background image

User’s Manual

Antes de utilizar el equipo, lea la sección 
“Precauciones  de  seguridad”  de  este 
manual.  Conserve  este  manual  para 
futuras consultas.
Before  operating  the  device,  please  read 
the  “Safety  precautions”  section  of  this 
manual.  Retain  this  manual  for  future 
reference.

VA series

Summary of Contents for VA-24T

Page 1: ...ipo lea la sección Precauciones de seguridad de este manual Conserve este manual para futuras consultas Before operating the device please read the Safety precautions section of this manual Retain this manual for future reference VA series ...

Page 2: ...CONFORMITY WARRANTY SAFETY PRECAUTIONS LINE DRAWINGS SYSTEM DESCRIPTION CONNECTION SPECIFICATIONS CONFIGURATION TROUBLESHOOTING INSTALLATION SYSTEM 6 4 5 3 Warning Description 6 7 8 10 11 14 9 13 Manual del Usuario VA series User s Manual ...

Page 3: ...n exposed to rain or moisture does not operate normally or has been dropped Equipo diseñado para funcionar entre 25ºC y 70ºC La humedad relativa máxima del 95 con 40ºC de temperatura ambiente Working temperature ranges from 25ºC to 70ºC The maximum relative humidity of 95 with ambient temperature 40ºC Equipo IP 54 según la norma IEC 60529 1989 M1 1999 IP 54 equipment IEC 60529 1989 M1 1999 No empl...

Page 4: ...prador en todos los casos Para solicitar reparación en garantía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All D A S products are warrantied against any manufacturing defect for a period of 2 years from date of purchase The warranty excludes damage from incorrect use of the product All warranty repairs must be exclusively u...

Page 5: ...nce with Harmonized European Norms l EN 60065 2002 A1 2006 A11 2008 A2 2010 A12 2011 Audio video and similar electronic apparatus Safety requirements l EN 54 24 2008 Fire detection and fire alarm systems Part 24 Components of voice alarm systems Loudspeakers Cumple con los objetivos esenciales de las Directivas Abide by essential objectives relating Directives l Low Voltage Directive 2006 95 EC l ...

Page 6: ...ides protection from dust and dirt A rotary switch and a multi tap transformer allow the user to choose among several output impedance solutions for the VA 4T 8 ohms 5W 100V line 10W 100V line 15W 100V line 2 5W 70V line 5W 70V line 7 5W 70V line for the VA 24T 8 ohms 10W 100V line 20W 100V line 30W 100V line 5W 70V line 10W 70V line 15W 70V line The cabinets are equipped with 4 M6 rigging points ...

Page 7: ...d as follows 1 Unscrew the four screws from the rear part of the enclosure removing the existing cable 2 Connect the new cables and adjust the rear cover in the holes as shown Make sure you connect the enclosure with the correct polarity 7 3 Fix the cover on the rear part of the enclosure with the four screws mentioned in the first step Manual del Usuario VA series User s Manual ...

Page 8: ... 4T and VA 24T include a transformer for use on 70V 100V distribution lines They can be also used as low impedance cabinets Use the switch to select the position that corresponds to the required power voltage line and impedance AMPLIFIER Remember to choose among the different power positions of the multi tap transformer For the VA 4T 8 ohms low impedance position 5W 100V line 10W 100V line 15W 100...

Page 9: ...CONFIGURATION AMPLIFIER Manual del Usuario VA series User s Manual 9 ...

Page 10: ... test described in 100 W 200 W 400 W 90 Hz 22 kHz 8 Ohms 7 8 Ohms 290 Hz Tap0 Low Z Tap1 10w Tap2 20w Tap3 30w 100V Tap0 Low Z Tap1 5w Tap2 10w Tap3 15w 70V 89 dB SPL 115 dB SPL 80º Horizontal x 70º Vertical High Impact ABS Black or White LF 2 x 4G 4G HF TWT 24 TWT 24 Spring Loaded Terminals 34 x 15 x 15 cm 17 7 x 5 9 x 5 9 in 2 6 kg 5 7 lb none AXU VA24 AXA AC 100 W 90 Hz 22 kHz Tap0 8 Ohms Tap1 ...

Page 11: ...nge without notice When flying a system the working load must be lower than the resistance of each individual flying point in the enclosure as well as each box Hanging hardware should be regularly inspected and suspect units replaced if in doubt This is important to avoid injury and absolutely no risks should be taken in this respect It is highly recommended that you implement an inspection and ma...

Page 12: ...the arms of the support Beware that the AXU support allows for an asymmetric arc install in the appropriate direction 5 Attach the unit to the support using the screws supplied but do not tighten 6 Aim the unit in the desired position and tighten screws Package contents 4x DIN 6912 M6x12 4x DIN 7980 M6 lock washer 4x DIN 7505 B 5X40 4x DIN 125A M5 flat washer 4x wall plugs nº7 Manual del Usuario V...

Page 13: ...Insert allen screws and lock washers selecting the angles provided between 0º and 42º in 6º steps Use the wide washer incl to supplement the distance between the last box and the AXA AC 4 Place the next box and the new AXA AC 5 Insert allen screws and lock washers selecting the angles provided between 0º and 42º in 6º steps 6 Repeat points 4 and 5 to add more boxes 7 Attach the AXU to the wall or ...

Page 14: ... 1 3 Check that there is a signal to your amplifier from your mixer 1 2 1 Check that the cable from the sound source to the UNIT is connected correctly Replace the cable if defective 1 2 2 Check that none of the connected cables are cut or frayed 1 3 1 Check the minimum impedance requirements of your amplifier 2 1 1 Check that the cable between the UNITS is connected correctly Replace the cable if...

Page 15: ...8DAS4USA Tel 1 305 436 0521 Fax 1 305 436 0528 D A S AUDIO ASIA PTE LTD 25 Kaki Bukit Crescent 01 00 02 00 Kaki Bukit Techpark 1 Singapore 416256 Tel 65 6742 0151 Fax 65 6742 0157 D A S AUDIO S A C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 96 134 0525 Tel Intl 34 96 134 0860 Fax 96 134 0607 Fax Intl 34 96 134 0607 ...