12
PEDESTAL MOUNT : OUTWARD SWING
All OUTWARD swing installations require SHORT crank arms and LONG conrods.
When outward swing gates are setup the operators will protrude into the driveway by 155mm
on each side of the driveway. Any attempt to mount the operators in any other manner will
cause operational problems with the gates.
B
GATE IN OPEN POSITION
NOTE:
1.
Accurate positioning of the pedestal is criti-
cal.
2.
Gate can only open a maximum of 90°
3.
Order short Crank Arms when installing out-
ward swing operators.
4.
Recommended that measurement
A
should
not be less than 475mm.
5.
The Crank Arm and Conrod must be in a
straight line when in the open position.
6.
The gate must be set in the OPEN position.
ANGLE
A
B
C
D
90°
475
70
772
1000
90°
500
70
550
890
90°
800
70
500
1110
NB:
All measurements are given as
guidelines. Each installation will vary
marginally.
SETTING GATE OPENING ANGLE
A
Face of gate
D
C
B
CRANK ARM
This system uses
the short (205mm)
Crank Arm.
AERIAL VIEW
21
DIPSWITCH SETTINGS
Auto-close is an option that allows the gate to close automatically after a chosen time delay, this delay
can be from 10 to 70 seconds. Auto-close is selected by using the dipswitches on the main PC Board.
Dipswitch numbers 6,7 and 8 are the auto-close time select switches. The times are as follows.
6 off ; 7 off; 8 off = no auto-close
6 on; 7 off; 8 off = 10 seconds
6 off; 7 on; 8 off = 20 seconds
6 off; 7 off; 8 on = 40 seconds
6 on; 7 on; 8 on = 70 seconds
Any combination can be used to select the desired auto-close time.
It is strongly recommended that DuraOptics safety beams are used when Auto-Close
is selected as this reduces the chance of the gate closing on an object and causing
injury or damage.
No’s 6; 7 & 8:
SETTING AUTO-CLOSE
AUTO-CLOSE
To set multi-user mode, place number 5 dipswitch in the ON position.
NOTE !!! If Multi-user is selected, an auto-close time must also be selected. If an auto-close
time is not selected, the gate will immediately close after opening.
MULTI-USER MODE
BEAMS AUTO-CLOSE
B.A.C. is not active with swing operators.
Number 2 dipswitch is used to activate the safety beams. If no safety beams are used, number 2 dipswitch
must be in the
ON
position. If safety beams are connected, number 2 dipswitch must be set to the OFF
position. NOTE if number 2 dipswitch is OFF and there are no beams connected, the gate will not close.
INFRARED SAFETY BEAMS
No.2:
ON IF NO BEAMS
No.5:
ON FOR MULTI-USER
No. 4:
MUST REMAIN OFF FOR SWING OPERATORS