ACQ132CPCI Hardware Installation Guide
3
Standards Compatibility
Product conforms to PICMG2.0 rev 3.0.
The PCI interface supports Universal [3.3 or 5V] signaling.
The card is capable of performing the CPCI System Slot function.
4
Connectors
It is common practice for customers to manufacture their own cables and termination units,
to fit in with their own sensor requirements. The following sections explains each connector
configuration.
D–TACQ Solutions supply a standard range of cable and termination accessories, and can
also produce custom solutions.
4.1 Front Panel External Clock and Trigger Connectors
Currently fitted with LEMO type EPL.00.250.NTN. Various connector can be used LEMO.
Please refer to LEMO catalogue or website (
www.lemo.com
). A readily available type is
FFA.00.250.CTAC29Z for use with RG174, RG179 and RG188 co-axial cable
Signal Requirements: Signal is opto-coupled. Recommend 5V, centre positive, current in
the ON state will be ~5mA. Clock and Trigger are both edge triggered, but for interlock
reasons it is recommended that the Trigger signal be active for a duration longer than one
Clock.
4.2 Front Panel Ethernet
Standard RJ45 connector, for connection to 10/100/1000 Base T Ethernet.
D–TACQ Solutions Ltd 2009
Doc 1401-4101-000 Rev
1.1 December 2009
Page 4 of 8