background image

 

 

 

 

Summary of Contents for xStack DGS-3120-24PC

Page 1: ......

Page 2: ...ference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures CE Mark Warning Dies...

Page 3: ...Switch for Rack Mounting 12 Mounting the Switch in a Standard 19 Rack 13 Power On AC Power 13 Power Failure AC Power 13 Connecting DC Power to the DGS 3120 24SC DC 14 Installing SFP Ports 15 Connecting to a Redundant Power Supply 16 Installing the RPS into a Rack mount Chassis 17 DPS 700 17 DPS 800 18 DPS 900 19 Chapter 3 Connecting the Switch 21 Switch to End Node 21 Switch to Switch 22 Connectin...

Page 4: ...v Appendix A Technical Specifications 32 General 32 Physical and Environmental 33 Performance 33 LED Indicators 34 Port Functions 36 Appendix B Cables and Connectors 38 Ethernet Cable 38 Console Cable 39 Redundant Power Supply RPS Cable 40 Appendix C Module Specs and Cable Lengths 43 ...

Page 5: ...e means that optionally you can type copy followed by the name of the file Do not type the brackets Bold font Indicates a button a toolbar icon menu or menu item For example Open the File menu and choose Cancel Used for emphasis May also indicate system messages or prompts appearing on screen For example You have mail Bold font is also used to represent filenames program names and commands For exa...

Page 6: ... the product only with approved equipment Allow the product to cool before removing covers or touching internal components Operate the product only from the type of external power source indicated on the electrical ratings label If unsure of the type of power source required consult your service provider or local power company To help avoid damaging the system be sure the voltage selection switch ...

Page 7: ...installed could cause the rack to tip over potentially resulting in bodily injury under certain circumstances Therefore always install the stabilizers before installing components in the rack After installing system components in a rack never pull more than one component out of the rack on its slide assemblies at one time The weight of more than one extended component could cause the rack to tip o...

Page 8: ... from your body before touching any of the electronic components such as the microprocessor This can be done by periodically touching an unpainted metal surface on the chassis The following steps can also be taken prevent damage from electrostatic discharge ESD 1 When unpacking a static sensitive component from its shipping carton do not remove the component from the antistatic packing material un...

Page 9: ...10 100 1000 Ports 4 combo 10 100 1000BASE T SFP ports PoE L3 Managed Switch DGS 3120 24SC 16 SFP ports 8 combo 10 100 1000BASE T SFP ports L3 Managed Switch DGS 3120 24SC DC 16 SFP ports 8 combo 10 100 1000BASE T SFP ports L3 Managed Switch with DC power This cost effective Gigabit Switch provides an affordable solution for administrators to upgrade their networks to high speed Gigabit connections...

Page 10: ...List ACL ISM VLAN DHCP local relay Single IP Management Access Authentication Control utilizing TACACS XTACACS TACACS and RADIUS protocols Compound Authentication Power saving mode Simple Network Time Protocol SNTP System Log Maximum packet forwarding rate 65 48 Mpps High performance switching engine performs forwarding and filtering at full wire speed up to 136Gps Full and half duplex for all por...

Page 11: ...cast DM SM SSM Sparse Dense MIB support for o RFC 1213 MIB II o RFC 4188 Bridge MIB o RFC 1907 SNMPv2 MIB o RFC 2819 RMON MIB o RFC 2021 RMONv2 MIB o RFC 2571 SNMP MIB RFC 2572 SNMP MIB RFC 2573 SNMP MIB o RFC 2574 SNMPv3 MIB o RFC 2575 VACM for SNMP MIB o RFC 2576 SNMPv1 v2 v3 MIB o RFC 2665 Ether like MIB o RFC 4363 P Bridge MIB and Q Bridge MIB o RFC 2863 IF MIB o RFC 2618 RADIUS Authentication...

Page 12: ...ts 10 100 1000Mbps and 100 1000Mbps Two dedicated high speed stacking ports DGS 3120 48TC Fourty four Copper ports 10 100 1000Mbps Four Combo Copper SFP ports 10 100 1000Mbps and 100 1000Mbps Two dedicated high speed stacking ports DGS 3120 48PC Fourty eight Copper PoE ports 10 100 1000Mbps Four Combo Copper SFP ports 10 100 1000Mbps and 100 1000Mbps Two dedicated high speed stacking ports All the...

Page 13: ...e below describes LED indicators in more detail The DGS 3120 24PC and DGS 3120 48PC switches are equipt with an additional PoE light to indication whether the ports are running in Power over Ethernet mode Figure 1 1 Front panel view of the DGS 3120 24TC Figure 1 2 Front panel view of the DGS 3120 24SC Figure 1 3 Front panel view of the DGS 3120 24SC DC Figure 1 4 Front panel view of the DGS 3120 2...

Page 14: ... Fan SD Stack ID and Link Act indicators for all ports including the Gigabit Ethernet ports The DGS 3120 24PC and DGS 3120 48PC switches are equipt with an additional PoE light to indication whether the ports are running in Power over Ethernet mode Figure 1 7 LED indicators for the DGS 3120 24TC Figure 1 8 LED indicators for the DGS 3120 24SC Figure 1 9 LED indicators for the DGS 3120 24SC DC ...

Page 15: ...e indicator will light steady green when a user is logged in through the console port RPS This LED will light green if the Redundant Powers Supply is in use If the indicator is off the RPS is not in use When the switch detects that the RPS is connected the light will be blinking This LED in not available on the DGS 3120 24SC DC switch Master For standalone Switches this will light green For stacke...

Page 16: ...es the stacking position of the switch An H indicates the device was assigned as the stacking Master h means the device was selected to be the Backup Master A G is displayed when the Safeguard Engine feature enters the exhausted mode Link Act LEDs The Switch has LED indicators for Link and Activity The LED will light steady green when there is a secure connection or link to a 1000Mbps Ethernet dev...

Page 17: ...s a standard three pronged connector that supports the power cord Plug in the female connector of the provided power cord into this socket and the male side of the cord into a power outlet The Switch automatically adjusts the power setting to any supply voltage in the range from 100 to 240 VAC at 50 to 60 Hz An optional external Redundant Power Supply DPS 200 for DGS 3120 24TC SC DPS 500 DPS 500DC...

Page 18: ... space at the rear and sides of the Switch for proper ventilation Be reminded that without proper heat dissipation and air circulation system components might overheat which could lead to system failure or even severely damage components Figure 1 19 Identical side panels of the DGS 3120 24TC DGS 3120 24SC and DGS 3120 24SC DC Figure 1 20 Identical side panels of the DGS 3120 24PC Figure 1 21 Ident...

Page 19: ...delines Please follow these guidelines for setting up the Switch Install the Switch on a sturdy level surface that can support at least 13 9 lb 6 3 kg of weight Do not place heavy objects on the Switch The power outlet should be within 1 82 meters 6 feet of the Switch Visually inspect the power cord and see that it is fully secured to the AC power port Make sure that there is proper heat dissipati...

Page 20: ... installation on a desktop or shelf Attaching Brackets to a Switch for Rack Mounting The Switch can be mounted in a standard 19 rack using the provided mounting brackets Use the following diagrams as a guide Figure 2 2 Fasten mounting brackets on the Switch Fasten the mounting brackets to the Switch using the screws provided With the brackets attached securely the Switch can be mounted in a standa...

Page 21: ...em Power Failure AC Power For AC power supply units as a precaution in the event of a power failure unplug the Switch When power has resumed plug the Switch back in CAUTION Installing systems in a rack without the front and side stabilizers installed could cause the rack to tip over potentially resulting in bodily injury under certain circumstances Therefore always install the stabilizers before i...

Page 22: ...d positive contacts on the wiring assembly a The negative pole connects to the 48V contact b The positive pole connects to the 48V Return contact c If available an earth ground may be connected to the center contact post 3 Tighten the contact screws to secure the connection NOTE Use a minimum 18 gauge AWG wire All power connection wiring should conform to the rules and regulations in the National ...

Page 23: ...ing SFP ports support full duplex transmissions auto negotiation and can be uplinked with various other switches across a gigabit network The SFP ports support data rates up to 1Gbit s See the figure below for installing the SFP ports in the Switch Figure 2 5 Inserting fiber optic transceivers into the Switch For a full list of supported transceivers compatible with this switch series refer to Por...

Page 24: ...dundant power supply to the main AC power source A green LED on the front of the DPS 200 or DPS 500 will glow to indicate a successful connection 3 Re connect the Switch to the AC power source The LED indicator will show that a redundant power supply is now in operation 4 No change in switch configuration is necessary for this installation NOTE See the RPS Quick Installation Guide for more informa...

Page 25: ...sing a 22 pin DC power cable A standard three pronged AC power cable connects the redundant power supply to the main power source Figure 2 7 Front view of the DPS 700 1 Insert one end of the 22 pin DC power cable into the receptacle on the Switch and the other end into the Redundant Power Supply unit 2 Using a standard AC power cable connect the redundant power supply to the main AC power source A...

Page 26: ... 3120 24PC DPS 800 The DPS 800 is a standard size rack mount 1 standard unit in height designed to hold up to two DPS 200 or DPS 500 redundant power supplies Figure 2 9 Installing the DPS 200 or DPS 500 in the DPS 800 CAUTION Do not connect the DPS 700 to the DGS 3120 24PC 48PC by using the 14 pin DC power cable It may cause damage when using the wrong DC power cable ONLY use the 22 pin DC power c...

Page 27: ...dard 19 rack Use the following diagram to guide you Figure 2 10 Installing the DPS 800 in an Equipment Rack DPS 900 The DPS 900 is a standard size rack mount 5 standard units in height designed to hold up to eight DPS 200 or DPS 500 redundant power supplies Figure 2 11 Inserting the DPS 200 or DPS 500 into the DPS 900 ...

Page 28: ...ck without the front and side stabilizers installed could cause the rack to tip over potentially resulting in bodily injury under certain circumstances Therefore always install the stabilizers before installing components in the rack After installing components in a rack do not pull more than one component out of the rack on its slide assemblies at one time The weight of more than one extended com...

Page 29: ... Ethernet Network Interface Card NIC and routers An end node connects to the Switch via a twisted pair UTP STP cable Connect the end node to any of the 1000BASE T ports of the Switch The Link Act LEDs for each Ethernet port will light green or amber when the link is valid A blinking LED indicates packet activity on that port DGS 3120 24TC S1 Power S2 Console Fan RPS SD Master 100M 1000M Link Act 1...

Page 30: ...tch via a twisted pair Category 3 4 or 5 UTP STP cable Connect a 100BASE TX switch port to the Switch via a twisted pair Category 5 UTP STP cable Connect 1000BASE T switch port to the Switch via a twisted pair Category 5e UTP STP cable Connect switch supporting a fiber optic uplink to the Switch s SFP ports via fiber optic cabling See cabling guidelines in Appendix B for more information Figure 3 ...

Page 31: ...mode The fiber optic ports can operate at both 100Mbps and 1000Mbps in full duplex mode Connections to the Gigabit Ethernet ports are made using a fiber optic cable or Category 5e copper cable depending on the type of port A valid connection is indicated when the Link LED is lit Figure 3 3 Connecting the Switch to a server DGS 3120 24TC S1 Power S2 Console Fan RPS SD Master 100M 1000M Link Act 10 ...

Page 32: ...ment The user can also connect a computer or terminal to the serial console port to access the Switch The command line interface provides complete access to all Switch management features Command Line Interface through the Serial Port or remote Telnet Connecting the Console Port The front panel of the Switch provides a port that enables a connection to a computer monitoring and configuring the Swi...

Page 33: ...lator program If problems occur in making this connection on a PC make sure the emulation is set to VT 100 The emulation settings can be configured by clicking on the File menu in the HyperTerminal window by clicking on Properties in the drop down menu and then clicking the Settings tab This is where you will find the Emulation options If you still do not see anything try rebooting the Switch by d...

Page 34: ... At least one Admin level user account must be created for the Switch Password Protection The Switch does not have a default user name and password One of the first tasks when settings up the Switch is to create user accounts Logging in using a predefined administrator level user name will give the user privileged access to the Switch s management software After the initial login define new passwo...

Page 35: ...ormat of the MIB specifications and the protocol used to access this information over the network The Switch supports SNMP versions 1 2c and 3 The administrator may specify which version of SNMP to use to monitor and control the Switch The three versions of SNMP vary in the level of security provided between the management station and the network device In SNMP v1 and v2 user authentication is acc...

Page 36: ...ages for Authentication Failure Topology Change and Broadcast Multicast Storm MIBs The Switch in the Management Information Base MIB stores management and counter information The Switch uses the standard MIB II Management Information Base module Consequently values for MIB objects can be retrieved from any SNMP based network management software In addition to the standard MIB II the Switch also su...

Page 37: ...ater The browser acts as a universal access tool and can communicate directly with the Switch using the HTTP protocol Logging onto the Web Manager To begin managing the Switch simply run the browser installed on your computer and point it to the IP address you have defined for the device The URL in the address bar should read something like http 123 123 123 123 where the numbers 123 represent the ...

Page 38: ...e table Figure 5 2 Main Web Manager window Area Number Function Area 1 Select the menu or window to display Open folders and click the hyperlinked menu buttons and subfolders contained within them to display menus Click the D Link logo to go to the D Link website Area 2 Presents a graphical near real time image of the front panel of the Switch This area displays the Switch s ports console and mana...

Page 39: ...n the user will be able to configure features regarding the Layer 2 functionality of the Switch L3 Features In this section the user will be able to configure features regarding the Layer 3 functionality of the Switch QoS In this section the user will be able to configure features regarding the Quality of Service functionality of the Switch ACL In this section the user will be able to configure fe...

Page 40: ...00BASE TX UTP Cat 3 4 5 for 10BASE T EIA TIA 568 100 ohm screened twisted pair STP 100m Number of Ports DGS 3120 24TC Twenty four Copper ports 10 100 1000Mbps Four Combo Copper SFP ports 10 100 1000Mbps and 100 1000Mbps Two dedicated high speed stacking ports DGS 3120 24SC Sixteen SFP ports 100 1000Mbps Eight Combo Copper SFP ports 10 100 1000Mbps and 100 1000Mbps Two dedicated high speed stacking...

Page 41: ...120 48PC with 370W PoE load 539 Watts Max DGS 3120 48PC with 740W PoE load 1020 Watts Max Operating Temperature 0 50 C Storage Temperature 40 70 C Humidity Operation 10 90 RH non condensing Storage 5 90 RH non condensing Dimensions DGS 3120 24TC 440mm W x 210mm D x 44mm H DGS 3120 24SC 440mm W x 210mm D x 44mm H DGS 3120 24SC DC 440mm W x 210mm D x 44mm H DGS 3120 24PC 440mm W x 310mm D x 44mm H D...

Page 42: ...master Supports inter stacking trunking and mirroring Cannot stack EI and SI devices together Virtual Stacking Clustering Supports D Link Single IP Management v1 6 Manages up to 32 devices in a virtual stack with a single IP address LED Indicators Location LED Indicative Color Status Description Per Device Power Green Solid Light Power On Light off Power Off Console Green Solid Light Console on Li...

Page 43: ...0 100Mbps Ethernet device at any of the ports Blinking When there is reception or transmission of data occurring at 10 100Mbps Off Light off No link PoE Mode Green Solid Light Power feeding Orange Solid Light Error Condition Off Light Off No Power feeding LED Per SFP Port Link Act Green Solid Light When there is a secure connection or link to 1000Mbps Ethernet device at any of the ports Blinking W...

Page 44: ...ngle mode 80km DEM 210 100BASE FX Single mode 15km DEM 211 100BASE FX Multi mode 2km DGS 712 1000BASE T 1G Copper 100m WDM transceivers supported DEM 330T 1000BASE BX TX 1550 RX 1310nm Single mode 10km DEM 330R 1000BASE BX TX 1310 RX 1550nm Single mode 10km DEM 331T 1000BASE BX TX 1550 RX 1310nm Single mode 40km DEM 331R 1000BASE BX TX 1310 RX 1550nm Single mode 40km DEM 220T 100BASE BX D TX 1550 ...

Page 45: ... 0W 2 Optional 7 0W 3 Optional 15 4W 4 Reserved 31W Class Usage Max power received by PD 0 Default 13 0W 1 Optional 3 84W 2 Optional 6 49W 3 Optional 13 0W 4 Reserved 25 5W Follow the PSE pin out standard of Alternative A sending out power over pins 1 2 3 6 and 8 of CAT3 6A UTP cables for 802 3af devices or CAT5e 6A UTP cables for 802 3at devices The DGS 3120 24PC and DGS 3120 48PC works with all ...

Page 46: ...roducts for matching cable pin assignment The following diagrams and tables show the standard RJ 45 receptacle connector and their pin assignments Figure B 1 The standard RJ 45 port and connector RJ 45 Pin Assignments Contact MDI X Port MDI II Port 1 RD receive TD transmit 2 RD receive TD transmit 3 TD transmit RD receive 4 1000BASE T 1000BASE T 5 1000BASE T 1000BASE T 6 TD transmit RD receive 7 1...

Page 47: ... necessary The following diagrams and tables show the standard Console to DJ 45 receptacle connector and their pin assignments Figure B 2 Console to RJ 45 Cable Console RJ 45 Pin Assignments Pin Console DB9 RS232 RJ 45 1 Not Used Not Used 2 RXD Not Used 3 TXD TXD 4 Not Used GND 5 GND shared GND 6 Not Used RXD 7 Not Used Not Used 8 Not Used Not Used ...

Page 48: ...g cable pin assignment The following diagrams and tables show the standard RPS receptacle connector and their pin assignments 14 pin DC power cable Figure B 3 Redundant Power Supply RPS 14 pin DC Power Cable RPS 14 pin DC Power Cable Pin Assignments Pin Device DPS 200 1 GND GND 2 NC NC 3 12V 12V 4 12V 12V 5 12V 12V 6 12V 12V 7 GND GND 8 GND GND 9 NC Power Good 10 NC Power Present 11 Power Good NC ...

Page 49: ... 3 GND GND 4 GND GND 5 GND GND 6 12V 12V 7 12V 12V 8 RS RS 9 NC GND 10 NC Power Good 11 GND NC 12 Power Good NC 13 5V 5V 14 12V 12V RPS 14 pin DC Power Cable Pin Assignments Pin Device DPS 500DC 1 NC NC 2 GND GND 3 GND GND 4 GND GND 5 GND GND 6 12V 12V 7 12V 12V 8 12V 12V 9 NC Power Present 10 NC Power Good 11 Power Present NC 12 Power Good NC 13 NC NC 14 12V 12V ...

Page 50: ...ower Cable Pin Assignments Pin Device DPS 700 1 54Vrtn 54Vrtn 2 54V 54V 3 12V 12V 4 12V 12V 5 12V 12V 6 12V 12V 7 NC GND GND 8 12Ven 12Ven 9 LS 54V LS 54V 10 54V 54V 11 54Vrtn 54Vrtn 12 GND NC GND 13 GND GND 14 RPS Present Status_2 15 Status_1 RPS PG 16 Status_2 RPS Present 17 RPS PG Status_1 18 GND GND 19 12VRTNsen 12VRTNsen 20 LS 12V LS 12V 21 54Vsen 54Vsen 22 54VRTNsen 54VRTNsen ...

Page 51: ...Single mode 10km DEM 311GT 1000ase SX Multi mode 500m DEM 312GT2 1000Base SX Multi mode 2km DEM 314GT 1000BASE LH Single mode 50km DEM 315GT 1000BASE ZX Single mode 80km DEM 210 100BASE FX Single mode 15km DEM 211 100BASE FX Multi mode 2km DEM 220T 100BASE BX Single mode Up to 20km DEM 220R 100BASE BX Single mode Up to 20km DEM 330T TX 1550 RX 1310nm Single mode Up to 10km DEM 330R TX 1310 RX 1550...

Page 52: ...ation pertaining to the product and in that case the product is being sold As Is without any warranty whatsoever including without limitation the Warranty as described herein notwithstanding anything stated herein to the contrary Submitting A Claim The customer shall return the product to the original purchase point based on its return policy In case the return policy period has expired and the pr...

Page 53: ...ms Inc Other trademarks or registered trademarks are the property of their respective owners Copyright Statement No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc as stipulated by the United ...

Page 54: ...Registration Register your D Link product online at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights ...

Page 55: ...e warranty period on this product U S and Canadian customers can contact D Link technical support through our website or by phone Tech Support for customers within the United States D Link Technical Support over the Telephone USA 877 DLINK 55 877 354 6555 D Link Technical Support over the Internet http support dlink com Tech Support for customers within Canada D Link Technical Support over the Tel...

Page 56: ...00pm Sat 10 00am 02 00pm 0 05ppm peak 0 045ppm off peak Times Internet http dlink com Technische Unterstützung Deutschland Web http dlink com Telefon 49 0 1805 2787 0 14 pro Minute Zeiten Mo Fr 08 30 17 30 Uhr Österreich Web http dlink com Telefon 43 0 820 480084 0 116 pro Minute Zeiten Mo Fr 08 30 17 30 Uhr Schweiz Web http dlink com Telefon 41 0 848 331100 0 08 CHF pro Minute Zeiten Mo Fr 08 30 ...

Page 57: ...15per minuut Tech Support for customers within Belgium http dlink com 028801640 0 175per minuut spitsuren 0 0875per minuut daluren Technische ondereuning voor klanten in Luxemburg http dlink com 32 70 66 06 40 Asistencia Técnica Asistencia Técnica Telefónica de D Link 34 902 30 45 45 0 067 min De Lunes a Viernes de 9 00 a 19 00 http dlink com Supporto tecnico Supporto Tecnico dal lunedì al venerdì...

Page 58: ... 17 00 Volání je zpoplatněno dle příslušných tarifů Vašeho operátora Technikai Támogatás Tel 06 1 461 3001 Fax 06 1 461 3004 Land Line 14 99 HUG min Mobile 49 99 HUF min email support dlink hu URL http dlink com Teknisk Support D Link Teknisk Support over Internett http dlink com D Link Teknisk telefonsupport 815 69 755 Hverdager 08 00 17 00 Teknisk Support D Link teknisk support over telefonen Tl...

Page 59: ...pport Center http dlink com Καλύμνου 12 112 51 Αθήνα Τηλ 213 0020353 Δευτέρα Παρασκευή 09 00 19 00 Fax 210 8653172 Assistência Técnica Assistência Técnica da D Link na Internet http dlink com e mail soporte dlink es Teknisk Support D Link Teknisk Support via Internet http dlink com D Link Teknisk Support via telefon 0770 33 00 35 Vardagar 08 00 17 00 ...

Page 60: ...ink com Tehnična podpora Zahvaljujemo se vam ker ste izbrali D Link proizvod Za vse nadaljnje informacije podporo ter navodila za uporabo prosimo obiščite D Link ovo spletno stran www dlink eu http dlink com Suport tehnic Vă mulţumim pentru alegerea produselor D Link Pentru mai multe informaţii suport şi manuale ale produselor vă rugăm să vizitaţi site ul D Link www dlink eu http dlink com ...

Page 61: ...day 9 30AM to 6 30PM Thursdays 9 30AM to 2 00 PM E mail Support sa dlink me com D Link Middle East Dubai U A E Plot No S31102 Jebel Ali Free Zone South P O Box 18224 Dubai U A E Tel 971 4 8809022 Fax 971 4 8809066 8809069 Technical Support 971 4 8809033 General Inquiries info me dlink me com Tech Support support me dlink me com Egypt 1 Makram Ebeid Street City Lights Building Nasrcity Cairo Egypt ...

Page 62: ...one 212 663 72 73 24 Email support na dlink me com Lebanon RMA center Dbayeh Lebanon PO Box 901589 Tel 961 4 54 49 71 Ext 14 Fax 961 4 54 49 71 Ext 12 Email taoun dlink me com Bahrain Technical Support 973 1 3332904 Kuwait Technical Support 965 22453939 965 22453949 Türkiye Merkez İrtibat Ofisi Ayazağa Maslak yolu Erdebil Cevahir İş Merkezi No 5 A Ayazağa Maslak İstanbul Tel 90 212 2895659 Ücretsi...

Page 63: ...0 г Киев ул Межигорская 87 А офис 18 Тел 38 044 545 64 40 E mail kiev dlink ru Беларусь 220114 г Минск проспект Независимости 169 БЦ XXI Век Тел 375 17 218 13 65 E mail minsk dlink ru Казахстан 050008 г Алматы ул Курмангазы 143 уг Муканова Tел факс 7 727 378 55 90 E mail almaty dlink ru Армения 0038 г Ереван ул Абеляна 6 1 4 этаж Тел Факс 374 10 398 667 E mail erevan dlink ru Грузия Тел Факс 995 5...

Page 64: ...s siguientes teléfonos de D Link PAIS NUMERO Argentina 0800 12235465 Chile 800 260200 Colombia 01800 510070 Costa Rica 0800 0521478 Ecuador 1800 035465 El Salvador 800 6335 Guatemala 1800 8350255 México 01800 0626270 Panamá 011 008000525465 Perú 0800 00968 Venezuela 0800 1005767 Soporte Técnico de D Link a través de Internet Horario de atención Soporte Técnico en www dlinkla com e mail soporte dli...

Page 65: ...Suporte Técnico Caso tenha dúvidas na instalação do produto entre em contato com o Suporte Técnico D Link Acesse o site www dlink com br suporte ...

Page 66: ...區技術支援工程師聯絡 D Link 免付費技術諮詢專線 0800 002 615 手機付費電話 02 6600 0123 8715 服務時間 週一至週五 早上9 00到晚上9 00 不含周六 日及國定假日 網 站 http www dlink com tw 電子郵件 dssqa_service dlink com tw 如果您是台灣地區以外的用戶 請參考D Link網站全球各地 分公司的聯絡資訊以取得相關支援服務 產品保固期限 台灣區維修據點查詢 請參考以下網頁說明 http www dlink com tw 產品維修 使用者可直接送至全省聯強直營維修站或請洽您的原購買經銷商 ...

Page 67: ...okumentasi pengguna dapat diperoleh pada situs web D Link Dukungan Teknis untuk pelanggan Dukungan Teknis D Link melalui telepon Tel 62 21 5731610 Dukungan Teknis D Link melalui Internet Email support dlink co id Website http support dlink co id ...

Page 68: ...Technical Support この度は弊社製品をお買い上げいただき 誠にありがとうご ざいます 下記弊社 Web サイトからユーザ登録及び新製品登録を 行っていただき ダウンロードサービスにて サポート情報 ファームウェア ユーザマニュアルを ダウンロードすることができます ディーリンクジャパン Web サイト URL http www dlink jp com ...

Page 69: ...技术支持 办公地址 北京市东城区北三环东路 36 号 环球贸易中心 B 座 26F 02 05 室 邮编 100013 技术支持中心电话 400 629 6688 技术支持中心传真 028 87300889 各地维修中心地址请登陆官方网站查询 网址 http www dlink com cn 400电话工作时间 工作日9 00 19 00 节假日9 00 18 00 ...

Page 70: ... site 1 employee 2 9 10 49 50 99 100 499 500 999 1000 or more 3 What network protocol s does your organization use XNS IPX TCP IP DECnet Others_____________________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Cisco Network Banyan Vines DECnet Pathwork Windows NT Windows 98 Windows 2000 ME Windows...

Page 71: ......

Reviews: