4 Configuration
DGS-1210 series Metro Ethernet Managed Switch User Manual
1
1
2
2
9
9
Click
Apply
to make the configurations take effect.
Monitoring > sFlow > sFlow Flow Sampler Settings
This sFlow Flow Sampler Settings page allows user to configure the sFlow flow sampler parameters. By
configuring the sampling function for a port, a sample packet received by this port will be encapsulated and
forwarded to the analyzer server at the specified interval.
Figure 4.200 - Monitoring > sFlow > sFlow Flow Sampler Settings
From Port / To Port:
User the drop-down to specify the list of ports to be configured.
Analyzer Server ID (1-4):
The analyzer server ID specifies the ID of a server analyzer where the packet will
be forwarded.
RX Rate (0-65535):
The sampling rate for packet Rx sampling. The configured rate value multiplied by 256 is
the actual rate. For example, if the rate is 20, the actual rate 5120. One packet will be sampled from every
5120 packets. If set to 0, the sampler is disabled. If the rate is not specified, its default value is 0.
TX Rate (0-65535):
The sampling rate for packet Tx sampling. The configured rate value multiplied by 256 is
the actual rate. For example, if the rate is 20, the actual rate 5120. One packet will be sampled from every
5120 packets. If set to 0, the sampler is disabled. If the rate is not specified, its default value is 0.
Max Header Size (18-256):
The maximum number of leading bytes in the packet which has been sampled
that will be encapsulated and forwarded to the server. If not specified, the default value is 128.
Click
Apply
to make the configurations take effect.
Click
Delete All
to remove all entries.
Monitoring > sFlow > sFlow Counter Poller Settings
This sFlow Counter Poller Settings page allows user to configure the sFlow counter poller settings. If the
user wants to change the analyzer server ID, he needs to delete the counter poller and create a new one.
Figure 4.201 - Monitoring > sFlow > sFlow Counter Poller Settings
From Port / To Port:
Use the drop-down menus to specify the list of ports to be configured.
Analyzer Server ID (1-4):
The analyzer server ID specifies the ID of a server analyzer where the packet will
be forwarded.
Interval (20-120):
The maximum number of seconds between successive samples of the counters.
Click
Apply
to make the configurations take effect.