background image

17

ANNEX I: Line connections: unbalanced and balanced

 

There are two basic ways to transport an audio signal with microphone or line level:

 

Unbalanced line: Utilising a two conductor cable, it transports the signal as the voltage between them. 

Electromagnetic  interference  can  get  added  to  the  signal  as  undesired  noise.  Connectors  that  carry 
unbalanced signals have two pins, such as RCA (Phono) and ¼” (6.35mm, often referred to as jack) mono. 3 
pin connector such as XLR (Cannon) may also carry unbalanced signals if one of the pins is unused.

 

Balanced line: Utilising a three conductor cable, one of them acts as a shield against electromagnetic 

noise and is the ground conductor. The other two have the same voltage with respect to the ground 
conductor but with opposite signs. The noise that cannot be rejected by the shield affects both signal 
conductors in the same way. At the device’s input the two signals get summed with opposite sign, so that 
noise is cancelled out while the programme signal doubles in level. Most professional audio devices use 
balanced inputs and outputs. Connectors that can carry balanced signal have three pins, such as XLR 
(Cannon) and ¼” (6.35mm) stereo.

 

The graphs that follow show the recommended connection with different types of connectors to balanced 

processor or amplifier inputs. The connectors on the left-hand side come from a signal source, and the ones 
on the right hand side go to the inputs of the processor or amplifier. Note that on the unbalanced connectors 
on the left-hand side, two terminals are joined in side the connector. If hum occurs with balanced to balanced 
connections, try disconnecting the sleeve (ground) on the input connector. Note that the illustrations show 
what should be connected to what, but that pin locations on an actual XLR connector are different. Also, pin 
2 hot is assumed on XLR connectors.

Manual del Usuario

 / LX series / 

User’s Manual

Summary of Contents for LX-218CA

Page 1: ...Manual Antes de utilizar el equipo lea la sección Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions section of this manual Retainthismanualforfuturereference series ...

Page 2: ...igging system 7 4 12 16 7 ANNEX I Line connections unbalanced and balanced ANNEX II DASnet cables 17 18 AMPLIFIER DESCRIPTION 8 11 LX 218CA vs LX 218CA NET Overheating ON OFF Preliminary Equalisation Overload indicators Low mains voltage Connections Current consumption Rain protector Troubleshooting Cardioid preset Manual del Usuario LX series User s Manual ...

Page 3: ...ct on an unstable cart stand tripod bracket or table The device may fall causing serious injury and serious damage to the device itself The appliance should be flown only from the rigging points and by qualified personnel Do not suspend the box from the handles and respect the maximium load values given in the manual Limpie con un paño seco No use limpiadores con disolventes Clean only with a dry ...

Page 4: ...eparación en garantía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All our products are warrantied against any manufacturing defect for a period of 2 years from date of purchase The warranty excludes damage from incorrect use of the product All warranty repairs must be exclusively undertaken by the factory or any of its autho...

Page 5: ...5032 2012 Electromagnetic compatibility of multimedia equipment Emission requirements l EN 55103 2 2009 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 2 Immunity l EN 50581 2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of...

Page 6: ...he dollies is three 3 The R versions are equipped with a front located dolly panel the PL LX218C which is attached by way of the rigging hardware Other interesting accessories have been compiled in the Table of Accessories graph below In the RIGGING SECTION more detail is provided for the accessories mentioned below The units incorporate a 2400 W Class D amplifier with switch mode power supply SMP...

Page 7: ...le Integrated in box design R version Audio INPUT Female XLR Audio LOOP THRU Male XLR AC INPUT powerCON Audio INPUT Female XLR Audio LOOP THRU Male XLR Audio Data INPUT etherCON Audio Data LOOP THRU etherCON AC INPUT powerCON TRUE1 Universal Mains 80 260 V dual voltage 900W 55x128x63 2 cm 55x135x69 6 cm R version 22x51x24 9 in 22x54x27 4 in R version 80 5 kg 99 5 kg R version 177 1 lb 218 9 lb R v...

Page 8: ... red 6 CARDIOID PRESET Button for switching between two types of response OMNIdirectional or CARDIOID 7 AC INPUT only LX 218CA PowerCon NAC3FCA connector to turn the unit ON or OFF inserted rotated and locked for ON Only use this equipment with an appropriate mains cord 7 AC INPUT only LX 218CA NET PowerCon TRUE1 connector to turn the unit ON or OFF inserted rotated and locked for ON Only use this...

Page 9: ...IT or CLIP LEDs that lights when the signal is excessive The indicator should not be lit continuously This distorts the signal quickly fatiguing your ears and may damage the speakers Therefore it is recommended that you never work with this LED on at most it should blink only occasionally Low mains voltage If mains voltage falls below the shutdown voltage for the unit it will stop playing When acc...

Page 10: ...the top side to allow convection cooling of the amplifier Rain protector for all versions of LX 218CA The most common use will be combined with the satellite system The use of an external delay to control and adjust the phase of the subs is recommended with a digital processor for example The SUB units are linked with the THRU option setting The OUTPUT and LOOP THRU connectors are output XLR type ...

Page 11: ...y high 2 Overheating 3 Overload or short circuit 4 DC at amplifier s output SOLUTION 1 Check that the mixer or sound source is sending signal to the UNIT 2 Check that the cable from the sound source to the UNIT is connected correctly Replace the cable if defective 3 Allow the unit to cool down for some minutes and it will function again Check the main output level of the mixer or channel gains sin...

Page 12: ...ch box Hanging hardware should be regularly inspected and suspect units replaced if in doubt This is important to avoid injury and absolutely no risks should be taken in this respect It is highly recommended that you implement an inspection and maintenance program on flying elements including reports to be filled out by the personnel that will carry out the inspections Local regulations may exist ...

Page 13: ...re fixed using high resistance quick release safety pins They have a centrally located reinforcement which is used to attach the lifting cables Depending on the position of the safety pins the array will achieve a different angle of inclination see the positions marked on the side panels The first box will be attached to this structure using 6 safety pins according to the procedure described on th...

Page 14: ...ferences and similarities OMNIDIRECTIONAL CARDIOID 3 4 Insert Pin Turn guide 5 Insert Pin 6 Raise cabinet 2 1 Join cabinets Turn guide 5 Insert Pin 2 1 Join cabinets Turn guide 4 3 Insert Pin Turn guide 6 Raise cabinet 7 Insert Pin Insert Pin 7 Manual del Usuario LX series User s Manual ...

Page 15: ... 18 14 14 17 17 12 12 15 15 11 11 14 14 10 10 12 12 8 8 10 10 6 6 8 8 LX LX æro æro MAX NUMBER OF UNITS ALLOWED MAX NUMBER OF UNITS ALLOWED FRONT FRONT REAR REAR Front located dolly platforms PL LX218C The front located dolly platforms are accessories available for the LX 218CA LX 218CA NET R versions include the front dolly These platform dollies are used for the transport of individual units and...

Page 16: ...S dolly panel for all versions of the model LX 218CA The caster kit will not impede cabinet stacking as the wheels are attached to the rear panel of the cabinet As a safety precaution when maneuvering cabinets the dolly panels should not exceed a maximum of three 3 units Manual del Usuario LX series User s Manual ...

Page 17: ...ors in the same way At the device s input the two signals get summed with opposite sign so that noise is cancelled out while the programme signal doubles in level Most professional audio devices use balanced inputs and outputs Connectors that can carry balanced signal have three pins such as XLR Cannon and 6 35mm stereo The graphs that follow show the recommended connection with different types of...

Page 18: ...al With each system cabling and patch panels are provided It is very important to use the system with the intended cables to prevent electromagnetic interferences between the analog audio signal the DASnet data and the power Be sure to check the specifications provided by the cable manufacturer It is also especially important when installing connectors yourself to note that when termination is not...

Page 19: ...888 DAS 4 USA DAS Audio Asia PTE LTD 3 Temasek Avenue Centennial Tower 34 36 Singapore 039190 Tel 65 6549 7760 DAS Audio Group S L C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 34 96 134 0860 DAS do Brasil LTDA Rua Dos Andradas 382 SL Santa Efigênia São Paulo Brasil CEP 01208 000 Tel 551133330764 ...

Reviews: