background image

DCH-122 PIR Motion Sensor  

                      

The   DCH-122   has   PIR   motion   sensor   function   in   one,   based   on  Z-

Wave

TM

 technology.

It   is   the  Z-Wave

TM

  plus   product,   it   support   the   security,   ...   Those

newest features of the  Z-Wave

TM

  technology.  Z-Wave

TM

  is a wireless

communication protocol designed for home automation, specifically to

remotely   control   applications   in   residential   and   light   commercial

environments. The technology uses a low-power RF radio embedded or

retrofitted into home electronics devices and systems, such as lighting,

home access control, entertainment systems and household appliances.

This product can be included and operated in any Z-Wave

TM

  network

with other Z-Wave

TM

 certified devices from other manufacturers and/or

other applications.  All non-battery operated nodes within the network

will act as repeaters regardless of vendor to increase reliability of the

network. 

The device adopt the Z-Wave

TM

  500 series chip, when your Z-Wave

TM

network   system   is   all   made   by   Z-Wave

TM

  500   series   devices.   The

network system will have the advantages as below.

Concurrent multi-channel support reduces external interference.

Better RF range, improve about 10 meters in indoor.

Support 100 Kbps transmit speed, speed up communication.

Add to/Remove from Z-Wave

TM

 Network

There are  two tamper  keys in the  device, one is in  the back side,

another is in the front side.  Both of them  can add, remove, reset or

association from Z-Wave

TM

 network.

In the first time, add the device into the Z-Wave

TM

 network.  First, 

make sure the primary controller is in the add mode. And then power 

on the device, just take out the insulation Mylar in the back side of the 

device. The device will auto start the NWI (Network Wide Inclusion) 

mode. And it should be included in 5 seconds. You will see the LED 

light ON one second.

Notice

: Including a node ID allocated by Z-Wave

TM

 Controller means 

Add

” or “

Inclusion

”.  Excluding a node ID allocated by Z-Wave

TM

  

Controller means “

Remove

” or “

Exclusion

”.

Function

Description

Add

1. Have Z-Wave

TM

 Controller entered inclusion mode.

2. Pressing tamper key three times within 1.5 seconds

to enter the inclusion mode.

3. After add successful, the device will wake to 

receive the setting command from Z-Wave

TM

 

Controller about 20 seconds.

1

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for DCH-122

Page 1: ...ow Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Add to Remove from Z WaveTM Network There are two tamper keys in the device one is in the back side another is in the front side Both of them can add remove reset or association from Z WaveTM network In the first time add the dev...

Page 2: ... to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the tamper key 3 times to abort the NWI mode Z WaveTM Notification After the device adding to the network it will wake up once per day in default When it wake up it will broadcast the Wake Up Notification message to the network and w...

Page 3: ...lue is 30 if setting to 1 that means the minimum auto report interval will be one minute And please notice if setting this value to zero that means disable all of the timing report except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flas...

Page 4: ...delay a while to turn OFF the lighting equipment The delay time is setting by the configuration NO 9 The PIR motion re detected interval in the Test Mode fixed to 6 seconds In the Normal Mode it according to the setting of the configuration NO 8 Notice When the tamper key of the back side is released the device always in the Test Mode no matter the DIP switch setting Battery Installation When the ...

Page 5: ...ing The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key pressed so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and decide to fix then you can remove tape A and mounting the sensor by using tape B The tamper key will pressed and let the sensor enter no...

Page 6: ...ns turn off illumination detected function And always turn on the light Notice In none test mode only the value in 1 to 99 will enable the illumination detected function and update the illumination value NO Name Def Vali d A B C Description 5 Operation Mode 0 All Operation mode Using bit to control Caution The value is unsigned byte the range is from 0x00 0xFF 0 Bit0 Reserve 0 Bit1 1 means test mo...

Page 7: ...f Vali d A B C Description received the trigger signal too frequently Also can save the battery energy Notice If this value bigger than the configuration setting NO 9 There is a period after the light turned off and the PIR not start detecting 9 Turn Off Light Time 4 0 127 After turn on the lighting setting the delay time to turn off the lighting when the PIR motion is not detected 8 seconds per t...

Page 8: ... use only Specifications subject to change without notice due to continuing product improvement FCC ID KA2CHZ122A1 IC ID 4216A CHZ122A1 Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable re...

Page 9: ...his device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any o...