background image

3

action series

Precauciones de Seguridad
Safety Precautions

Cajas acústicas pasivas / Passive loudspeaker enclosures

Conserve y lea todas estas instrucciones.
Siga todas las advertencias.
El  signo  de  exclamación  dentro  de  un  triángulo  indica  la 
existencia  de  componentes  internos  cuyo  reemplazo  puede 
afectar a la seguridad.

Keep these instructions.
Heed all warnings. Follow all instructions.
The exclamation point inside an equilateral triangle indicates the 
existence of internal components whose substitution may affect 
safety.

El doble cuadrado indica equipo de Clase II.

The double square indicates Class II device.

Limpie con un paño seco. No use limpiadores con disolventes.

Las especificaciones se encuentran en la etiqueta de la parte 
posterior del producto.

The specifications can be found on the rear label of the product.

Clean  only  with  a  dry  cloth.  Do  not  use  any  solvent  based 
cleaners.

No existen partes ajustables por el usuario en el interior de este 
equipo.  Cualquier  operación  de  mantenimiento  o  reparación 
debe  ser  realizada  por  personal  cualificado.  Es  necesario  el 
servicio técnico cuando el aparato se haya dañado de alguna 
forma, tal como que haya caído líquido o algún objeto en el 
interior del aparato, haya sido expuesto a lluvia o humedad, no 
funcione correctamente o haya recibido un golpe.

No user serviceable parts inside. Refer all servicing to qualified 
service personnel. Servicing is required when the apparatus has 
been damaged in any way, such as power-supply cord or plug is 
damaged, liquid has been spilled or objects have fallen into the 
apparatus, the apparatus has been exposed to rain or moisture, 
does not operate normally or has been dropped.

action-8- 

------------->125 cm

action-12 

------------->115 cm

action-15 

------------->105 cm

action-8- 

------------->125 cm

action-12 

------------->115 cm

action-15 

------------->105 cm

Equipo diseñado para  funcionar  entre 15ºC  y 35ºC  con una 
humedad relativa máxima del 75%.

Working temperature ranges from 15ºC to 35ºC with a relative 
humidity of 75%.

No exponga este equipo a la lluvia o humedad. No exponga el 
equipo  a  salpicaduras  ni  coloque  sobre  él  objetos  que 
contengan líquidos, tales como vasos y botellas. Equipo IP-20.

Do not expose this device to rain or moisture.  Do not place any 
objects containing liquids, such as bottles or glasses, on the top 
of the unit. Do not splash liquids on the unit. IP-20 equipment.

No  emplace  altavoces  en  proximidad  a  equipos  sensibles  a 
campos  magnéticos,  tales  como  monitores  de  televisión  o 
material magnético de almacenamiento de datos.

Do not place loudspeakers in proximity to devices sensitive to 
magnetic  fields  such  as  television  monitors  or  data  storage 
magnetic material.

Este  símbolo  indica  que  el  presente  producto  no  puede  ser 
tratado  como  residuo  doméstico  normal,  sino  que  debe 
entregarse en el correspondiente punto de recogida de equipos 
eléctricos y electrónicos.

This symbol on the product indicates that this product should 
not be treated as household waste. Instead it shall be handed 
over  to  the  appicable  collection  point  for  the  recycling  of 
electrical and electronic equipment.

El  cableado  exterior  conectado  al  equipo  requiere  de  su 
instalación por una persona instruida o el uso de cables flexibles 
ya preparados.

The outer wiring connected to the device requires installation by 
an  instructed  person  or  the  use  of  a  flexible  cable  already 
prepared.

El equipo cuenta con dos conectores   de entrada en paralelo 
para facilitar la conexión de varias cajas en paralelo.

Note that the two Speakon input connectors are wired in parallel 
to provide easy parallel connection of several enclosures.

El colgado del equipo sólo debe realizarse utilizando los herrajes 
de  colgado  recomendados  y  por  personal  cualificado.  No 
cuelgue la caja de las asas.

The appliance should be flown only from the rigging points and 
by  qualified  personnel.  Do  not  suspend  the  box  from  the 
handles.

Para  las  cajas  con  vaso  para  trípode,  la  altura  máxima  de 
seguridad desde el suelo a la base de la caja montada sobre 
trípode modelo 

TRD-2

, con pies a 55 cm del eje del trípode, es:

For enclosures with tripod socket, the maximum safety height 
from floor to bottom of enclosure when mounting on a 

TRD-2

 

tripod, with legs spread 55cm from the central pole, is:

55 cm

Manual del Usuario

 / action passive series / 

User’s Manual

Summary of Contents for Action 8

Page 1: ... utilizar el equipo lea la sección Precauciones de seguridad de este manual Conserveestemanualparafuturasconsultas Before operating the device please read the Safety precautions section of this manual Retainthismanualforfuturereference ...

Page 2: ...NGS SPECIFICATIONS 2x action 8 2x action 12 action 15 1x action 18 2x action 12 action 15 2x action 18 2x action 12 action 15 2x action 218 2x action 215 4x action M12 CONFIGURATIONS SAFETY PRECAUTIONS WARRANTY DECLARATION OF CONFORMITY Manual del Usuario action passive series User s Manual ...

Page 3: ...aduras ni coloque sobre él objetos que contengan líquidos tales como vasos y botellas Equipo IP 20 Do not expose this device to rain or moisture Do not place any objects containing liquids such as bottles or glasses on the top of the unit Do not splash liquids on the unit IP 20 equipment No emplace altavoces en proximidad a equipos sensibles a campos magnéticos tales como monitores de televisión o...

Page 4: ...ón en garantía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra All D A S products are warrantied against any manufacturing defect for a period of 2 years from date of purchase The warranty excludes damage from incorrect use of the product All warranty repairs must be exclusively undertaken by the factory or any of its authorised...

Page 5: ...95 CE l Directiva RAEE WEEE 2002 96 CE Y es conforme a las siguientes Normas Armonizadas Europeas In accordance with Harmonized European Norms l EN 60065 2002 Audio video and similar electronic apparatus Safety requirements l EN 55103 1 1996 Electromagnetic compatibility Product family standard for audio video audio visual and entertainment lighting control apparatus for professional use Part 1 Em...

Page 6: ...inish A rear located handle and a robust steel grille are provided A 35 mm tripod socket allows for stand mounting action M12 Dedicated stage monitor 12 bass loudspeaker Compression driver with titanium diaphragm Low profile enclosure design for minimum visual impact Black paint finish Stand mountable The action M12 is a dedicated stage monitor designed for use with external amplification The encl...

Page 7: ...ated pole mount socket permits mounting full range systems above the action 18 and two bar handles makes moving easy action 218 High output bass reflex subwoofer system Twin 18 loudspeakers Durable black paint finish Side located bar handles This high power bass reflex subwoofer system uses dual 18 bass loudspeakers equipped with 4 voice coils The exceptional power handling capacity and efficiency...

Page 8: ... 8 W 60 Hz 20 kHz D A S Audio s a Valencia MADE IN SPAIN action8 TRD 2 action 8 PS 400 Output B Output A Mixer Input B L R Input A DSP 26 INPUTS A B STEREO 0 775V ON N1918 CH B INPUT CH A INPUT PARALLEL 1 0V SENSITIVITY BRIDGE 1 44V OFF CH A CH B BRIDGE GROUND GND GND COLD COLD HOT HOT 2 3 1 FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH THE SAME FUSE TYPE SPEAKER OUTPUT ...

Page 9: ...ION ATTENTION RISK OF ELECTRIC SHOCK DO NOT OPEN DANGER D ELECTROCUTION NE PAS OUVRIR GND COLD HOT GND COLD HOT 2 3 1 N1918 CH B CH A BRIDGE CH A CH B BRIDGE 1 2 1 1 2 2 SPEAKER OUTPUT WARNING TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE VER MANUAL DE INSTRUCCIONES PARA LA CONEXIÓN REFER TO INSTRUCTIONS MANUAL FOR CONNECTION ANSCHLUSSWEISE BITTE DER ANL...

Page 10: ...OR MOISTURE VER MANUAL DE INSTRUCCIONES PARA LA CONEXIÓN REFER TO INSTRUCTIONS MANUAL FOR CONNECTION ANSCHLUSSWEISE BITTE DER ANLEITUNG ENTNEHMEN VOIR MANUEL D INSTRUCTIONS POUR LA CONNEXION CH A INPUT CH B INPUT D A S AUDIO S A VALENCIA SPAIN MADE IN CHINA 1 0V STEREO SENSITIVITY MODE GROUND 0 775V BRIDGE OFF 1 44V PARALLEL ON S N F 10A L 250V FUSE MODEL PS 800 230V 10A 50Hz 60Hz OUTPUT PWR PER C...

Page 11: ... MODEL PS 800 230V 10A 50Hz 60Hz OUTPUT PWR PER CH 390W 4 FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH THE SAME TYPE CH B 1 1 CAUTION ATTENTION RISK OF ELECTRIC SHOCK DO NOT OPEN DANGER D ELECTROCUTION NE PAS OUVRIR GND COLD HOT GND COLD HOT 2 3 1 N1918 PS 800 Mixer Output B Output B Input B Input B Input A Input A Output A Output A DSP 26 INPUTS A B FOR CONTINUED PROTECTION AGA...

Page 12: ...INA 1 0V STEREO SENSITIVITY MODE GROUND 0 775V BRIDGE OFF 1 44V PARALLEL ON S N F 10A L 250V FUSE MODEL PS 800 230V 10A 50Hz 60Hz OUTPUT PWR PER CH 390W 4 FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH THE SAME TYPE CH B 1 1 CAUTION ATTENTION RISK OF ELECTRIC SHOCK DO NOT OPEN DANGER D ELECTROCUTION NE PAS OUVRIR GND COLD HOT GND COLD HOT 2 3 1 N1918 action 215 action 215 PS 1400 ...

Page 13: ...H B INPUT D A S AUDIO S A VALENCIA SPAIN MADE IN CHINA 1 0V STEREO SENSITIVITY MODE GROUND 0 775V BRIDGE OFF 1 44V PARALLEL ON S N F 10A L 250V FUSE MODEL PS 800 230V 10A 50Hz 60Hz OUTPUT PWR PER CH 390W 4 FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH THE SAME TYPE CH B 1 1 CAUTION ATTENTION RISK OF ELECTRIC SHOCK DO NOT OPEN DANGER D ELECTROCUTION NE PAS OUVRIR GND COLD HOT GND ...

Page 14: ...y factor and dynamically loaded with 142 kg 7 1 safety factor When flying a system the working load must be lower than the resistance of each individual flying point in the enclosure as well as each box Hanging hardware should be regularly inspected and suspect units replaced if in doubt This is important to avoid injury and absolutely no risks should be taken in this respect It is highly recommen...

Page 15: ... 330 kg 726 lb If using other hardware make sure it is rated to handle the required load When using eyebolts it is important to bear in mind that the rated working load is only true for a load applied in the plane of the eye and is significantly reduced for other angles The drawing illustrates the concept The table shows the variation of the working load as a function of the load angle In the case...

Page 16: ...ture Use only the screws and wall plugs supplied on surfaces that will provide sufficient support Do not use on surfaces such as plaster and gypsum It is highly recommended and in most parts of the world mandatory that a safety cable be used to secure the enclosure to the structure To ensure optimum safety the installation should be checked thoroughly at regular intervals replacing all deteriorate...

Page 17: ...on 218 action 12 Bottom View 324 Right View Front View 378 653 Rear View 624 Rear View 650 Top View Right View 540 Front View Rear View 1067 Right View 540 Front View Top View 670 Rear View 474 Bottom View 1154 Right View 447 Front View 436 Bottom View 774 Right View 446 Front View Rear View 645 420 316 Bottom View Right View Front View Rear View ...

Page 18: ...tors Dimensions H x W x D Weight Accessories action 8 action 15 600 W 1400 W 150 W 350 W 80º x 80º 80º x 50º 92 dB SPL 96 dB SPL 120 dB 131 dB 8 ohms 8 ohms LF 8B 8B LF 2 x 15Mi GM 15Mi HF M 26 GM M 26 HF M 34 GM M 34 Birch Plywood Birch Plywood Black Paint Black Paint 2 x NL4 Speakon 2 x NL4 Speakon AXW 1 TRD 2 TRD 6 ANL 2 TRD 2 TRD 6 47 5 x 27 9 x 25 5 cm 77 4 x 44 6 x 43 6 cm 18 7 x 11 x 10 in ...

Page 19: ...8DAS4USA Tel 1 305 436 0521 Fax 1 305 436 0528 D A S AUDIO ASIA PTE LTD 25 Kaki Bukit Crescent 01 00 02 00 Kaki Bukit Techpark 1 Singapore 416256 Tel 65 6742 0151 Fax 65 6742 0157 D A S AUDIO S A C Islas Baleares 24 46988 Fuente del Jarro Valencia SPAIN Tel 96 134 0525 Tel Intl 34 96 134 0860 Fax 96 134 0607 Fax Intl 34 96 134 0607 ...

Reviews: