Category 5 pin power usages: 4/5 , 7/8
§
Output Voltage 5VDC/1A (Terminal side)
§
Ethernet Connector: RJ-45
§
Ethernet Data Rate: 10/100 Mbps
§
Number of AP’s it can power: 1
§
Ethernet Data Cable: TIA/EIA-568, Category 5 Cable
§
Device Weight (pair): 0.269 lbs
§
Dimensions: 3.15in x 1.73in
Hardware Installation
Hardware Installation
1. Connect the cable from the PC/Hub/Switch to the Base Unit “LAN IN”
2. Connect the Power Adapter to the Base Unit “DC 15V IN.” The green
PWR LED on the Base Unit should light up.
3. Connect the cable from the Base Unit “LAN OUT” to the “LAN IN” of
the Terminal Unit. (max cable length up to 328ft/100m, as defined by
IEEE 802.3)
4. Connect an Ethernet cable from the Terminal Unit “LAN OUT” to the
LAN port of the Wireless Access Point (AP).
5. Connect the “DC 5V OUT” from the Terminal Unit to the DC 5V input
port of the AP using the power cable provided. The green PWR LED of
the Terminal Unit should light up.
6. Operate the Wireless Access Point normally.