10
•
Install the Switch in a site free from strong electromagnetic
field generators (such as motors), vibration, dust, and direct
exposure to sunlight.
•
Leave at least 10cm of space to the front and rear of the
Switch for ventilation.
•
Install the Switch on a sturdy, level surface that can support
its weight, or in an EIA standard-size equipment rack. For
information on rack installation, see the next section,
Rack
Mounting.
•
When installing the Switch on a level surface, attach the
rubber pads (feet) to the bottom. The rubber feet cushion the
switch and helps protect the case from scratches.
Figure 1 – Attach the adhesive rubber pads to the bottom
Rack Mounting
The Switch can be mounted in an EIA standard-size, 19-inch rack or
chassis, which can be located in a wiring closet with other equipment.
Attach the mounting brackets to the Switch’s side panels (one on each
side), and secure them with the provided screws.