background image

D-Link DES-1018DG Unmanaged Gigabit Ethernet Switch

 

 

 

 

          

22 

Summary of Contents for DES-1018DG

Page 1: ...D Link DES 1018DG 16 Port 10 100Mbps 2 Port Gigabit Ethernet Switch Manual First Edition Building Networks for People RECYCLABLE ...

Page 2: ...radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this produ...

Page 3: ...D Indicators 3 REAR PANEL DESCRIPTION 4 INSTALLATION 5 Package Contents 5 BEFORE YOU CONNECT TO THE NETWORK 5 ATTACHING THE RUBBER FEET 5 PROVIDE FOR ADEQUATE VENTILATION 7 POWER ON 7 Power Failure 7 CONNECTING THE SWITCH 9 SWITCH TO END NODE 9 SWITCH TO HUB OR SWITCH 10 CONNECTING TO NETWORK BACKBONE OR SERVER 10 TECHNICAL SPECIFICATIONS 11 GLOSSARY 12 WARRANTY AND REGISTRATION INFORMATION 17 ALL...

Page 4: ...b switch or backbone server Appendix A Technical Specifications The technical specifications of the DES 1018DG Glossary Lists definitions for terms and acronyms used in this document Index Index of relevant terms in the DES 1018DG Manual Intended Readers The DES 1018DG Manual contains information for setup and management and of the DES 1018DG switch This guide is intended for network managers fami...

Page 5: ...n you follow the operating instructions Keep your system away from radiators and heat sources Also do not block cooling vents Do not spill food or liquids on your system components and never operate the product in a wet environment If the system gets wet see the appropriate section in your troubleshooting guide or contact your trained service provider Do not push any objects into the openings of y...

Page 6: ...low your local national wiring rules When connecting or disconnecting power to hot pluggable power supplies if offered with your system observe the following guidelines Install the power supply before connecting the power cable to the power supply Unplug the power cable before removing the power supply If the system has multiple sources of power disconnect power from the system by unplugging all p...

Page 7: ...ority or an electrician if you are uncertain that suitable grounding is available CAUTION The system chassis must be positively grounded to the rack cabinet frame Do not attempt to connect power to the system until grounding cables are connected Completed power and safety ground wiring must be inspected by a qualified electrical inspector An energy hazard will exist if the safety ground cable is o...

Page 8: ...e users use applications that generate more traffic Upgrading key components such as your backbone and servers to Gigabit Ethernet can greatly improve network response times as well as significantly speed up the traffic between your subnetworks Gigabit Ethernet enables fast optical fiber connections to support video conferencing complex imaging and similar data intensive applications Likewise sinc...

Page 9: ...dule is equipped with 16 ports providing dedicated 10 100Mbps and 2 ports 10 100 1000Mbps bandwidth These ports can be used for connecting PCs servers and hubs The DES 1018DG uses standard twisted pair cabling and are ideal for segmenting networks into small connected subnets This stand alone Switch enables the network to use some of the most demanding multimedia and imaging applications concurren...

Page 10: ...tatus of the network A description of these LED indicators follows see LED Indicators The LED indicators of the Switch include Power Link Act and speed Power Indicator This green indicator illuminates when the Switch is receiving power Link Act This green indicator illuminates steadily when a port is connected to a station successfully and has a good link The indicator will blink to indicate that ...

Page 11: ...hese ports support network speeds of either 10Mbps or 100Mbps and can operate in half and full duplex transfer modes These ports also support automatic MDI MDI X crossover detection giving true plug and play capability Just plug the network cable directly into the hub you can use either straight through or crossover cable 1000BASE T Ports Port 17 18 The DES 1018DG is equipped with two Gigabit twis...

Page 12: ...t at least 3 kg of weight Do not place heavy objects on the Switch The power outlet should be within 1 82 meters 6 feet of the Switch Visually inspect the power cord and see that it is fully secured to the AC power port Make sure that there is proper heat dissipation from and adequate ventilation around the switch Leave at least 10 cm of space at the front and rear of the Switch for ventilation In...

Page 13: ...D Link DES 1018DG Unmanaged Gigabit Ethernet Switch Figure 2 2 Attaching the Rubber Feet 6 ...

Page 14: ...at generates a significant amount of heat For the Switch to perform at its optimal level the Switch must have adequate ventilation to prevent the Switch from overheating and becoming damaged Power On Plug one end of the AC to DC power converter into the power connector of the Switch and the other end into the local power source outlet After the Switch is powered on the LED indicators will momentar...

Page 15: ...D Link DES 1018DG Unmanaged Gigabit Ethernet Switch 8 ...

Page 16: ...or 1000 Mbps RJ 45 Ethernet Fast Ethernet Network Interface Card NIC and most routers An end node can be connected to the Switch via a twisted pair Category 3 4 or 5 UTP STP cable The end node can be connected to any of the ports of the Switch Figure 3 1 Switch connected to an end node The Link Act LEDs for each UTP port light green when the link is valid The LED over the port label indicates a po...

Page 17: ...d to the Switch via a twisted pair Category 5 UTP STP cable A 1000BASE T switch can be connected to the Switch via a twisted pair Category 5e UTP STP cable Figure 3 2 Switch connected to a port on a hub or switch using either a straight or crossover cable any normal cable is fine Connecting To Network Backbone or Server Any of the Gigabit Ethernet ports are ideal for uplinking to a network backbon...

Page 18: ... UTP Cat 5e Unshield Twisted Pair UTP Cable Number of Ports 16 10 100BASE TX Fast Ethernet ports 2 1000BASE T Gigabit Ethernet ports Physical and Environmental DC Inputs 5V 3A Power Consumption 9 25 watts maximum Operating Temperature 32 F 131F 0 C 55 Storage Temperature 14 F 158 F 10 C 70 C Humidity 5 95 RH non condensing Dimensions 9 21 in x 6 18 in x 1 77 in 234 mm x157 mm x 45 mm EMI FCC Class...

Page 19: ... network segments BOOTP The BOOTP protocol allows you to automatically map an IP address to a given MAC address each time a device is started In addition the protocol can assign the subnet mask and default gateway to a device bridge A device that interconnects local or remote networks no matter what higher level protocols are involved Bridges form a single logical network centralizing network admi...

Page 20: ...s that can be configured so that one will take over data transmission should the other fail See also main port and standby port RJ 45 Standard 8 wire connectors for IEEE 802 3 10BASE T networks RMON Remote Monitoring Subset of SNMP MIB II which allows monitoring and management capabilities by addressing up to ten different groups of information RPS Redundant Power System A device that provides a b...

Page 21: ...ram to an application program on another device VLAN Virtual LAN A group of location and topology independent devices that communicate as if they are on a common physical LAN VLT Virtual LAN Trunk A Switch to Switch link which carries traffic for all the VLANs on each Switch VT100 A type of terminal which uses ASCII characters VT100 screens have a text based appearance 14 ...

Page 22: ...ink s functional specifications for the Software or to refund at D Link s sole discretion Except as otherwise agreed by D Link in writing the replacement Software is provided only to the original licensee and is subject to the terms and conditions of the license granted by D Link for the Software Software will be warranted for the remainder of the original Warranty Period from the date or original...

Page 23: ...ELATING TO WARRANTY SERVICE OR ARISING OUT OF ANY BREACH OF THIS LIMITED WARRANTY EVEN IF D LINK HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES THE SOLE REMEDY FOR A BREACH OF THE FOREGOING LIMITED WARRANTY IS REPAIR REPLACEMENT OR REFUND OF THE DEFECTIVE OR NON CONFORMING PRODUCT THE MAXIMUM LIABILITY OF D LINK UNDER THIS WARRANTY IS LIMITED TO THE PURCHASE PRICE OF THE PRODUCT COVERED BY TH...

Page 24: ...ioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen e Das Gerät ist gefallen und oder das Gehäuse ist beschädigt f Wenn das Gerät deutliche Anzeichen eines Defektes aufweist 16 Bei Reparaturen dürfen nur Orginalersatzteile bzw den Orginalteilen entsprechende Teile verwendet werden Der Einsatz von ungeeigneten Ersatzteilen kann eine weitere Beschädigung hervorrufen 17 Wenden Sie...

Page 25: ...suant to this warranty Any package returned to D Link without an RMA number will be rejected and shipped back to Purchaser at Purchaser s expense and D Link reserves the right in such a case to levy a reasonable handling charge in addition mailing or shipping costs Software Warranty service for software products may be obtained by contacting a D Link office within the applicable warranty period A ...

Page 26: ...na TEL 34 93 4090770 FAX 34 93 4910795 URL www dlinkiberia es Singapore 1 International Business Park 03 12 The Synergy Singapore 609917 TEL 65 6774 6233 FAX 65 6774 6322 URL www dlink intl com Australia 1 Giffnock Avenue North Ryde NSW 2113 Australia TEL 61 2 8899 1800 FAX 61 2 8899 1868 URL www dlink com au India D Link House Kurla Bandra Complex Road Off CST Road Santacruz East Mumbai 400098 In...

Page 27: ...ed Arab Emirates Tel 971 4 3916480 Fax 971 4 3908881 URL www dlink me com Turkey Regus Offices Beybi Giz Plaza Ayazaga Mah Meydan Sok No 28 Maslak 34396 Istanbul Turkiye TEL 90 212 335 2553 FAX 90 212 335 2500 URL www dlink com tr Egypt 19 El Shahed Helmy El Masri Al Maza Heliopolis Cairo Egypt TEL 202 414 4295 FAX 202 415 6704 URL www dlink me com China Room 507 508 Tower W1 The towers Oriental P...

Page 28: ...________________________________________________ 4 What network operating system s does your organization use D Link LANsmart Novell NetWare NetWare Lite SCO Unix Xenix PC NFS 3Com 3 Open Banyan Vines DECnet Pathwork Windows NT Windows 2000 Windows XP Others_____________________________________________________________________________ 5 What network management program does your organization use D V...

Page 29: ...D Link DES 1018DG Unmanaged Gigabit Ethernet Switch 22 ...

Reviews: