background image

1  Product Introduction

  

D-Link Smart Managed Switch User Manual

 

 

5

5

 

 

 

Front Panel 

 

Figure 1.7 – DGS-1100-08P Front Panel 

 

Power LED:

 The Power LED lights up when the Switch is connected to a power source. 

Reset:

  Press the Reset button for 1  to 5  seconds to reboot the Switch. Press the Reset button for 6  to10 

seconds to reset the Switch back to the default settings.  The  LED  will  light up solid amber for 2 seconds. 
When pressing the Reset button for longer than 10 seconds, the device will enter loader mode and the LED 
will light up solid green for 2 seconds. If the device cannot reboot, it will automatically enter loader mode. 
Alternatively, you can press Reset to power up the device and enter loader mode.

 

Link/Act/Speed LED (Ports 1-8):

  

Flashing:

 Indicates a network link through the corresponding port.  

Blinking: 

Indicates that the Switch is either sending or receiving data to the port.  

Green:

 Indicates that the port is running at 1000M. 

Amber:

 Indicates that the port is running at 10/100M. 

Light off:

 No link. 

PoE MAX. LED:  

Light up: 

Indicates  the power output to PDs is over 57W. No additional PDs can be powered  for 

safety consideration. 

Blinking: 

Indicates if the user unplugged certain PDs and made the PoE power budget left over 7W, 

the PoE MAX LED will blink 5 seconds. 

Light off: 

Indicates the power budget is using less than 57W. 

PoE LED (Ports 1-8):

 

Green: 

Indicates  the PoE powered device (PD) is connected and the port supplies power 

successfully. 

Red:

 The PoE port has failed, possibly due to: 

1. PoE total power budget shortage. 

2. Over current: Exceeds the power current of powered device's classification. 

3. Short circuit: Short circuit has been performed on a powered device. 

Light off:

 Indicates no Powered Device (PD) connected. 

PoE Mode LED (Port 1-8): 

 

Solid Green:

 PD device insert and power feeding. 

 

Solid Amber:

 PD device insert but failure occurs. 

 

Light off:

 No PD device insert. 

 

Rear Panel 

 

Figure 1.8 – DGS-1100-08P Rear Panel 

 

Power:

 Input for a 54V/1.574A AC adapter. 

Kensington Lock: 

This is used to attach a physical Kensington security lock. 

GND:

 This is used to connect the Switch to ground. 

 

Summary of Contents for EasySmart DGS-1100-05

Page 1: ...D G S 1 1 0 0 0 5 0 8 0 8 P 0 5 P D Ma n u a l S MA R TMA N A G E DS WI T C H V e r 2 1 0...

Page 2: ...0 Management Options 10 Using the Web based Management Interface 10 Connecting to the Switch 10 Accessing the Web based Management Interface 10 Web based Management 11 D Link Network Assistant DNA 11...

Page 3: ...etric VLAN 27 L2 Features VLAN Surveillance VLAN 27 L2 Features VLAN Voice VLAN 29 L2 Features Spanning Tree STP Global Settings 30 L2 Features Spanning Tree STP Port Settings 31 L2 Features Loopback...

Page 4: ...e term Switch first letter capitalized refers to the Smart Managed Switch and switch first letter lower case refers to other Ethernet switches Some technologies refer to terms switch bridge and switch...

Page 5: ...ority queues enabling users to run bandwidth sensitive applications such as streaming multimedia by prioritizing that traffic in network The Surveillance VLAN will place the video traffic from pre def...

Page 6: ...the Switch is connected to a power source If the Power LED is Blinking PoE Pass Through is Off Link Act Speed LED Ports 1 5 Flashing Indicates a network link through the corresponding port Blinking In...

Page 7: ...00 1000 Mbps ports to connect Ethernet devices to the switch Rear Panel Figure 1 6 DGS 1100 08 Rear Panel Power Input for a 5V 1A AC adapter Reset Press the Reset button for 1 to 5 seconds to reboot t...

Page 8: ...Indicates that the port is running at 10 100M Light off No link PoE MAX LED Light up Indicates the power output to PDs is over 57W No additional PDs can be powered for safety consideration Blinking I...

Page 9: ...ertain PDs and made the PoE power budget left over 7W the PoE MAX LED will blink 5 seconds Light off When the power budget is using less the 57W LED Per 10 100 1000 Mbps Port Link Act Speed Green Ambe...

Page 10: ...1 Product Introduction D Link Smart Managed Switch User Manual 7 7 Light off No link...

Page 11: ...y objects on the switch Desktop or Shelf Installation The DGS 1100 series switches come with a strip of four adhesive rubber pads that can be placed on the bottom of the device to prevent the device f...

Page 12: ...ware Installation D Link Smart Managed Switch User Manual 9 9 Step 2 Hook the mounting keyholes on the back of the Switch onto the screws to secure the device to the wall Figure 2 2 Wall mount install...

Page 13: ...ructions for the Web interface and the D Link Network Assistant DNA Using the Web based Management Interface After successfully installing the Switch you can configure and monitor the Switch through t...

Page 14: ...tant DNA is a program that is used to discover switches which are in the same Layer 2 network segment as your PC You can download the DNA App from the Chrome web store and install it in a Chrome web b...

Page 15: ...basic settings Clicking on a section or subsection in the function tree will display all the settings of that section in the main configuration screen The main configuration screen will show the curr...

Page 16: ...es a safe way to reboot the system Click Yes or No to decide to save the settings does this really reset to factory default settings or does it just discard the most recent unsaved changes Click Reboo...

Page 17: ...onfiguration settings from this file Figure 4 9 Tool Menu Configure Backup and Restore Backup current settings to file Specify to back up the current settings of the Swtich with or without the passwor...

Page 18: ...ettings System Information The System Information allows the user to configure the basic system information of the Switch By entering the system information the device can more easily be recognized fr...

Page 19: ...scribed below Item Description IP Settings There are two ways for the Switch to obtain an IP address Static and DHCP Dynamic Host Configuration Protocol When using static mode the IP Address Mask Gate...

Page 20: ...escription Specify a description for the chosen ports Capability Advertised When the Speed is set to Auto these capabilities are advertised during auto negotiation Table 4 3 Click Apply to make the co...

Page 21: ...Status Total PoE Power Budget Displays the total PoE power budget of this switch Power Used Displays the current used power of the switch Power Left Displays the spare power of the switch The percenta...

Page 22: ...on of a port or ports State Select enable or disable to configure PoE function for designated port s Default is Enabled Priority Configure the power supply priority as Low Normal or High on designated...

Page 23: ...nagement Password Access Control The fields that can be configured for Password Access Control are described below Item Description Old Password Enter the old password of the Switch New Password Enter...

Page 24: ...o the management station Coldstart Check this feature to have client devices send an SNMP notification to the management station when performing a cold start Warmstart Check this feature to have clien...

Page 25: ...pecify the community string for the management host Table 4 9 Click Apply to make the configurations take effect Management D Link Discovery Protocol For devices that support the D Link Discovery Prot...

Page 26: ...FDB page allows user to view and configure the static multicast forwarding settings on the Switch Figure 4 25 L2 Features FDB Static FDB Multicast Static FDB The fields that can be configured for Mult...

Page 27: ...iption Port Select a single port or all ports The information for the port s will be displayed in the information table Table 4 14 Click Find to locate a specific entry based on the information entere...

Page 28: ...VID Enter the VID to be created VLAN Name Enter the VLAN name for the VID to be created Port Assign ports as Untag Tag or Not Member Click All to select all ports Table 4 15 Click Apply to create a ne...

Page 29: ...LAN group click Add VLAN and the following will be displayed Figure 4 33 L2 Features VLAN Port Based VLAN Enabled Enter the VLAN Name and select the Member port to be created Click Apply to make the c...

Page 30: ...Asymmetric VLAN The fields that can be configured for Asymmetric VLAN are described below Item Description Asymmetric VLAN State Specify to enable or disable the Asymmetric VLAN of the Switch The def...

Page 31: ...Specify the priority level The levels of priority are High Medium and Low The default priority is High User defined MAC Settings Component Type Surveillance VLAN will automatically detect D Link surve...

Page 32: ...Settings Voice VLAN Specify to enable or disable the Voice VLAN function VLAN ID Specify the VLAN ID to act as a Voice VLAN Priority Specify the priority level The levels of priority are High Medium a...

Page 33: ...n if a BPDU packet is not received Therefore each connection between bridges is sensitive to the status of the link Ultimately this difference results in faster detection of failed links and therefore...

Page 34: ...TP Group Figure 4 39 L2 Features Spanning Tree STP Port Settings The fields that can be configured are described below Item Description From Port To Port Select the range of ports to be included in th...

Page 35: ...to enable or disable loopback detection function The default is Disabled Time Interval 1 32767 Set a Loop detection Interval between 1 and 32767 seconds The default is 10 seconds Recover Time 0 or 60...

Page 36: ...1 Link Aggregation group and DGS 1100 08 supports up to 2 Link Aggregation groups NOTE Each combined port must be connected to devices within the same VLAN group L2 Features L2 Multicast Control IGMP...

Page 37: ...IGMP Snooping group Table 4 26 Click Add to create a new IGMP Snooping group Click Delete to remove the corresponding IGMP Snooping group Click Delete All to remove all IGMP Snooping groups Click Ref...

Page 38: ...a Strict scheduling will set the highest queue to be emptied first while the other queues will follow the weighted round robin scheduling scheme WRR Use the weighted round robin WRR algorithm to handl...

Page 39: ...a group of ports on a single Switch This method of segmenting the flow of traffic is similar to using VLANs to limit traffic but is more restrictive Figure 4 46 Security Traffic Segmentation The field...

Page 40: ...locked to prevent users from modifying the MAC address forwarding table Locking ports also prevents additional MAC addresses from being learned Figure 4 48 Security Port Security The fields that can b...

Page 41: ...e Ethernet cable Open in Cable means the wires of RJ45 cable may be broken or the other end of the cable is simply disconnected Test Failed means and error occurred during the cable test Please select...

Page 42: ...is received on the source port s and forwards it to the Target Port Click all to include all ports into port mirroring Tx Duplicates the data transmitted from the source port and forwards it to the T...

Page 43: ...ded twisted pair UTP cabling a flexible foundation for the next generation of network technology products will be created This will outfit your network with a powerful 1000 Mbps capable backbone serve...

Page 44: ...Duplex operations IEEE 802 3x Flow control support for Full Duplex mode Back Pressure for Half Duplex mode Head of line blocking prevention Support manual auto MDI MDIX configuration Support auto neg...

Page 45: ...Link Smart Managed Switch User Manual 42 Operation Temperature 0 40 C Storage Temperature 40 70 C Operation Humidity 0 90 RH Storage Humidity 0 95 RH EMI Certifications CE FCC ITE RCM VCCI BSMI CCC S...

Page 46: ...ice may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Innovation Science and Economic Development Can...

Page 47: ...statique de votre corps en touchant un objet en m tal reli la terre par exemple avant de toucher le produit N essayez pas d intervenir sur le produit et ne le d montez jamais Pour certains produits co...

Page 48: ...as fuentes de calor Desenchufe siempre el producto de la alimentaci n de red antes de limpiarlo y utilice solo un pa o seco sin pelusa VEILIGHEIDSINFORMATIE De volgende algemene veiligheidsinformatie...

Page 49: ...DE Dieses Symbol auf dem Produkt oder der Verpackung weist darauf hin dass dieses Produkt gem bestehender rtlicher Gesetze und Vorschriften nicht ber den normalen Hausm ll entsorgt werden sollte sond...

Page 50: ...ado al fin de su vida til algunos de ellos aceptan recogerlos de forma gratuita Al reciclar el producto y su embalaje de esta forma contribuye a preservar el medio ambiente y a proteger la salud de lo...

Page 51: ...producten uit te schakelen of uit de stekker te halen wanneer u ze niet gebruikt Door dit te doen bespaart u energie en beperkt u de CO2 emissies Breng een bezoek aan www dlinkgreen com voor meer info...

Page 52: ...www dlinkgreen com MAGYAR HU Ez a szimb lum a term ken vagy a csomagol son azt jelenti hogy a helyi t rv nyeknek s szab lyoknak megfelel en ez a term k nem semmis thet meg a h ztart si hullad kkal egy...

Page 53: ...ke m bortskaffes som husholdningsaffald mens skal sendes til genbrug Indlever produktet til et indsamlingssted som angivet af de lokale myndigheder n r det er n et til slutningen af dets levetid I nog...

Page 54: ...ygger D Link sina produkter f r att de ska vara s milj v nliga som m jligt genom att anv nda tervinningsbara material med l g gifthalt i b de produkter och f rpackningar D Link rekommenderar att du al...

Page 55: ......

Reviews: