Connecting The DWL-P200

At this point, your Network Device should have power and data,  and 

function normally.

Connect the provided Cat 5 Ethernet cable from the Terminal Unit “LAN 

OUT” to the RJ-45 LAN port of the Network Device.

Summary of Contents for DWL-P200

Page 1: ...ers are designed to supply operational power to a Network Device These adapters eliminate the need to use an additionalAC DC power supply at the Network Device giving you the ability to mount an Network Device virtually anywhere in a building where power outlets are not available for example in ceilings attics D Link s DWL P200 Adapters take advantage of the unused cable pairs within Ethernet Cat ...

Page 2: ... switch Power In using the supplied 48V power supply connect to a wall power outlet P DATA IN connect a CAT 5 RJ 45 straight through cable from the P Data Out port on the Base Unit LAN OUT connect a CAT 5 RJ 45 straight through cable to an Ethernet enabled device Voltage Selector used to select DC 5V 2 5A or 12V 1A DC Out supplies 5V 2 5 or 12V 1 amps of power Using the included power cable connec...

Page 3: ...er into the DC 48V IN Base Unit and the other end into your electrical outlet The green PWR LED on the Base Unit should light up Do Not mistake the LAN IN port with the P DATA OUT port Incorrectly plugging the wrong Ethernet cable into the wrong Ethernet port may cause serious damage to your network devices D Link will not replace or repair products or reimburse customers for devices that become d...

Page 4: ... DWL P200 Insert one end of the DC Power Cable that is provided into the Terminal Unit and the other end into the DC of the Network Device The Power LED of the Terminal Unit should light up Only use a CAT 5 Ethernet straight through cable Use Voltage Selector to set DC output to 5V 2 5A or 12V 1A as required by the Network Device ...

Page 5: ...ting The DWL P200 At this point your Network Device should have power and data and function normally Connect the provided Cat 5 Ethernet cable from the Terminal Unit LAN OUT to the RJ 45 LAN port of the Network Device ...

Page 6: ...ating Humidity 10 to 80 Warranty 1 Year Specifications Features Provides DC power over existing CAT 5 cabling to Access Points Transforms incoming AC power into low voltage DC power Base and Terminal Power Over Ethernet modules powers any Network Device requiring 5V or 12V DC input Protects Access Points from possible damages due to power surges Output 5VDC 2 5A or 12VDC 1A LAN Computer D Link Wir...

Page 7: ...ubai U A E Plot No S31102 Jebel Ali Free Zone South P O Box 18224 Dubai U A E Tel 971 4 8809022 Fax 971 4 8809066 8809069 Technical Support 971 4 8809033 General Inquiries info me dlink me com Tech Support support me dlink me com Egypt 1 Makram Ebeid Street City Lights Building Nasrcity Cairo Egypt Floor 6 office C2 Tel 2 02 26718375 2 02 26717280 Technical Support 2 02 26738470 General Inquiries ...

Page 8: ...lanca Maroc Phone 212 663 72 73 24 Email support na dlink me com Lebanon RMA center Dbayeh Lebanon PO Box 901589 Tel 961 4 54 49 71 Ext 14 Fax 961 4 54 49 71 Ext 12 Email taoun dlink me com Bahrain Technical Support 973 1 3332904 Kuwait Technical Support 965 22453939 965 22453949 Türkiye Merkez İrtibat Ofisi Ayazağa Maslak yolu Erdebil Cevahir İş Merkezi No 5 A Ayazağa Maslak İstanbul Tel 90 212 2...