F)
SIGNAL
LED
These green LEDs show the presence of signal at the
amplifier's inputs, and is dependent on the position of the
LEVEL control.
G) COOLING AIR OUTLET GRILLES
Fan cooling permits airflow through the most vital parts of
the amplifier. Since the airflow finds its way out through
these grilles, keep them as clean and dust-free as possible
to assure proper cooling.
A) OUTPUT CONNECTIONS
Channel output connections to speakers is by binding
posts. PS-800 and PS-1400 models also provide Speakon
NL4 connections.
For the binding posts, polarity is clearly indicated by black
(–) and red (+) output terminals.
For the lower Speakon connector, pin assignments are:
Channel A : +1 / -1
Channel B : +2 / -2
Bridge : +1 / +2
For the Speakon situated on top, pin assignments are:
Channel B : +1 / -1
B) INPUTS
XLR and Jack inputs are connected in parallel.
Nominal input impedance is 20k ohm for balanced use and
10k ohm for unbalanced use.
Polarity complies with AES14-1992 (ANSI S4.48-1992) and
therefore pin assignments are:
1 or (Jack sleeve) = GND (Ground)
2 or (Jack Tip) = (+) non-inverted signal
3 or (Jack ring) = (–) inverted signal
C) INPUT MODE
This switch allows the selection of the input configuration
mode: stereo, parallel or bridge.
Typically the amplifiers are used in stereo mode, where the
input to channel A feeds channel A and the input to channel
B feeds channel B.
Parallel mode allows feeding both channels with the signal
plugged into channel A. Channel B's input isn’t
disconnected in this mode, therefore it can be used as a
link thru connection.
Bridge mode sums
both amplifier channels together, thus
doubling the output power. Refer to the “Bridge Mode
Operation” Appendix for further information.
D) INPUT SENSITIVITY SELECTOR
This selector allows to choose the input sensitivity 0.775V,
1.00V and 1.44V.
E) GROUND LOOP SELECTOR
The selector is used to avoid ground loops. Set the selector
in the “OFF” position when loops are detected.
F) MAINS LEAD
The mains lead is a connector type IEC320 terminated on a
plug.
If you need to cut off the plug to replace it for the type used
in your region, cable colour codes are brown (live), blue
(neutral) and yellow-green (earth). The appropriate fuse is
provided in the connector.
G) FAN INLET GRILLES
Like for the front outlet grilles, keep clean and dust-free to
assure free air intake for proper cooling.
REAR PANEL DESCRIPTION
B
A
G
F
STEREO
0.775V
ON
N1918
CH B INPUT
CH A INPUT
PARALLEL
1.0V
SENSITIVITY
BRIDGE
1.44V
OFF
CH A
CH B
BRIDGE
F
5A
L
250V
FUSE
GROUND S.N.
MODEL: PS-400
230V
50/60Hz 5A
OUTPUT PWR PER CH: 200W@4
D.A.S. AUDIO S.A. , SPAIN
MADE IN CHINA
GND
GND
COLD
COLD
HOT
HOT
2
3
1
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH THE SAME FUSE TYPE
SPEAKER OUTPUT
C
E
D
CH
B
CH
A
BRIDGE
CH A
CH B
BRIDGE
1+
2+
1+
1-
2-
2+
SPEAKER OUTPUT
WARNING: TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE
VER MANUAL DE INSTRUCCIONES PARA LA CONEXIÓN
REFER TO INSTRUCTIONS MANUAL FOR CONNECTION
ANSCHLUSSWEISE BITTE DER ANLEITUNG ENTNEHMEN
VOIR MANUEL D'INSTRUCTIONS POUR LA CONNEXION
CH A INPUT
CH B INPUT
D.A.S. AUDIO S.A. (VALENCIA) SPAIN
MADE IN CHINA
1.0V
STEREO
SENSITIVITY
MODE
GROUND
0.775V
BRIDGE
OFF
1.44V
PARALLEL
ON
S.N.
F 10A L 250V FUSE
MODEL: PS-800
230V
10A 50Hz/60Hz
OUTPUT PWR PER CH: 390W@4
FOR CONTINUED PROTECTION AGAINST RISK
OF FIRE REPLACE ONLY WITH THE SAME TYPE
CH B
1+ 1-
CAUTION
ATTENTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DANGER D’ELECTROCUTION
NE PAS OUVRIR
GND
COLD
HOT
GND
COLD
HOT
2
3
1
N1918
B
A
G
F
C
E
D
PS-800, PS-1400
PS-200, PS-400