Page 1: ...D Link DES 1316 Web Smart 8 Port 10 100Mbps Ethernet Switch with 8 10 100Mbps 802 3af Power Over Ethernet Ports Manual First edition Building Networks for People ...

Page 2: ...required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Warnung Dies ist ein Produkt der Klasse A Im Wohnbereich kann dieses Produkt Funkstoerungen verursachen In diesem Fall kann vom Benutzer verlangt werden angemessene Mass...

Page 3: ...rodotto appartiene alla classe A Se utilizzato in ambiente domestico il prodotto può causare interferenze radio nel cui caso è possibile che l utente debba assumere provvedimenti adeguati VCCI Warning BSMI Warning 3 ...

Page 4: ...Network 8 Power over Ethernet PoE 9 Features 9 Unpacking and Installation 11 Unpacking 11 Installation 11 Rack Mounting 12 Connecting Network Cable 13 AC Power 13 Identifying External Components 14 Front Panel 14 Rear Panel 15 Understanding LED Indicators 16 Power and CPU LEDs 16 Ports 1 8 PoE port status LEDs 16 Ports 9 16 Ethernet port status LEDs 17 ...

Page 5: ...ing the Switch 26 Login 27 Setup Menu 30 Configuring Setup Setting 31 Port Settings 31 VLAN Settings Virtual Local Area Network 33 Trunk Setting 35 Mirror Setting 36 PoE Setting 37 Device Status 39 Statistic 40 System Setting 42 Trap Setting 43 Set Password 44 Backup Setting 45 Reset Setting 46 Logout 46 Technical Specifications 48 ...

Page 6: ... Port 1 to Port 8 The Switch provides 15 4Watts per port and can be connected to WLAN access point IP phone video camera and other PD devices The Switch will automatically detect the network appliance s requirements and the Switch will supply the required power current to each appliance Purpose This guide discusses how to install your Web Smart16 Port 10 100Mbps Ethernet Switch Terms Usage In this...

Page 7: ...olution nature and the dominating potential market base virtually guarantees cost effective and high performance Fast Ethernet solutions 100Mbps Fast Ethernet is a standard specified by the IEEE 802 3 LAN committee It is an extension of the 10Mbps Ethernet standard with the ability to transmit and receive data at 100Mbps while maintaining the CSMA CD Ethernet protocol Since the 100Mbps Fast Ethern...

Page 8: ...pter cards Switching LAN technology is a marked improvement over the previous generation of network bridges which were characterized by higher latencies Routers have also been used to segment local area networks but the cost of a router the setup and maintenance required make routers relatively impractical Today switches are an ideal solution to most kinds of local area network congestion problems...

Page 9: ...same cable Supporting category 5 5e up to 100 Meters PoE will provide power to PoE compatible device such as IP telephones wireless LAN access points and IP security cameras PoE is already widely adopted in the market saving up to 50 of overall installation costs by eliminating the need to install separate electrical wiring and power outlets Features 16 10 100Mbps Auto negotiation Fast Ethernet RJ...

Page 10: ...g 512KBytes packet buffer Supports IEEE 802 3x flow control for full duplex mode ports Supports Back pressure flow control for half duplex mode ports Supports 802 1Q VLAN Supports Port based Trunking Supports Port mirroring Supports Port setting for Speed Disable Flow control and Port based QoS Quality of Service Easy configuration via Web Browser Easy setting via Web Management Utility Standard 1...

Page 11: ...r shock cushioning Screws and two mounting brackets CD ROM with Web Management Utility and Manual If any item is found missing or damaged please contact your local reseller for replacement Installation The site where you install the hub stack may greatly affect its performance When installing consider the following pointers Install the Switch in a fairly cool and dry place See Technical Specificat...

Page 12: ...r feet to the bottom of each device The rubber feet cushion the hub and protect the hub case from scratching Rack Mounting The Switch can be mounted in an EIA standard size 19 inch rack which can be placed in a wiring closet with other equipment Attach the mounting brackets at the Switch s front panel one on each side and secure them with the provided screws Figure 1 Combine the Switch with the pr...

Page 13: ...r network The Switch supports 10Mbps Ethernet or 100Mbps Fast Ethernet and it runs both in half and full duplex mode using two pairs of Category 5 cables These RJ45 ports are Auto MDI type port The Switch can auto transform to MDI II or MDI X type so you can just make an easy connection that without worrying if you are using a standard or crossover RJ45 cable AC Power The Switch uses the AC power ...

Page 14: ...e terminal is identified and the Switch will supply power through the Ethernet port to the connected PoE device For Legacy devices that are not yet compatible the PoE port will not offer the power to these devices This feature allows users to freely and safely mix legacy and Power over LAN compatible devices on their network These ports support network speeds of either 10Mbps or 100Mbps and can op...

Page 15: ... When the port is set to Forced Mode Auto MDI MDIX will be disabled Rear Panel AC Power Connector Reset Button Figure 4 Rear panel of the Switch AC Power Connector This is a three pronged connector that supports the power cord Plug in the female connector of the provided power cord into this connector and the male into a power outlet Supported input voltages range from 100 240V AC at 50 60Hz Reset...

Page 16: ...ff When the Power turns off or the power cord has improper connection CPU Management Indicator Blinking When the CPU is working the CPU LED is blinking On Off The CPU is not working Ports 1 8 PoE port status LEDs Link ACT Link Activity On When the Link ACT LED lights on the respective port is successfully connected to an Ethernet network Blinking When the Link ACT LED is blinking the port is trans...

Page 17: ... PoE Power over current PoE Power fault Off No Powered Device is detected Ports 9 16 Ethernet port status LEDs Link ACT Link Activity On When the Link ACT LED lights on the respective port is successfully connected to an Ethernet network Blinking When the Link ACT LED is blinking the port is transmitting or receiving data on the Ethernet network Off There is no link 100Mbps On When the 100Mbps LED...

Page 18: ...nagement Utility The following instructions guide you through the installation of the Web Management utility 1 Insert the Utility CD in the CD ROM Drive 2 From the Start menu on the Windows desktop choose Run 3 In the Run dialog box type D Web Management Utility setup exe D depends where your CD ROM drive is located and click OK 4 Follow the on screen instructions to install the utility 5 Upon com...

Page 19: ...igure 6 Web Management Utility The Web Management Utility is divided into four parts Discovery List Monitor List Device Setting and Toolbar function for detailed instructions follow the section below 19 ...

Page 20: ... button to select a device from the Discovery List to the Monitor List System word definitions in the Discovery List MAC Address Shows the device MAC Address IP Address Shows the current IP address of the device Protocol version Shows the version of the Utility protocol Product Name Shows the device product name System Name Shows the appointed device system name Location Shows where the device is ...

Page 21: ...is not alive IP Address Shows the current IP address of the device MAC Address Shows the device MAC Address Protocol version Shows the version of the Utility protocol Product Name Shows the device product name System Name Shows the appointed device system name Location Shows where the device is located Trap IP Shows the IP where the Trap is to be sent Subnet Mask Shows the Subnet Mask set of the d...

Page 22: ...s been transmitted reminding us to view the trap Figure 7 Figure 7 When the View Trap button is clicked a Trap Information window will pop up It will display the trap information including the Symbol Time Device IP and the Event occurred Figure 8 The symbol represents the trap signal this symbol will disappear after you review and click on the event record Figure 8 22 ...

Page 23: ... in the Monitor List Device Setting You can set the device by using the function key in the Device Setting Dialog box Configuration Setting In this Configuration Setting you can set the IP Address Subnet Mask Gateway Set Trap to Trap IP Address System name and Location Select the device in the Discovery list or Monitor List and press this button then the Configuration Setting window will pop up Fi...

Page 24: ...sword Fill in the required passwords in the dialog boxes and press the Set button to process the password change immediately Figure 10 Password Change Firmware Upgrade When the device has a new function there will be a new firmware to update the device use this function to upgrade the firmware 24 ...

Page 25: ...the device in the Monitor List or select a device in the Monitor List and press the Web Access button to access the device in Web browser Toolbar The toolbar in the Web Management Utility has four main tabs File View Options and Help 25 ...

Page 26: ...ns the view log function will help you display trap settings View Log To display the event of the Web Management Utility and the device Clear Log To clear the log In the Option TAB there is the Refresh Time function This function helps you to refresh the time for monitoring the device Choose 15 secs 30 secs 1 min 2 min and 5 min to select the time for monitoring In the Help TAB there is About func...

Page 27: ...itch is configured through an Ethernet connection make sure the manager PC is set on same the IP network For example when the default network address of the default IP address of the Web Smart Switch is 192 168 0 1 then the manager PC should be set at 192 168 0 x where x is a number between 2 and 254 and the default subnet mask is 255 255 255 0 Open Internet Explorer 5 0 or above Web browser Enter...

Page 28: ...nitor List of the Web Management Utility to settle the device on the Web Browser When the following dialog page appears enter the default password admin and press Login to enter the main configuration window Figure 13 After entering the password the main page appears and the screen will display the device status 28 ...

Page 29: ...Figure 14 Device Status 29 ...

Page 30: ... on the setup item that you want to configure There are eleven options Port Settings VLAN Settings Trunk Settings Mirror Settings PoE Settings Device Status Statistic System Settings Trap Setting Password Settings Backup Settings and Reset Settings as shown in the Main Menu screen Figure 15 Setup menu 30 ...

Page 31: ...16 this page will display each port s status Press the ID parameter to set each port s Speed Flow Control Rate Control Ingress and Egress When you need to renew the posted information press the Refresh button The Link Status in the screen will display the connection speed and duplex mode otherwise this dialog box will display down when the port is disconnected Figure 16 Port Configuration 31 ...

Page 32: ...tting has six modes 100M Full 100M Half 10M Full 10M Half Auto and Disable for speed or port disable selections Flow Control This setting determines whether or not the Switch will be handling flow control Set FlowCtrl to Enable for avoiding data transfer overflow If it is set to Disable there is either no flow control or other hardware software management 32 ...

Page 33: ... for a single switch or for multiple switches When you create a VLAN you can control traffic flow and ease the administration of moves adds and changes on the network by eliminating the need to change physical cabling On VLAN settings there are two main settings VID Table Setting and Port VLAN Setting VID Select the VID group that you set When you select VID Table Setting press Add new VID to crea...

Page 34: ...Figure 18 34 ...

Page 35: ...ity value between 0 and 7 Figure 19 Trunk Setting The Trunk function enables the Switch to cascade two devices with double the bandwidth up to 1600Mbps in full duplex mode There are 3 selections for the trunk setting port 09 10 port 09 10 11 12 or select disable for closing this function 35 ...

Page 36: ...can be studied It enables the manager to keep close track of switch performance and alter it if necessary Configuring the port mirroring by assigning a source port from which to copy all packets and a sniffer port where those packets will be sent The selections of the sniffer mode is as follows TX transmit mode This mode will duplicate the data transmitted from the source port and forward it to th...

Page 37: ...d from and data sent to the source port then it will forward the data to the sniffer port Figure 21 PoE Setting When you click on the PoE Setting the status of the PoE will appear on the screen it will display the PoE Enable Power W Voltage V Current mA classification and Status 37 ...

Page 38: ... refresh the status of the PoE Press SetPoE button to configure the PoE Port setting select enable to activate the PoE function from port 1 to port 8 and disable to deactivate the PoE function Click the Apply button to save the settings 38 ...

Page 39: ...s button to display the device status on this screen It will display the System Status Port Status VLAN Status Trunk Status Mirror Status QoS Status and PoE Status Press Refresh when you need to renew the posted information Figure 24 Status 39 ...

Page 40: ...Statistic The Statistics Menu screen will display the status of each port packet count Figure 25 Statistic 40 ...

Page 41: ...For detailed packet information click on the ID parameter as Figure 26 Figure 26 41 ...

Page 42: ...ty you can easily recognize the device by using the System Name and the Location Name The Login Timeout is to set the idle time out for security issues When there is no action when running the Web Smart Utility and the it times out you must re login to Web Smart Utility before you set the Utility Fill in the IP Address Subnet Mask and Gateway for the device Figure 27 42 ...

Page 43: ...ap Setting enables the device to monitor the Trap through the Web Management Utility Set the Trap IP Address of the manager where the trap is to be sent Figure 28 Trap Setting System Events Monitoring the system s trap 43 ...

Page 44: ...transmit data error in copper port Abnormal 50 error packet count within 10 seconds PoE Events Monitoring the PoE ports status PoE Power fail A trap when the port s power source fails or the PD64012 fails Power on Power down A trap when the PoE port s power is on and down Power over current A trap when the PoE port s power is over current Power short circuit A trap when the PoE port s power circui...

Page 45: ...tored to the default setting Figure 29 Set Password Backup Setting The backup tools help you to backup the current setting of the Switch Once you need to backup the setting press the Backup button to save the setting To restore a current setting file to the device you must specify the backup file and press the Restore button to process the setting of the recorded file 45 ...

Page 46: ...on helps you to reset the device back to the default setting from the factory Be aware that the entire configuration will be reset the IP address of the device will be set to the default setting of 192 168 0 1 Figure 31 Reset Setting Logout When you select this function the Web configuration will log out and return to first Login page 46 ...

Page 47: ...Figure 32 Logout 47 ...

Page 48: ...00Mbps full duplex Topology Star Network Cables 10BASET 2 pair UTP Cat 3 4 5 up to 100m 100BASE TX 2 pair UTP Cat 5 up to 100m Number of Ports 8 x 10 100M PoE Ethernet ports port 1 port 8 8 x 10 100M Ethernet ports port 9 port 10 Power over Ethernet Standard IEEE 802 3af Power current Up to 15 4W per port PD Classification Auto PD classification identify PoE pin assignment Power pin 3 pin 6 in RJ4...

Page 49: ...idity Operating 10 90 Storage 5 90 Dimensions 440 x 140 x 44 mm W x H x D 17 3 x 5 5 x 1 7 in EMI FCC Class A CE Mark Class A VCCI Class A Safety cUL UL60950 CB IEC60950 Performance Transmits Method Store and forward Filtering Address Table 4K entries per device Packet Filtering Forwarding Rate 10Mbps Ethernet 14 880 pps 100Mbps Fast Ethernet 148 800 pps MAC Address Learning Automatic update Trans...

Page 50: ...ängeren Zeitraum nicht benutzt sollten Sie es vom Stromnetz trennen Somit wird im Falle einer Überspannung eine Beschädigung vermieden 13 Durch die Lüftungsöffnungen dürfen niemals Gegenstände oder Flüssigkeiten in das Gerät gelangen Dies könnte einen Brand bzw Elektrischen Schlag auslösen 14 Öffnen Sie niemals das Gerät Das Gerät darf aus Gründen der elektrischen Sicherheit nur von authorisiertem...

Page 51: ...warrants each of its hardware products to be free from defects in workmanship and materials under normal use and service for a period commencing on the date of purchase from D Link or its Authorized Reseller and extending for the length of time stipulated by the Authorized Reseller or D Link Branch Office nearest to the place of purchase If the product proves defective within the applicable warran...

Page 52: ... product which substantially conforms to D Link s applicable product documentation Purchaser assumes responsibility for the selection of appropriate application and system platform software and associated reference materials D Link makes no warranty that its software products will work in combination with any hardware or any application or system platform software product provided by any third par...

Page 53: ...able of correction or if D Link determines in its sole discretion that it is not practical to repair or replace the defective Hardware the price paid by the original purchaser for the defective Hardware will be refunded by D Link upon return to D Link of the defective Hardware All Hardware or part thereof that is replaced by D Link or for which the purchase price is refunded shall become the prope...

Page 54: ...ackages will be shipped to the customer via UPS Ground or any common carrier selected by D Link with shipping charges prepaid Expedited shipping is available if shipping charges are prepaid by the customer and upon request D Link may reject or return any product that is not packaged and shipped in strict compliance with the foregoing requirements or for which an RMA number is not visible from the ...

Page 55: ...Link Systems Inc Other trademarks or registered trademarks are the property of their respective manufacturers or owners Copyright Statement No part of this publication or documentation accompanying this Product may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from D Link Corporation D Link Systems Inc a...