![D-Link DES-5024 - Switch User Manual Download Page 39](http://html.mh-extra.com/html/d-link/des-5024-switch/des-5024-switch_user-manual_76459039.webp)
Fast Ethernet Switching System User’s Guide
Managing the DES-5024
31
Local Console Management
Local Console Management is always done through the RS-232 serial port and requires a
direct connection between the DES-5024 and a PC. This type of management is very
useful when the network is down and the DES-5024 cannot be reached by any other
means.
Use Local Console Management to log into the DES-5024 for the first time. You do not
need to know the IP address to log into the DES-5024 using Local Console Management.
You can change all the settings and configure the DES-5024, set the IP address and
perform other management functions. The management session will timeout after five
minutes if you have not taken any action. Press enter a few times to refresh the screen.
You will have to log in again after a timeout.
Follow these steps to begin a management session using Local Console Management:
1. Attach the male end of the RS-232 serial cable provided with the DES-5024 to the
RS-232 port located at the front of the DES-5024.
2. Attach the other end to the serial port of a PC or workstation.
3. Run a terminal emulation program using the following settings:
•
Emulation:
VT-100/ANSI compatible
•
BPS:
19 200
•
Data bits:
8
•
Parity:
None
•
Stop bits:
1
•
Flow Control:
None
•
Enable:
Terminal keys
4.
Press Enter to display the login panel.
5. Log in using the default User Name and Password. The User Name and Password are
case sensitive.
•
User Name:
D-Link
•
Default Password:
D-Link
5.