EN / CZone® Meter Interface (MI) User & Installation Manual

 

4

 

 

         

3  SAFETY AND INSTALLATION PRECAUTIONS 

 

WARNINGS AND SYMBOLS

 

Safety instructions and warnings are marked in this manual by the following pictograms:  

CAUTION  

Special data, restrictions and rules with regard to preventing damage.  
 

WARNING  

A WARNING refers to possible injury to the user or significant material damage to the Meter Interface 
if the user does not (carefully) follow the procedures. 

 

A procedure, circumstance, etc, which deserves extra attention. 

 

    USE FOR INTENDED PURPOSE  

1.  The Meter Interface is constructed as per the applicable safety-technical guidelines. 

 

2.  Use the Meter Interface only: 

 

  In technically correct conditions  

  In a closed space, protected against rain, moisture, dust and condensation  

  Observing the instructions in the installation manual 

WARNING 

Never use the Meter Interface in locations where there is danger of gas or dust explosion or 

potentially flammable products!  
 

3.  Use of the Meter Interface other than mentioned in point 2 is not considered to be consistent with the intended 

purpose. BEP Marine is not liable for any damage resulting from the above.  

  ORGANIZATIONAL MEASURES 

The user must always: 

 

  Have access to the user's manual and be familiar with the contents of this manual 

 

  MAINTENANCE AND REPAIR 

  Switch off supply to the system

 

  Be sure that third parties cannot reverse the measures taken

 

  If maintenance and repairs are required, only use original spare parts 

 

  GENERAL SAFETY AND INSTALLATION PRECAUTIONS  

  Connection and protection must be done in accordance with local standards 

  Do not work on the Meter Interface or system if it is still connected to a power source. Only allow changes 

in your electrical system to

be carried out by qualified electricians 

 

  Check the wiring at least once a year. Defects such as loose connections, burned cables, etc. must be 

corrected immediately 

 

Summary of Contents for 80-911-0005-00

Page 1: ...Meter Interface MI User Installation Manual V2 0...

Page 2: ...Measures 4 Maintenance And Repair 4 General Safety and Installation Precautions 4 4 OVERVIEW 5 Description 5 Features 5 Component Overview 5 5 INSTALLATION 6 Guidelines 6 DC Connections 6 AC Connectio...

Page 3: ...es and measures Please keep this manual in a secure place GUARANTEE SPECIFICATIONS BEP Marine guarantees that this unit has been built according to the legally applicable standards and specifications...

Page 4: ...Meter Interface in locations where there is danger of gas or dust explosion or potentially flammable products 3 Use of the Meter Interface other than mentioned in point 2 is not considered to be cons...

Page 5: ...ES AC 3 x AC voltage inputs multi voltage 2 x AC current inputs Calculates true RMS power DC 3 x DC voltage inputs multi voltage 2 x DC current inputs Calculates battery capacity as Ampere hours and p...

Page 6: ...each input is fused at supply with a 1A fuse Voltage Input 3 is a voltage meter only Connect the current input from each shunt Ensure care is taken when wiring shunt into heavy DC system to make sure...

Page 7: ...nput 1 from transformer AC Current input 1 from transformer Note these are paired inputs for correct metering these must be matched to the same supply source matched to the same supply source for corr...

Page 8: ...es are present and transmitting data 4 Check that the Power indicator LED is green 5 Check the circuit s status LEDs for each individual circuit Refer to LED codes to diagnose any faults which need to...

Page 9: ...h Channel Not Configured 2x Red Flash Configuration Conflict 3x Red Flash Dip Switch Conflict 4x Red Flash Memory Comms Failure 5x Red Flash No Modules Detected 8x Red Flash Invalid Input Signal 2 Net...

Page 10: ...hese labels are to be fitted to the cover and to the module this prevents covers being swapped To record the module type and dipswitch settings use a permanent marker and strike through the applicable...

Page 11: ...A 2000 NETWORK Transformer common AC Voltage input 3 from transformer AC Voltage input 2 from transformer AC Current input 2 from transformer AC Voltage input 1 from transformer AC Current input 1 fro...

Page 12: ...H SWITCH BATTERY 1AMP FUSE 1AMP FUSE 450A 50mV SHUNT PUMP BILGE HORN WIPER BUS BAR BUS BAR NEGATIVE TWISTED PAIR OUTPUT INTERFACE TWO BATTERY ENGINE ALT 1 ALT 2 8 Way DC DC Negative DC voltage positiv...

Page 13: ...13 EN CZone Meter Interface MI User Installation Manual 10 Dimensions Figure 9 Dimensions...

Page 14: ...11 0042 00 TERM BLOCK MI 8 WAY PLUG 5mm PITCH 80 911 0043 00 DC CURRENT SHUNT 450A LB 450 50 CURRENT TRANSFORMER AC DIGITAL METER CT 10 3 AC VOLT TRANSDUCER FOR DIG CZONE MC12 AC VSEN 4 12 EMC ratings...

Page 15: ...15 EN CZone Meter Interface MI User Installation Manual 13 Declaration Of Conformity...

Reviews: