wall 3 7 8 Imager 3 7 8 Da Snap 4 3 8 Securely fasten the hanger bracket to the wall It is recommended that you use 10 x 1 3 4 wood screws not supplied and fasten into the wall stud Use a level to make sure the bracket is level To provide easy access to the limit control switches see adjustment proce dures you will need at least 7 clearance above the top of the Pro Imager 3 Hang th...

Page 5: ...SWITCH IS REPLACED BY THE LOW VOLTAGE CONTROL OPER ATED FROM PUSH BUTTON STATIONS THIS SWITCH CANNOT BE USED WITH LVC Note A single switch cannot be used to operate more than one screen Contact the factory for further information SIDE VIEW OF SWITCH AND BOX 120V WIRING DIAGRAM 4 OFF 240 VOLT WIRING DIAGRAM FOR STANDARD WALL SWITCH Da Lite offers two styles of 240 volt wall switches for standard op...

Page 6: ...OUNTER CLOCKWISE to INCREASE the up travel Turn the control a quarter turn at a time and then run the Pro Imager to check the stop position Repeat the above steps until the desired po sition is reached NOTE The bottom of the slat bar should be no more than 1 8 above the edge of the frame while in the up position See figure 2 DOWN LIMIT CONTROL The down limit controls the stop position when the mas...

Page 7: ...or fabric a Defective brake a Pin end slipped out of nylon bearing a Screen not installed properly b Fabric is damaged a Limit switches out of adjustment SOLUTION a Replace facility fuse b Reset circuit breaker c Check above Tighten all loose wire connections Recheck wiring See installation instructions Down Position Check for power across black and white leads d Let motor cool down for 15 minutes...

Page 8: ...Printed in U S A 82391 Rev 7 09 7 ...