13
Immediately after power-up, all of the LED’s should show steady
green for several seconds. Then the LPT1, LPT2, and LPT3 LEDs
should flash on simultaneously three times. Irregularity of any of the
three LEDs during these LED tests may mean there is a problem with
the LEDs themselves. Contact your dealer for correction of any LED
problems before proceeding.
The actual component tests immediately follow the LED tests. A
normal (no fault) result is signaled by a series of three cycles of
sequential flashing of the three LEDs, followed by a quiescent state
with all three LEDs dark.
If the self-test routine traps any component error, then following the
LED tests the self-test will halt and the LED’s will continuously signal
the error according to the following table. In the event of any such
error signal, contact your dealer for correction of the faulty unit.
LED Name
Faulty
LPT1
LPT2
LPT3
Component
Off
off
on/steady
LPT3 error
Off
off
flashing
Parallel-3 Controller error
Off
on/steady
off
LPT2 error
Off
flashing
off
Parallel-2 Controller error
Off
flashing
flashing
Flash Protected
on/steady
off
off
LPT1 error
on/steady
off
on/steady
Timer INT error
on/steady
on/steady
off
RAM error
Flashing
off
off
Parallel-1 Controller error
Flashing
flashing
off
Flash erase/program error
Flashing
flashing
flashing
Need to reload firmware