D-Link DGE-500SX User Manual Download Page 7

6

Installation

Unpacking

CAUTION:

Under ordinary circumstances, a DGE-500SX card will not be affected by static charge as may be received
through your body during handling of the unit.  However, there are special circumstances where you may
carry an extraordinarily high static charge, and possibly damage the card and/or your computer. It is good
practice to eliminate all static electricity by touching a ground (an unpainted metal area of your computer
chassis, for example) before performing any installations.

Open the shipping carton and carefully remove all items. In addition to this User's Guide, ascertain that you
have:

 

 

One DGE-500SX Giga-Ether Adapter Card.

 

 

One DGE-500SX Software CD-ROM.

Installing the Adapter

1.

 

Shut down the computer, unplug its power cord, and remove the chassis cover.

2.

 

Insert the contact edge of the DGE-500SX card into the connector of any available PCI Bus Master
expansion slot.  Press the card firmly into the connector such that the card’s contacts are fully seated in the
connector.

3.

 

Install the bracket screw which secures the card to the computer chassis.

4.

 

Replace the computer’s chassis cover.

5.

 

Reconnect the computer’s power cord, and switch computer power on.  If the BIOS section of your
computer’s boot program is Plug-and-Play compliant, then at power-up the BIOS will automatically
configure any newly installed DGE-500SX adapter.

NOTE:  Due to a fault in some Plug-n-Play BIOS programs, it happens occasionally that a newly installed adapter is

assigned an Interrupt Number which is already assigned to another device.  In such a case, the conflict of Interrupt
Number will cause faults in the behavior of both devices.  Then it is necessary to run the CMOS Setup utility, and
manually assign a non-conflicting Interrupt Number.

Connecting the Network Cable

Multimode (62.5/125

µ

m or 50/125

µ

m) fiber cabling with an IEEE recommended SC connector is required for the

adapter.  Use either one duplex SC connector, or two simplex SC connectors, and observe the correct
relationship between the receive (Rx) and transmit (Tx) ports on the adapter and switch.  The Tx port on the
switch should connect to the Rx port on the adapter. Likewise, the Rx port on the switch should connect to the
Tx port on the adapter. If there is a need to monitor the adapter’s faceplate LEDs, make sure the rear of the PC
or workstation is accessible and leave sufficient clearance for cabling and service.

Software Installation

Windows NT v4.0

1.

 

Make sure the network adapter has been installed in your computer, boot it up, and start Windows NT 4.0.

2.

 

Open "My Computer" 

 "Control Panel" 

 "Networks".

3.

 

Select "Add adapter" 

 "Have disk".

4.

 

Type the following: 

A:\

   (where 

A:

 is the floppy drive)  OR  

D:\

   (where 

D:

 is the CD drive).

5.

 

Select "D-Link DGE-500SX Giga-Ether Adapter"  (see below).

Summary of Contents for DGE-500SX

Page 1: ...DGE 500SX Giga Ether Adapter User s Guide Rev 01 September 1999 6DGE500SX 01 Printed in Taiwan RECYCLABLE ...

Page 2: ... Software Warranty service for software products may be obtained by contacting a D Link office within the applicable warranty period A list of D Link offices is provided at the back of this manual together with a copy of the Registration Card If a Registration Card for the product in question has not been returned to a D Link office then a proof of purchase such as a copy of the dated purchase inv...

Page 3: ... IN NO EVENT WILL D LINK BE LIABLE FOR ANY DAMAGES INCLUDING LOSS OF DATA LOSS OF PROFITS COST OF COVER OR OTHER INCIDENTAL CONSEQUENTIAL OR INDIRECT DAMAGES ARISING OUT THE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF A D LINK PRODUCT HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY THIS LIMITATION WILL APPLY EVEN IF D LINK HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE IF...

Page 4: ...ng the same packet structure format and support for CSMA CD protocol full duplex and management objects but with a tenfold increase in theoretical throughput over 100Mbps Fast Ethernet and a one hundred fold increase over 10Mbps Ethernet Since it is compatible with all 10Mbps and 100Mbps Ethernet environments Gigabit Ethernet provides a straightforward upgrade without wasting a company s existing ...

Page 5: ...hancement In addition the DGE 550SX uses the following advanced features to maximize the utilization of the PCI bus and reduce overhead on the system CPU Bus Master technology the NIC masters the PCI bus freeing the CPU from PCI bus management duties Direct Memory Access DMA enables the NIC to write directly to the system memory freeing the CPU from many memory management duties Burst transfers fu...

Page 6: ...850nm 62 5 125 fiber optic cable Cable lengths up to 500 meters using 850nm 50 125 fiber optic cable Built in 96K buffers reduce memory transfer overhead and optimize operating bandwidth throughput and network data integrity Level One LXT1001GMAC Gigabit Ethernet MAC controller containing a built in 64 bit 33 MHz PCI interface Four LED indicators Full Duplex Link and Transmit Receive 1000Mbps Driv...

Page 7: ...en at power up the BIOS will automatically configure any newly installed DGE 500SX adapter NOTE Due to a fault in some Plug n Play BIOS programs it happens occasionally that a newly installed adapter is assigned an Interrupt Number which is already assigned to another device In such a case the conflict of Interrupt Number will cause faults in the behavior of both devices Then it is necessary to ru...

Page 8: ...4 0 will then ask you to reboot the PC Select YES 9 Restart the computer NetWare Server 5 0 The following is for the initial installation from the install menu Skip this section if it is not your first time using the install menu 1 Start the NetWare Server by typing in the following commands CD NWSERVER SERVER 2 After booting up type the following command NWCONFIG 3 Select Driver Options Configure...

Page 9: ...cify the directory which includes DLKGE LDI DLKGE LAN For example A NETWARE 32BITLAN where A is the floppy drive OR D NETWARE 32BITLAN where D is the CD ROM drive 7 Select DLKGE LAN Note Don t copy the NLM files to your system if the version of the ones on the installation disk are older than those already on your system 8 Specify SLOT and Node Address if necessary 9 Select Save parameters and loa...

Page 10: ... LAN in the Select a driver windows 5 Specify SLOT and Node Address if necessary 6 Select Save parameters and load driver after configuring the adapter settings The NetWare server will now automatically load bind the driver Next you will need to modify your NetWare 5 0 Server s Autoexec file To do so please follow these steps 1 Start the NetWare Server by typing in the following commands CD NWSERV...

Page 11: ... NEGOTIATE parameter causes the DLKGE to auto negotiate the duplex mode and link speed with the device being connected TXDMATHRESHOLD The TXDMATHERESHOLD determines the I O method used to move transmit packets from host memory to the DLKGE memory The valid range for the TXDMATHRESHOLD is 0 1514 the default value is 800 DISABLERXIP Disables the DLKGE TCP IP Receive Packet checksum support By defaul...

Page 12: ...alified for the application such as 1000BASE SX The DGE 500SX Adapter features four LED indicators FDX Steady green indicates the adapter is operating in Full Duplex mode 1000M The LED indicator lights green when a 1000 Mbps device is connected to the adapter Link Steady green indicates good linkage between the DGE 500SX and its supporting server or switch TX RX Flashing green indicates activity t...

Page 13: ...cation Class B VCCI Class B and C Tick Host interface PCI Bus Bus Master I O base address assigned by Plug and Play system Interrupt Number Assigned by Plug and Play system Physical Dimensions 16 2 x 9 5 cm Environment Storage 5 to 55 C 23 to 131 F Operating 0 to 50 C 32 to 122 F Humidity 5 to 95 non condensing Power Consumption 7 8W ...

Page 14: ...nce fr GERMANY D LINK GERMANY Bachstr 22 D 65830 Kriftel Germany TEL 49 0 6192 97110 FAX 49 0 6192 971111 WEB www dlink de BBS 49 0 6192 9711 98 ISDN INFO 00800 7250 0000 toll free HELP 00800 7250 4000 toll free INDIA D LINK INDIA Plot No 5 Kurla Bandra Complex Rd Off Cst Rd Santacruz E Bombay 400 098 India TEL 91 22 6526578 FAX 91 22 6528476 WEB www dlink india com ITALY D LINK ITALY Via Nino Bon...

Reviews: