Immediately after power-up, all of the LED’s should show steady 
green for several seconds.  Then the LPT1, LPT2, and LPT3 LEDs 
should flash on simultaneously three times.  Irregularity of any of the 
three LEDs during these LED tests may mean there is a problem with 
the LEDs themselves.  Contact your dealer for correction of any LED 
problems before proceeding. 

The actual component tests immediately follow the LED tests.  A 
normal (no fault) result is signaled by a series of three cycles of 
sequential flashing of the three LEDs, followed by a quiescent state 
with all three LEDs dark. 

If the self-test routine traps any component error, then following the 
LED tests the self-test will halt and the LED’s will continuously signal 
the error according to the following table.  In the event of any such 
error signal, contact your dealer for correction of the faulty unit. 

 

LED Name

 

Faulty 

LPT1 

LPT2 

LPT3 

Component 

Off 

off 

on/steady 

LPT3 error 

Off 

off 

flashing 

Parallel-3 Controller error 

Off 

on/steady 

off 

LPT2 error 

Off 

flashing 

off 

Parallel-2 Controller error

 

Off 

flashing 

flashing 

Flash Protected 

on/steady 

off 

off 

LPT1 error 

on/steady 

off 

on/steady 

Timer INT error 

on/steady 

on/steady 

off 

RAM error 

Flashing 

off 

off 

Parallel-1 Controller error 

Flashing 

flashing 

off 

Flash erase/program error  

Flashing 

flashing 

flashing 

Need to reload firmware 

Summary of Contents for DP-313 - Air 802.11b Wireless Print Server

Page 1: ...1 DP 313 Wireless Print Server User s Manual Rev 02 August 2001 ...

Page 2: ... 9 Unpacking and Inspecting the Print Server 9 Installing the Print Server 10 Power On Self Test 12 Testing Your Print Server 14 3 CONTACTING TECHNICAL SUPPORT 16 4 PRODUCT SPECIFICATIONS 17 Printer Connection 17 Wireless Network Connection 17 Network Protocols 18 Management and Diagnostics 18 Environmental and Physical 18 5 PORT PINOUTS 20 Parallel Ports 20 6 LIMITED WARRANTY 22 7 D LINK OFFICES ...

Page 3: ...ng a description of the print server s features as well as the print server installation procedures and troubleshooting self test results For information about software configuration of the Print Server to allow it to be used with your network consult the PS Admin User s Guide included with your Print Server ...

Page 4: ... network printing services in three ways The Print Server picks up the workload of managing print file traffic to its connected printers This provides workload relief to your file servers and allows the file servers full capacity to be used for file access or other direct services to network users On peer to peer networks workstations can print directly to the Print Server without increasing the l...

Page 5: ...P NetBEUI Windows NT 2000 Windows 95 98 Me Windows for Workgroups Microsoft LAN Manager IBM LAN Server AppleTalk MacOS EtherTalk Windows based setup and administration software PS Admin is supplied with the Print Server making configuration and management quick and easy The Print Server also supports configuration and management via the telnet protocol for networks without Windows compatible machi...

Page 6: ...Note The PC s IP address must correspond with the print server s IP address in the same segment for the two devices to communicate Rear Panel Wireless DIP Switch The Print Server s rear panel features a DIP switch allowing two different modes of ad hoc and infrastructure In ad hoc mode there are 2 types of settings 802 11 ad hoc mode and Proprietary ad hoc mode where there is direct communication ...

Page 7: ...ed for three seconds or when the LEDs on LPT1 LPT2 LPT3 begins to light up solid Release the reset button and LPT1 LPT2 LPT3 LEDs will begin to flash indicating the print server is changing to factory reset When factory reset is completed the print server s wireless setting will be set to default on channel 6 and ESS ID is set as default DC Power Connector The DC power input connector is located o...

Page 8: ...at the Print Server has wireless quality connections to the network in either ad hoc or infrastructure mode If only the first Wireless LED indicator lights up it indicates poor wireless quality connection When the first second LED indicator lights up simultaneously it indicates a moderate wireless quality connection If all three LED indicators light up simultaneously it shows a high quality wirele...

Page 9: ...tics Unpacking and Inspecting the Print Server Carefully remove all items from the package In addition to this Hardware User s Guide be certain that you have DP 313 Wireless Print Server Power Adapter User s Manual Print Server Software Quick Installation Guide If any item is missing or if you find any damage or mismatch promptly contact your dealer for assistance ...

Page 10: ...u Before initiating set up procedure for the print server make sure your wireless PCMCIA card on your PC Notebook is set to channel 6 with ESS ID set as default in ad hoc mode u Make sure the DIP switch on the print server is positioned in the ad hoc mode u Press the Reset button on the print server for three seconds until the LPT begins to light up initiating the factory reset u When factory rese...

Page 11: ...cedure for the print server make sure your wireless PCMCIA card on your PC Notebook is set to channel 6 with ESS ID set as default in ad hoc mode u Make sure the DIP switch on the print server is positioned in the ad hoc mode u Press the Reset button on the print server for three seconds until the LPT begins to light up initiating the factory reset u When factory reset is completed the print serve...

Page 12: ...rt to the printer port of the Print Server 6 Switch ON each connected printer 7 Plug the AC power adapter s DC output plug into the DC 5V power socket on the rear panel of the Print Server 8 Plug the power adapter into an electric service outlet This will supply power to the Print Server as it has no external power switch The Power LED on the Print Server s front panel should light steady green an...

Page 13: ...ee LEDs dark If the self test routine traps any component error then following the LED tests the self test will halt and the LED s will continuously signal the error according to the following table In the event of any such error signal contact your dealer for correction of the faulty unit LED Name Faulty LPT1 LPT2 LPT3 Component Off off on steady LPT3 error Off off flashing Parallel 3 Controller ...

Page 14: ...unction for confirmation of printer cable connections and functions That operational test can be completed after you have installed the PS Admin software and have configured your Print Server and its ports See the Testing Your Print Server section of the PS Admin User s Guide ...

Page 15: ...15 DIP Switch Setting ...

Page 16: ... www dlink com Email support dlink com Phone 949 788 0805 option 4 If you are a customer residing outside of the United States please refer to the list of D Link locations that is included in this manual Thank you for purchasing this product We like to receive feedback from our customers concerning our products Please take a moment to visit our web site You can register your purchase on line learn...

Page 17: ... 25 pin parallel ports 3 Parallel Port Bi directional Communication Hewlett Packard PJL Printer Job Language supported Wireless Network Connection Network Standards Wireless LAN standard IEEE 802 11b Network Data Transfer Rate 11Mbps with fallback to 5 5Mbps 2Mbps and 1Mbps Network Mode Either Ad hoc or Infrastructure mode ...

Page 18: ...nostics Standard SNMP MIBs MIB II RFC 1213 Diagnostic LED Indicators Power Link Act Wireless Quality LPT1 LPT2 LPT3 Environmental and Physical Power Supply DC 5V 2 4A Dimensions 223 3mm 131 7mm 35mm Weight approx 460g Operating Temperature 0 to 50 C Storage Temperature 25 to 55 C Humidity 5 to 95 non condensing Emissions FCC Class A CISPR 22 Class A VCCI Class 1 ...

Page 19: ...19 Safety UL UL 1950 CSA CSA950 TUV GS EN60950 ...

Page 20: ...6 pin Centronics connector used on most printers Signal names beginning with n are active low signals 25 pin Centronics Signal Source 1 1 nStrobe Host 2 2 Data 1 Bi directional 3 3 Data 2 Bi directional 4 4 Data 3 Bi directional 5 5 Data 4 Bi directional 6 6 Data 5 Bi directional 7 7 Data 6 Bi directional 8 8 Data 7 Bi directional 9 9 Data 8 Bi directional 10 10 nAck Printer 11 11 Busy Printer 12 ...

Page 21: ...21 25 pin Centronics Signal Source 16 31 nInit Host 17 36 nSelectIn Host 18 25 16 17 19 30 Ground ...

Page 22: ...pplies and fans One 1 Year Power Supplies and Fans One 1 Year Spare parts and spare kits Ninety 90 days D Link s sole obligation shall be to repair or replace the defective Hardware at no charge to the original owner Such repair or replacement will be rendered by D Link at an Authorized D Link Service Office The replacement Hardware need not be new or of an identical make model or part D Link may ...

Page 23: ... The license granted respecting any Software for which a refund is given automatically terminates What You Must Do For Warranty Service Registration Card The Registration Card provided at the back of this manual must be completed and returned to an Authorized D Link Service Office for each D Link product within ninety 90 days after the product is purchased and or licensed The addresses telephone f...

Page 24: ...sclaimer of Other Warranties EXCEPT FOR THE LIMITED WARRANTY SPECIFIED HEREIN THE PRODUCT IS PROVIDED AS IS WITHOUT ANY WARRANTY OF ANY KIND INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NON INFRINGEMENT IF ANY IMPLIED WARRANTY CANNOT BE DISCLAIMED IN ANY TERRITORY WHERE A PRODUCT IS SOLD THE DURATION OF SUCH IMPLIED WARRANTY SHALL BE LIMITED TO ...

Page 25: ... of D Link Corporation D Link Systems Inc All other trademarks belong to their respective proprietors Copyright Statement No part of this publication may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc as stipulated by the United States Copyright Act of 1976 ...

Page 26: ...00 INDIA D LINK INDIA Plot No 5 Kurla Bandra Complex Road Off Cst Road Santacruz E Bombay 400 098 India TEL 91 22 652 6696 FAX 91 22 652 8914 URL www dlink india com E MAIL service dlink india com ITALY D LINK ITALIA Via Nino Bonnet No 6 b 20154 Milano Italy TEL 39 02 2900 0676 FAX 39 02 2900 1723 URL www dlink it E MAIL info dlink it JAPAN D LINK JAPAN 10F 8 8 15 Nishi Gotanda Shinagawa ku Tokyo ...

Page 27: ...following questions help us to support your product 1 Where and how will the product primarily be used oHome oOffice oTravel oCompany Business oHome Business oPersonal Use 2 How many employees work at installation site o1 employee o2 9 o10 49 o50 99 o100 499 o500 999 o1000 or more 3 What network protocol s does your organization use oXNS IPX oTCP IP oDECnet oOthers_____________________________ 4 W...

Page 28: ...28 __________________________________________________________________________________________ ...

Reviews: