background image

DXS-3610 Series 100 Gigabit Ethernet Managed Switch 
Hardware Installation Guide 

Summary of Contents for DXS-3610 Series

Page 1: ...DXS 3610 Series 100 Gigabit Ethernet Managed Switch Hardware Installation Guide ...

Page 2: ...e received including interference that may cause undesired operation D Link Corporate 17595 Mt Hermann Street Fountain Valley CA 92708 800 326 1688 CE Mark Warning This equipment is compliant with Class A of CISPR 32 In a residential environment this equipment may cause radio interference Avertissement Concernant la Marque CE Cet équipement est conforme à la classe A de la norme CISPR 32 Dans un e...

Page 3: ...talling PSU Modules into the PSU Module Slots 12 Installing AC PSU Modules 12 Installing DC PSU Modules 13 Installing Fan Modules into the Fan Module Slots 16 Smart Fans 17 4 Switch Connections 18 Stacking the Switch 18 Switch to Switch 20 Switch to Server 20 Switch to End Node 21 5 Switch Management 22 Management Options 22 Command Line Interface CLI 22 Connecting to the Console Port 22 Logging i...

Page 4: ...e Installation Guide iv Safety Sécurité 34 Safety Instructions 34 Safety Cautions 34 Consignes de sécurité 35 Précautions de sécurité 35 General Precautions for Rack Mountable Products 37 Protecting Against Electrostatic Discharge 38 Warranty Technical Support 39 ...

Page 5: ...s the Switch throughout this manual Typographical Conventions Convention Description Boldface Font This convention is used to place emphasis on keywords It also indicates a button toolbar icon menu menu item system message or a prompt appearing on the screen For example click the Apply button Initial capital letter This convention is used to indicate a window name or keyboard key For example press...

Page 6: ...ized schedule and by allowing ports to automatically enter a hibernated state Switch Series The following switches are part of the DXS 3610 series DXS 3610 54T L3 stackable 10GbE managed switch with 48 RJ45 10 Gbps and 6 QSFP28 100 Gbps ports DXS 3610 54S L3 stackable 10GbE managed switch with 48 SFP 10 Gbps and 6 QSFP28 100 Gbps ports Package Contents Open the shipping carton of the Switch and ca...

Page 7: ...o USB port provides additional storage space for firmware images and configuration files that can be copied to and from the Switch Only endpoint devices like USB flash drives are supported Reset Button The reset button can be used to reboot the switch or to reset the switch to its factory default settings depending on how long this button is pressed Press and hold for less than 5 seconds This rebo...

Page 8: ...P QSFP28 transceivers Front Panel LED Indicators The LED indicators provide valuable information in a variety of ways like their color blinking times and location Figure 2 3 DXS 3610 54T Front Panel LED Indicators Figure 2 4 DXS 3610 54S Front Panel LED Indicators The front panel LED indicators are described in the following table LED Color Status Description Locator Blue On Solid User logged in O...

Page 9: ... 1 On Solid Active connection at 100 Gbps through the port On Blinking Data transmitted and received through the port Blue LED 4 On Solid Active connection at 40 Gbps through the port On Blinking Data transmitted and received through the port Off Inactive connection no link present or port disabled Stacking Master 100GE QSFP28 ports White LED 1 Amber LED 2 On Solid Active connection at 100 Gbps th...

Page 10: ...r dos à dos ou face à face Figure 2 5 DXS 3610 54T DXS 3610 54S Rear Panel AC PSU Figure 2 6 DXS 3610 54T DXS 3610 54S Rear Panel DC PSU This following table lists the rear panel components on the Switch Port Description Switch GND Use an electrical grounding wire and connect one end of the wire to the switch GND and the other end of the wire to an electrical grounding point most commonly found on...

Page 11: ... are described in the following table LED Color Status Description Power Supply Module Green On Solid Normal power supply module operation On Blinking PSU module is off but standby power is supplied Amber On Solid PSU Fan failed or PSU shutdown due to critical event On Blinking Warning event occurred Power Current Temperature too high or fan is too slow Off Power off or PSU is on but with warning ...

Page 12: ...bout the acceptable operating temperature and humidity ranges refer to the Physical and Environmental section Install the Switch in a site free from strong electromagnetic field generators such as motors vibration dust and direct exposure to sunlight Installing the Switch without a Rack This section is used to guide the user through installing the Switch in an area other than a switch rack Attach ...

Page 13: ...nstalling the Switch in a Standard 19 Rack This section is used to guide the user through installing the Switch into a switch rack The Switch can be mounted in a standard 19 1U rack using the rack mounting kit included in the package contents Fasten the frontal rack mounting brackets to the front sides of the Switch using the screws provided Figure 3 2 Attaching the frontal rack mounting brackets ...

Page 14: ...nto place as illustrated below Figure 3 4 Positioning the rear rack mounting brackets Fasten the mounting brackets in any available open space in the rack using the screws provided Figure 3 5 Installing the Switch in a Rack Make sure that there is adequate space around the Switch to allow for proper airflow ventilation and cooling ...

Page 15: ... These ports are generally used to connect this switch to optical fiber connections and can be used to connect devices to the Switch over great distances The maximum distance that the RJ45 wiring connection can reach is 100 meters Fiber optic connections can span several kilometers NOTE The DXS 3610 54T and DXS 3610 54S is equipped with QSFP28 ports Only the DXS 3610 54S is equipped with SFP ports...

Page 16: ... Link SFP SFP QSFP QSFP28 transceivers that are supported on the Switch refer to the Supported SFP SFP QSFP QSFP28 Transceivers table on page 30 NOTE Only use pluggable optical modules and Direct Attach Cables DAC that meet the following regulatory requirements Class 1 Laser Product UL and or CSA registered component for North America FCC 21 CFR Chapter 1 Sub chapter J in accordance with FDA CDRH ...

Page 17: ...d AC PSU modules This section can be referenced when one or more AC PSU modules need to be replaced CAUTION Make sure that the AC power cord is removed from the Switch and that the Switch is not receiving any power The power fan and other LED indicators must be off ATTENTION Assurez vous que le cordon d alimentation CA est débranché du commutateur et que le commutateur ne reçoit pas de courant L a...

Page 18: ...ally power on and adjust its power settings to adapt to any voltage supplied within the 100 240VAC range at 50 60Hz Installing DC PSU Modules Switches in this series can also be shipped with two pre installed DC PSU modules This section can be referenced when one or more DC PSU modules need to be replaced CAUTION Make sure that the DC power supply source is disconnected from the Switch and that th...

Page 19: ...t until the release clip securely clicks into place Figure 3 10 Installing a DC PSU Module Figure 3 11 Installed DC PSU Module A second DC PSU module can be installed into the second PSU module slot labelled PSU 2 If the primary DC PSU fails the second DC PSU is used to provide DC power to the Switch This takes place immediately and automatically ...

Page 20: ...votre installation par un électricien qualifié et agréé CAUTION When installing a DC powered switch ground the chassis before connecting the switch to the DC power source and following the following instructions Use a minimum of 18 AWG stranded copper wire for grounding The wire should be long enough to reach from the installed switch to the facility ground point Ground additional hardware appropr...

Page 21: ...is shipped with five DXS FAN200 modules pre installed NOTE The fan modules support a specific airflow direction This airflow direction must be the same as the PSU module s installed The default airflow direction is front to back on all the installed PSU modules and fan modules To remove an existing fan module use a flat head screwdriver to unscrew the lag bolt with a slot drive head and gently pul...

Page 22: ...re is so sensitive that it can even adjust the speed of the fan to accurately control the internal temperature The following table lists at what temperature the speed of the fan s will change Switch Fan Module Low Speed Medium Speed High Speed DXS 3610 54T DXS FAN200 Below 30 C At roughly 35 C Above 40 C DXS FAN200 B Below 30 C At roughly 35 C Above 40 C DXS 3610 54S DXS FAN200 Below 30 C At rough...

Page 23: ...series can be physically stacked with optical fiber cables or Direct Attached Cables DACs with QSFP QSFP28 connectors Only the last 6 QSFP28 ports on the Switch can be used for physical stacking The following stacking topologies are supported on the Switch Duplex Chain This topology stacks switches together in a chain link format Using this method data transfer is only possible in one direction If...

Page 24: ...IO2 are logical stacking port pairs A logical stacking port pair must always be connected to the same Switch in the stack Splitting logical stacking port pairs between different Switches in the stack might not guarantee a stable stacking connection The following table lists the stacking configuration with the corresponding SIO port pairs Configuration Logical SIO1 Logical SIO2 Bandwidth 2 port Por...

Page 25: ...te cabling Connect a 1000BASE T switch port to the Switch via a Category 5e UTP STP cable Connect a 10GBASE T switch port to the Switch via a Category 6 6a 7 UTP STP cable Connect a fiber uplink switch port to the Switch s SFP QSFP28 port via a fiber optical cable Figure 4 3 Switch to another Switch Hub Switch to Server The Switch is ideal for connecting to a network backbone server or server farm...

Page 26: ...ccess Points Print Servers VoIP Phones and more Each end node should be fitted with an RJ45 networking port Normally end nodes will connect to this switch by using a standard twisted pair UTP STP network cable When a successful connection is established the corresponding port light will illuminate and blink to indicate that network activity is taking place on that port The diagram below displays a...

Page 27: ...onsole port offers an Out Of Band OOB connection to the CLI and the LAN ports offers an in band connection to the CLI using Telnet or SSH NOTE For more information about the CLI refer to the DXS 3610 Series CLI Reference Guide Connecting to the Console Port The Console port is used to connect to the CLI of the Switch Connect the DB9 connector of the console cable included in the packaging to the S...

Page 28: ...ount use the username command in the Global Configuration Mode Switch configure terminal Switch config username NewUser password 12345 Switch config username NewUser privilege 15 Switch config A user account with the username NewUser password 12345 and privilege level 15 was created NOTE Usernames can be up to 32 characters in length Passwords can be up to 32 plain text characters in length Passwo...

Page 29: ... information about the Web UI refer to the DXS 3610 Series Web UI Reference Guide Connecting to the Web UI To access the Web UI open a standard web browser enter the IP address of the Switch into the address bar of the browser and press the Enter key Figure 5 2 IP address in Internet Explorer NOTE The default IP address of the switch is 10 90 90 90 subnet mask 255 0 0 0 The default username and pa...

Page 30: ... here Click the D Link logo to go to the D Link website AREA 2 In this area a toolbar with access to functions like Save Tools and a Logout option is available The user account and IP address currently accessing the Web UI is displayed on the right in this toolbar AREA 3 In this area the software features available in the Web UI are grouped into folders containing hyperlinks that will open window ...

Page 31: ...SNMP managers can be created to view read only information or receive traps using SNMP version 1 while assigning a higher level of security to another group granting read write privileges using SNMP version 3 Using SNMP version 3 individual users or groups of SNMP managers can be allowed to perform or be restricted from performing specific SNMP management functions The functions that have been all...

Page 32: ...z 330 2 Watts 240 VAC 50 Hz 315 9 Watts Standby 100 VAC 60 Hz 103 7 Watts 240 VAC 50 Hz 120 6 Watts DXS 3610 54S Maximum 100 VAC 60 Hz 320 8 Watts 240 VAC 50 Hz 305 1 Watts Standby 100 VAC 60 Hz 120 6 Watts 240 VAC 50 Hz 114 6 Watts MTBF DXS 3610 54T FB Airflow 96503 Hours with AC power 74204 Hours with DC power BF Airflow 96806 Hours with AC power 50044 Hours with DC power DXS 3610 54S FB Airflow...

Page 33: ...Air 8 KV Performance Specification Feature Description Switching Capacity DXS 3610 54T 2 16 Tbps DXS 3610 54S 2 16 Tbps MAC Address Table Up to 288K entries 1K static MAC addresses Physical Stacking Topology Duplex Ring and Duplex Chain Bandwidth Up to 1 2 Tbps Full duplex Stack Number Up to 12 Switches Configurations 2 port Ports 53 to 54 4 port Ports 51 to 54 6 port Ports 49 to 54 Packet Buffer ...

Page 34: ...tures Standards IEEE 802 3ab 1000BASE T IEEE 802 3an 10GBASE T IEEE 802 3az Energy Efficient Ethernet IEEE 802 3x Full Duplex Flow Control The RJ45 ports support the following features Back pressure for half duplex mode Head of line blocking prevention Manual auto MDI MDIX configuration Auto Negotiation for each port SFP Ports The SFP transceiver ports provides in band access to the CLI and Web UI...

Page 35: ...XT 10GBASE ZR Single mode 80 km 1550 nm SFP Copper Transceivers Product Code Standard Connector Distance TX RX Power Amps DGS 712 1000BASE T SFP to RJ45 100 m 3 3 V 375 mA SFP Copper Transceivers Product Code Standard Connector Distance TX RX Power Amps DEM 410T 10GBASE T SFP to RJ45 30 m 3 3 V 780 mA WDM BiDi SFP Transceivers Product Code Standard Mode Distance TX RX DEM 330T 1000BASE BX D Single...

Page 36: ...sceivers Product Code Standard Mode Distance TX RX DEM Q2801Q SR4 100GBASE SR4 Multi mode 100 m 850 nm DEM Q2801Q LR4 100GBASE LR4 Single mode 10 km L0 1295 56 nm L1 1301 05 nm L2 1304 58 nm L3 1309 14 nm QSFP28 Direct Attached Cables DAC Product Code Standard Cable Dist Wire Ω Amps DEM CB100Q28 100G QSFP28 Twinaxial 1 m 30 AWG 100 Ω 0 5 A Certifications EMC Certifications CE Class A FCC Class A V...

Page 37: ...ing diagrams and tables show the standard RJ45 receptacle connector and their pin assignments Figure B 1 Standard RJ45 port and connector RJ45 Pin Assignment Contact MDI X Port MDI II Port 1 RD receive TD transmit 2 RD receive TD transmit 3 TD transmit RD receive 4 1000BASE T 10GBASE T 1000BASE T 10GBASE T 5 1000BASE T 10GBASE T 1000BASE T 10GBASE T 6 TD transmit RD receive 7 1000BASE T 10GBASE T ...

Page 38: ...witch to access the command line interface The following diagram and table show the standard RJ45 to RS 232cable and pin assignments Figure B 2 Console to RJ45 Cable RJ45 To RS 232 Cable Pin Assignment Table Contact Console DB9 RS232 RJ45 1 Not Used Not Used 2 RXD Not Used 3 TXD TXD 4 Not Used GND 5 GND shared GND 6 Not Used RXD 7 Not Used Not Used 8 Not Used Not Used ...

Page 39: ...wer from the device Keep the system away from radiators and heat sources Also do not block cooling vents Do not spill food or liquids on system components and never operate the product in a wet environment If the system gets wet contact your trained service provider Do not push any objects into the openings of the system Doing so can cause fire or electric shock by shorting out interior components...

Page 40: ...ply is set to match the power available at the Switch s location 115V 60Hz is used mostly in North and South America as well as Far Eastern countries like as South Korea and Taiwan 100V 50Hz is used mostly in Eastern Japan and 100V 60Hz in Western Japan 230V 50Hz is used mostly in Europe the Middle East Africa and the Far East CAUTION Risk of Explosion if Battery is replaced by an Incorrect Type D...

Page 41: ...eurs nominales indiquées sur l appareil Pour éviter tout risque de choc électrique branchez les câbles d alimentation du système et des périphériques à des prises électriques correctement mises à la masse Ces câbles sont équipés de fiches à trois broches pour garantir une mise à la masse appropriée N utilisez pas d adaptateur de prise et n éliminez pas la broche de mise à la masse du câble Si un c...

Page 42: ...before working on the rack Always load the rack from the bottom up and load the heaviest item in the rack first Make sure that the rack is level and stable before extending a component from the rack Use caution when pressing the component rail release latches and sliding a component into or out of a rack the slide rails can pinch your fingers After a component is inserted into the rack carefully e...

Page 43: ...chassis The following steps can also be taken prevent damage from electrostatic discharge ESD When unpacking a static sensitive component from its shipping carton do not remove the component from the antistatic packing material until ready to install the component in the system Just before unwrapping the antistatic packaging be sure to discharge static electricity from your body When transporting ...

Page 44: ...iquidators expressly disclaim their warranty obligation pertaining to the product and in that case the product is being sold As Is without any warranty whatsoever including without limitation the Limited Warranty as described herein notwithstanding anything stated herein to the contrary Submitting A Claim The customer shall return the product to the original purchase point based on its return poli...

Page 45: ...opyright Statement No part of this publication or documentation accompanying this product may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc as stipulated by the United States Copyright Act of 1976 and any amendments thereto Contents are subject to change without...

Page 46: ...Registration Register your D Link product online at http support dlink com register Product registration is entirely voluntary and failure to complete or return this form will not diminish your warranty rights ...

Page 47: ...onfiguration Please refer to the user manual to learn more or visit http www mydlink com for more information Also feel free to contact us U S and Canadian customers can contact D Link Technical Support through our website USA http support dlink com Canada http support dlink ca ...

Page 48: ... ASISTENCIA TÉCNICA SUPPORTO TECNICO TECHNISCHE ONDERSTEUNING POMOC TECHNICZNA TECHNICKÁ PODPORA TECHNIKAI TÁMOGATÁS TEKNISK STØTTE TEKNISK SUPPORT TEKNINEN TUKI TEKNISK SUPPORT ASSISTÊNCIA TÉCNICA ΤΕΧΝΙΚΉ ΥΠΟΣΤΉΡΙΞΗ TEHNIČKA PODRŠKA TEHNIČNA PODPORA SUPORT TEHNIC ТЕХНИЧЕСКА ПОДДРЪЖКА TECHNICKÁ PODPORA ...

Page 49: ...ndonesia www dlink co id Malaysia www dlink com my Philippines www dlink com ph Vietnam www dlink com vn Korea customers Tel 1899 3540 Monday to Friday 9 30am to 6 30pm Web http d link co kr E mail support kr dlink com New Zealandcustomers Tel 0800 900 900 24 7 Technical Support Web http www dlink co nz E mail support dlink co nz South Africa and Sub Sahara Region customers Tel 27 12 661 2025 0860...

Page 50: ...ch Support support eg me dlink com Kingdom of Saudi Arabia Technical Support 966 1121 70009 General Inquiries info sa me dlink com Tech Support support sa me dlink com Pakistan Technical Support 92 21 34548310 34305069 General Inquiries info pk me dlink com Tech Support support pk me dlink com Morocco Phone office 212 700 13 14 15 Email morocco me dlink com Bahrain Technical Support 973 1 3332904 ...

Page 51: ...рез Интернет Техническая поддержка компании D Link работает в круглосуточном режиме ежедневно кроме официальных праздничных дней Звонок бесплатный по всей России Техническая поддержка D Link 8 800 700 5465 Техническая поддержка через Интернет http www dlink ru e mail support dlink ru Изготовитель Д Линк Корпорейшн 114 Тайвань Тайпей Нэйху Дистрикт Шинху 3 Роуд 289 Уполномоченный представитель импо...

Page 52: ...Қазақстан Алматы Құрманғазы к cі 143 үй Тел 7 727 378 55 90 E mail almaty dlink ru Հայաստան Երևան Դավթաշեն 3 րդ թաղամաս 23 5 Հեռ 374 10 39 86 67 Էլ փոստ info dlink am Latvija Rīga Lielirbes iela 27 Tel 371 6 761 87 03 E mail info dlink lv Lietuva Vilnius Žirmūnų 139 303 Tel 370 5 236 36 29 E mail info dlink lt Eesti E mail info dlink ee Türkiye Uphill Towers Residence A 99 Ataşehir ISTANBUL Tel 90...

Page 53: ...inkla com soporte call center Soporte Técnico de D Link a través de Internet Horario de atención Soporte Técnico en www dlinkla com e mail soporte dlinkla com consultas dlinkla com Clientes de Brasil Caso tenha dúvidas na instalação do produto entre em contato com o Suporte Técnico D Link Acesse o site www dlink com br suporte ...

Page 54: ...2 6600 0123 8715 台灣網站 http www dlink com tw 台灣電子郵件 dssqa_service dlink com tw 產品保固期限 台灣技術諮詢時間 維修據點查詢 請參考http www dlink com tw 網頁 說明 香港 澳門D Link技術諮詢專線 香港技術諮詢服務專線 852 8100 8892 香港網站 http www dlink com hk 香港電子郵件 service cn synnex grp com 香港 澳門維修據點查詢請參考http www dlink com hk contact html 網頁說明 如果您是其他地區的用戶 請參考D Link網站www dlink com 查詢全球各地分公司的聯絡 資訊以取得相關支援服務 ...

Page 55: ...a Dukungan Teknis D Link melalui Internet Pertanyaan Umum sales id dlink com Bantuan Teknis support id dlink com Website http www dlink co id 日本のお客様 この度は弊社製品をお買い上げいただき 誠にありがとうございます 製品に同梱されている保証書の購入元にお問い合わせください 中國客戶 技術支持中心電話 400 629 6688 家用産品熱線 4006 828 828 企業産品熱線 技術支持中心郵箱 dlink400 cn dlink com 各地維修中心地址請登錄官方網站查詢 網址 http www dlink com cn 400電話工作時間 工作日9 00 19 00 節假日9 00 18 00 ...

Page 56: ... site 1 employee 2 9 10 49 50 99 100 499 500 999 1000 or more 3 What network protocol s does your organization use XNS IPX TCP IP DECnet Others_____________________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Cisco Network Banyan Vines DECnet Pathwork Windows NT Windows 98 Windows 2000 ME Windows...

Page 57: ......

Reviews: