background image

D-Link GoSwitch5G/GoSwitch8G Unmanaged Gigabit Ethernet Switch

 

13 

latency 

 

The delay between the time a device receives a packet and the time the packet is forwarded out of the 

destination port. 

line speed 

– See 

baud rate

main port 

– The port in a resilient link that carries data traffic in normal operating conditions. 

MDI 

 

Medium Dependent Interface. An Ethernet port connection where the transmitter of one device is connected to 

the receiver of another device. 

MDIX 

– Medium Dependent Interface Cross-over. An Ethernet port connection where the internal transmit and 

receive lines are crossed. 

MIB 

– Management Information Base. Stores a device’s management characteristics and parameters. MIBs are used 

by the Simple Network Management Protocol (SNMP) to contain attributes of their managed systems. The Switch 
contains its own internal MIB.  

multicast 

– Single packets copied to a specific subset of network addresses. These addresses are specified in the 

destination-address field of the packet. 

protocol 

– A set of rules for communication between devices on a network. The rules dictate format, timing, 

sequencing, and error control. 

resilient link 

– A pair of ports that can be configured so that one will take over data transmission should the other fail. 

See also 

main port 

and 

standby port

RJ-45 

– Standard 8-wire connectors for IEEE 802.3 10BASE-T networks. 

RMON 

– Remote Monitoring. Subset of SNMP MIB II, which allows monitoring and management capabilities by 

addressing up to ten different groups of information. 

RPS 

 

Redundant Power System. A device that provides a backup source of power when connected to the Switch. 

server farm 

– A cluster of servers in a centralized location serving a large user population. 

SLIP 

– Serial Line Internet Protocol. A protocol that allows IP to run over a serial line connection. 

SNMP 

– Simple Network Management Protocol. A protocol originally designed to be used in managing TCP/IP 

internets. SNMP is presently implemented on a wide range of computers and networking equipment and may be used 
to manage many aspects of network and end station operation. 

Spanning Tree Protocol 

– (STP)

 

A bridge-based system for providing fault tolerance on networks. STP works by 

allowing you to implement parallel paths for network traffic, and to ensure that redundant paths are disabled when the 
main paths are operational and enabled if the main paths fail. 

stack 

– A group of network devices that are integrated to form a single logical device. 

standby port 

– The port in a resilient link that will take over data transmission if the main port in the link fails. 

switch 

– A device that filters, forwards, and floods packets based on the packet’s destination address. The Switch 

learns the addresses associated with each switch port and builds tables based on this information to be used for the 
switching decision. 

TCP/IP 

– A layered set of communications protocols providing Telnet terminal emulation, FTP file transfer, and other 

services for communication among a wide range of computer equipment. 

Telnet 

– A TCP/IP application protocol that provides virtual terminal service, letting a user log in to another computer 

system and access a host as if the user were connected directly to the host. 

TFTP 

– Trivial File Transfer Protocol. Allows you to transfer files (such as software upgrades) from a remote device 

using your switch’s local management capabilities. 

UDP 

– User Datagram Protocol. An Internet standard protocol that allows an application program on one device to 

send a datagram to an application program on another device. 

VLAN 

 

Virtual LAN. A group of location- and topology-independent devices that communicate as if they are on a 

common physical LAN. 

VLT 

 

Virtual LAN Trunk. A Switch-to-Switch link which carries traffic for all the VLANs on each Switch. 

VT100 

 

A type of terminal which uses ASCII characters. VT100 screens have a text-based appearance. 

 
 
 
 
 
 
 
 

Summary of Contents for DGS-1005A

Page 1: ...GoSwitch5G GoSwitch8G 5 8 Port 10 100 1000Mbps Switch Manual RECYCLABLE V2 0 ...

Page 2: ...ng This is a Class B product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Warnung Dies ist ein Produkt der Klasse B Im Wohnbereich kann dieses Produkt Funkstoerungen verursachen In diesem Fall kann vom Benutzer verlangt werden angemessene Massnahmen zu ergreifen Precaución Este es un producto de Clase B En un e...

Page 3: ... TECHNOLOGY 1 SWITCHING TECHNOLOGY 2 SWITCH DESCRIPTION 2 Features 2 FRONT PANEL COMPONENTS 3 LED Indicators 4 REAR PANEL DESCRIPTION 5 INSTALLATION 6 Package Contents 6 BEFORE YOU CONNECT TO THE NETWORK 6 POWER ON 7 Power Failure 7 CONNECTING THE SWITCH 8 SWITCH TO END NODE 8 SWITCH TO HUB OR SWITCH 8 CONNECTING TO NETWORK BACKBONE OR SERVER 9 TECHNICAL SPECIFICATIONS 10 GLOSSARY 12 ...

Page 4: ...witch to an end node hub Switch or backbone server Appendix A Technical Specifications The technical specifications of the GoSwitch5G GoSwitch8G Glossary Lists definitions for terms and acronyms used in this document Intended Readers The GoSwitch5G GoSwitch8G Manual contains information for setup and management and of the GoSwitch5G GoSwitch8G Switch This manual is intended for network managers fa...

Page 5: ...pe of power source required consult your service provider or local power company To help avoid damaging your system be sure the voltage selection switch if provided on the power supply is set to match the power available at your location 115 volts V 60 hertz Hz in most of North and South America and some Far Eastern countries such as South Korea and Taiwan 100 V 50 Hz in eastern Japan and 100 V 60...

Page 6: ...rs are secured to the rack extended to the floor and that the full weight of the rack rests on the floor Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on the rack Always load the rack from the bottom up and load the heaviest item in the rack first Make sure that the rack is level and stable before extending a component from the ra...

Page 7: ...o take the following steps to prevent damage from electrostatic discharge ESD 1 When unpacking a static sensitive component from its shipping carton do not remove the component from the antistatic packing material until you are ready to install the component in your system Just before unwrapping the antistatic packaging be sure to discharge static electricity from your body 2 When transporting a s...

Page 8: ... bottlenecks that frequently develop as computers and their busses get faster and more users use applications that generate more traffic Upgrading key components such as your backbone and servers to Gigabit Ethernet can greatly improve network response times as well as significantly speed up the traffic between your subnetworks Gigabit Ethernet enables fast optical fiber connections to support vid...

Page 9: ...sed to split parts of the network into different collision domains for example making it possible to expand your Fast Ethernet network beyond the 205 meter network diameter limit for 100BASE TX networks Switches supporting both traditional 10Mbps Ethernet and 100Mbps Fast Ethernet are also ideal for bridging between existing 10Mbps networks and new 100Mbps networks Switching LAN technology is a ma...

Page 10: ...RAM for data buffering IEEE 802 3x flow control for full duplex Back pressure flow control for half duplex Jumbo Frame Support at 1000Mbps 9216Bytes Front Panel Components The top case of the Switch consists of LED indicators 5 8 10 100 1000 Mbps Ethernet ports Figure 1 1 Front Panel View of the Switch Comprehensive LED indicators display the status of the Switch and the network ...

Page 11: ... Indicators The LED indicators of the Switch include Power and Link Act as described below For GoSwitch5G Power Indicator This green indicator light is on when the Switch is receiving power otherwise it is off Link Act This LED indicator light is green when the port is connected to a device The green indicator blinks as data is transmitted or received For GoSwitch8G Power Indicator This green indi...

Page 12: ... AC power adapter Check the technical specification section for information about the AC power input voltage Figure 1 3 Rear panel view of the Switch 10 100 1000BASE T Ports Five and eight 5 8 Gigabit Ethernet Auto Negotiating ports 10 100 1000Mbps Comprehensive LED indicators display the conditions of the Switch and status of the network ...

Page 13: ... sturdy level surface that can support at least 3 kg 6 6 lbs of weight Do not place heavy objects on the Switch The power outlet should be within 1 82 meters 6 feet of the Switch Visually inspect the power cord and see that it is fully secured to the AC power port Make sure that there is adequate space for proper heat dissipation from and adequate ventilation around the Switch Leave at least 10 cm...

Page 14: ...ctor of the Switch and the other end into the local power source outlet After the Switch is powered on the LED indicators will momentarily blink This blinking of the LED indicators represents a reset of the system Power Failure As a precaution in the event of a power failure unplug the Switch When power is resumed plug the Switch back in ...

Page 15: ...n be connected to any of the ports of the Switch Figure 3 1 Switch connected to an end node Switch to Hub or Switch These connections can be accomplished in a number of ways using a standard Ethernet cable A 10BASE T hub or switch can be connected to the Switch via a twisted pair Category 3 4 5 or 5e UTP STP cable A 100BASE T hub or switch can be connected to the Switch via a twisted pair Category...

Page 16: ...cted to a port on a hub or switch using either a straight or crossover cable any standard Ethernet cable is fine Connecting To Network Backbone or Server Any of the five Gigabit Ethernet ports are ideal for uplinking to a network backbone or network server Figure 3 3 Connection to a Server ...

Page 17: ...uplex Gigabit Ethernet 2000Mbps Full duplex Topology Star Network Cables Ethernet 2 pair UTP Cat 3 4 5 Unshield Twisted Pair UTP Cable Fast Ethernet 2 pair UTP Cat 5 Unshield Twisted Pair UTP Cable Gigabit Ethernet 4 pair UTP Cat 5 Unshield Twisted Pair UTP Cable Number of Ports Five Eight 10 100 1000BASE T Gigabit Ethernet ports Physical and Environmental DC Inputs AC DC 5V 1A Operating Temperatu...

Page 18: ...itch 11 Performance Transmission Method Store and forward RAM Buffer 128KBytes per device Filtering Address Table 2K GoSwitch5G 8K GoSwitch8G MAC address per device Packet Filtering Forwarding Rate Full wire speed MAC Address Learning Self learning auto aging ...

Page 19: ...sent to all destination devices on the network broadcast storm Multiple simultaneous broadcasts that typically absorb available network bandwidth and can cause network failure console port The port on the Switch accepting a terminal or modem connector It changes the parallel arrangement of data within computers to the serial form used on data transmission links This port is most often used for ded...

Page 20: ...ement Protocol A protocol originally designed to be used in managing TCP IP internets SNMP is presently implemented on a wide range of computers and networking equipment and may be used to manage many aspects of network and end station operation Spanning Tree Protocol STP A bridge based system for providing fault tolerance on networks STP works by allowing you to implement parallel paths for netwo...