4
240V WIRING DIAGRAM
120V WIRING DIAGRAM
MOTOR 2
120VAC-24VDC
TRANSFORMER
MOMENTARY
DRY CONTACT INPUTS
6-BUTTON
WALL SWITCH
T6
1
T6
T4
MOTOR 1
BUS
INTERFACE UNIT
MOTOR 2
RECEPTACLE FOR
MAIN POWER CONNECTION AND
24VDC TRANSFORMER PLUG IN
120VAC 60 HZ
EXTERNAL WIRING
T6 = 6 CONDUCTOR TELEPHONE WIRE
T4 = 4 CONDUCTOR TELEPHONE WIRE
1
= SINGLE CONDUCTOR 18 AWG MAX.
DRY CONTACT REQUIREMENTS:
1. CONTACT CLOSURE MUST BE MAINTAINED FOR AT LEAST
1 SECOND AND NOT MORE THAN 3 SECONDS.
2. A STOP COMMAND IS SENT BY SIMULTANEOUSLY
SENDING AN UP AND DOWN CONTACT CLOSURE.
NOTE: ALL 4 OR 6
CONDUCTOR TELEPHONE
WIRES MUST HAVE THE
CONNECTORS ORIENTED
THE SAME ON BOTH
ENDS. DO NOT REVERSE
THE CONNECTORS AS IS
COMMONLY DONE WITH
TELEPHONE EQUIPMENT.
SEE SUPPLIED WIRE FOR
CORRECT ORIENTATION.
Up
Down
Common
MOTOR 2
120VAC-24VDC
TRANSFORMER
MOMENTARY
DRY CONTACT INPUTS
6-BUTTON
WALL SWITCH
T6
2 TO 1
T6 ADAPTOR
1
T6
T4
MOTOR 1
BUS
INTERFACE UNIT
MOTOR 2
RECEPTACLE FOR
MAIN POWER CONNECTION AND
24VDC TRANSFORMER PLUG IN
240VAC 60 HZ
EXTERNAL WIRING
T6 = 6 CONDUCTOR TELEPHONE WIRE
T4 = 4 CONDUCTOR TELEPHONE WIRE
1
= SINGLE CONDUCTOR 18 AWG MAX.
DRY CONTACT REQUIREMENTS:
1. CONTACT CLOSURE MUST BE MAINTAINED FOR AT LEAST
1 SECOND AND NOT MORE THAN 3 SECONDS.
2. A STOP COMMAND IS SENT BY SIMULTANEOUSLY
SENDING AN UP AND DOWN CONTACT CLOSURE.
NOTE: ALL 4 OR 6
CONDUCTOR TELEPHONE
WIRES MUST HAVE THE
CONNECTORS ORIENTED
THE SAME ON BOTH
ENDS. DO NOT REVERSE
THE CONNECTORS AS IS
COMMONLY DONE WITH
TELEPHONE EQUIPMENT.
SEE SUPPLIED WIRE FOR
CORRECT ORIENTATION.
Up
Down
Common
2 TO 1
T6 ADAPTOR
BLACK
WHITE
GROUND
BLACK
WHITE
GROUND
BROWN
BLUE
GROUND
BROWN
BLUE
GROUND
BLACK
WHITE
GROUND
BROWN
BLUE
GROUND