Q:Is there port cannot be set to port trunking for DES-3224 and DES-5024?

Yes, there are some port in the switch cannot be set to port trunking.

For DES-5024, port 5/6/7/8 and port 17/18/19/20 are not the first ports of the PSP, these ports cannot be selected as part

of the trunk group.

For DES-3224, port 3/4, 11/12, 15/16 and 23/24 cannot be selected as part of the trunk group.

Q:Is there any limitation for setting port trunking in DES-1016?

Yes, DES-1016 totally support four trunk groups, it ONLY allow user to set 4 port as a trunk group.

Reference

1. IBM Ethernet Workgroup Switch Raven/Cardinal(DES-5024,DES-3224) Software

Functional Specification. Draft v1.02

2. D-Link DES-1016 Software Internal specification

Summary of Contents for DES-3224 - Switch

Page 1: ...l switch and NIC Cisco switch Bay Switch Bay 350T f w 2 0 Q How s the compatibility for those products It s currently Very poor That s why 3Com Bay Cisco Sun want to propose their standard in IEEE 802 3ad study group The interoperability problem will be solved after the standard is finalized Q What vendor support trunking function on their Server card 1 How many vendors have this 3Com Intel 2 How ...

Page 2: ...ture Q What s the benefit of choicing 4 port server NIC instead of Gigabit NIC User can use current Fast Ethernet technology to enjoy the high bandwidth 800Mbps max near Gigabit Ethernet Technical Q How does the port trunking function work in DES 5024 and DES 3224 The DES 5024 and DES 3224 support port trunking feature If there are more than two switches connected together the switches can be conn...

Page 3: ...user don t need to enable port trunking function on the switch site Q What is the difference between the application of trunking and the stackability of switches The trunking function might be able to compete with stackable switches The stackable switch using additional interface to cascade several LAN switch together it basically is a proprietary solution Most of stackable switch vendor will char...

Page 4: ...ted as part of the trunk group For DES 3224 port 3 4 11 12 15 16 and 23 24 cannot be selected as part of the trunk group Q Is there any limitation for setting port trunking in DES 1016 Yes DES 1016 totally support four trunk groups it ONLY allow user to set 4 port as a trunk group Reference 1 IBM Ethernet Workgroup Switch Raven Cardinal DES 5024 DES 3224 Software Functional Specification Draft v1 ...