Cable Quality 

For all connections to the Switch, use these rules for cable selection: 

For connections to 10BASE-T and 100BASE-TX devices, use Category 5 or 5e UTP/STP cable.

For connections to 100BASE-TX and 1000BASE-T devices, use Category 5e or better UTP/STP cable.

All 1000BASE-T connections will operate in full duplex mode.

Connect to an End Node 

End nodes include PCs outfitted with a 10, 100 or 1000 Mbps RJ-45 Ethernet/Fast Ethernet Network 

Interface Card (NIC) and Ethernet-ready routers. Use standard Ethernet cables to connect the Switch to end 

nodes. The Switch port will automatically adjust to the hardware characteristics (MDI/MDIX, speed, duplex) 

of the device to which it is connected.  

Switch connected to an end node 

Observe the guidelines for cable quality stated at the beginning of this section. The

 Link/Act/Speed 

LEDs

 

for ports 1  to 16 lights green when the link is valid. The LEDs for ports 17 to 18 lights up amber at 10/100 

Mbps and green at 1000 Mbps. 

Connect to a Hub or Switch 

Connect to another switch or hub  

NOTE:

 All Ethernet ports auto-detect MDI/MDIX, port 

speed (10, 100, 1000 Mbps) and duplex of the device 

connected to the Switch. 

NOTE:

 UTP (Unshielded Twisted Pair) Ethernet 

cabling is adequate for most small office environments. 

More expensive STP (Shielded Twisted Pair) can also 

be used, but is generally only needed when there will 

be risk of strong electromagnetic interference due to 

radio frequencies. 

Summary of Contents for DES-1018MP

Page 1: ...3 ...

Page 2: ...emperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature Tmra b Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised c Mech...

Page 3: ...ng the Rubber Feet 7 Provide for Adequate Ventilation 7 Step 4 Power on the Switch 7 Power Failure 7 Step 5 Connecting the Switch 7 Connect to an End Node 8 Connect to a Hub or Switch 8 Connect to Network Backbone or Server 9 Understanding The Switch Features 10 PoE Rule 10 Power Saving 10 Appendix A Technical Specifications 11 Hardware Specifications 11 Key Components Performance 11 Port Function...

Page 4: ...potential property damage or personal injury Copyright and Trademarks Information in this document is subjected to change without notice 2014 D Link Corporation All rights reserved Reproduction in any manner whatsoever without the written permission of D Link Corporation is strictly forbidden Trademarks used in this text D Link and the D LINK logo are trademarks of D Link Corporation Microsoft and...

Page 5: ...on This simplicity is useful for SOHO and SMB users who have limited budgets but require PoE capability in a switch Product Outlook Front Panel Figure 1 DES 1018P MP Front Panel LEDs LED Color Status Description Power Green Solid light Power on Off Power off Link Act Speed 10 100 1000BASE T SFP Ports Ports 17 to 18 Green Solid light Secure connection to a 1000 Mbps Ethernet device is established B...

Page 6: ...to a PoE device and is powering the device properly Red Solid light The PoE port has failed possibly due to 1 PoE total power budget shortage 2 Over current Exceeds the power current of powered device s classification 3 Short circuit An intentional short circuit has been performed on a powered device Off Light off No connection to a PoE device Rear Panel Figure 2 DES 1018P MP Rear Panels Power Cor...

Page 7: ...ower supply and system a 12 to 6 AWG copper conductor is required for U S installation Commercially available 6 AWG wire is recommended The length of the cable depends on the proximity of the Switch to proper grounding facilities A screwdriver not included in the accessory kit The following steps let you connect the switch to a protective ground 1 Verify if the system power is off 2 Use the ground...

Page 8: ...se follow the steps below to set up the Switch 1 Install the DES 1018P MP in a cool and dry place Refer to the Technical Specifications for the acceptable operating temperature and humidity ranges 2 Install the Switch in a site free from strong electromagnetic source vibration dust and direct sunlight 3 Leave at least 10 cm of space at the left and right hand side of the Switch for ventilation 4 V...

Page 9: ...ly while the system resets Power Failure As a precaution in the event of a power failure unplug the Switch When power is resumed plug the Switch back in Step 5 Connecting the Switch Users can attach IEEE 802 3af compliant devices to the PoE ports on the DES 1018P MP by plugging in an Ethernet cable Switch to End Node Switch to Hub or Switch Connecting to a Server CAUTION Do not place any devices o...

Page 10: ...to the hardware characteristics MDI MDIX speed duplex of the device to which it is connected Switch connected to an end node Observe the guidelines for cable quality stated at the beginning of this section The Link Act Speed LEDs for ports 1 to 16 lights green when the link is valid The LEDs for ports 17 to 18 lights up amber at 10 100 Mbps and green at 1000 Mbps Connect to a Hub or Switch Connect...

Page 11: ... Connect to Network Backbone or Server Ports 17 to 18 may be used to uplink the Switch to a network backbone or network server When linking to a 1000BASE T device the port operates in full duplex mode Connection to a Server Observe the guidelines for cable quality stated at the beginning of this section The Link Act Speed LEDs for ports 1 to 16 lights green when the link is valid The LEDs for port...

Page 12: ...uard Band DES 1018P MP has reserved a 3 watt Guard Band to prevent the power supply from exceeding the PoE power budget When the current PoE output has reached 80 or 246 4 watts the Power Max LED will light up and the Switch will check the priority of each PoE port In the meantime if a new PoE device is connected the Switch will cut off the power of the port with a higher port number Power Saving ...

Page 13: ...low control IEEE 802 3z IEEE 802 3az IEEE 802 3af Physical Environment Dimensions 280 mm x 210 mm x 44 mm Internal Power Supply AC input 100 240 VAC 50 60Hz Acoustic DES 1018P 38dB DES 1018MP 36 8 dB A at low speed 51 8 dB A at high speed Operation Temperature 0 40 C Storage Temperature 40 70 C Operation Humidity 0 95 RH Storage Humidity 0 95 RH Emission EMI Certifications FCC class A CE Class A V...

Page 14: ......

Reviews: