④
AC110/220 Converting Switch
Choose suitable kind of Power Sources with this switch.
⑤
P/T POWER SELECT
Can choose suitable kind of Pan/Tilt-activating power. AC110V, AC220V and AC24V are
available.
⑥
TTL/485(422) SELECT
Insert the socket to the pin on your demand. If your socket covers the pin beside which
'RS422/485' is written, you choose 485/422 way
⑦
DATA INPUT
This is an Outlet Box to which Data Lines would be connected when you use RS-422 or
RS-485.
⑧
LPC (LENS POWER CHANGE)
If Zoom Lens operates its zooming In/Out work oppositely, turn the socket over.
⑨
DIP Switch
Sets each receiver (camera)'s address with this switch. (You must turn off the switches
of 9 and 10 if you use 'DCK-255' controller together. If you turn on the switches of 9 and
10, you can use this receiver for DVR Use.)
⑩
TTL Data Input
It is data communication terminals for compatibility with old models. These terminals will
be activated if the socket in COMM SEL box covers the pin named 'TTL'.
⑪
End Resistance Switch (ER)
Notice: Only in the last receiver among the all connected, this switch is to be 'ON'