Cytech KP03 Quick Start Manual Download Page 2

announcements. KP04 and KP05 have the same

functions and specifications, except that KP04 is

mounted vertically (see above figure) and KP05 is

horizontal 

Specifications

y

Dim: 89 x 160 x 31 mm. Carton 92 x 165 x 45 mm

y

Weight: 177 g

y

2 lines by 16 character LCD 

y

Power Supply: 12V DC from Comfort System

y

Current Consumption:  50 mA idle (No voice)

y

Comfort IR codes received: RC01 codes

y

Speaker for announcement, intercom , messages.

y

Microphone for recording and Intercom

System Requirements

y

Comfort II Controller

Contents

y

KP04 or KP05 keypad

y

2 wall plugs and screws for mounting.

y

3 x 2 way removable terminal blocks

Connections to Comfort

y

JP1 – 12V/COM  Connected to 12V/COM (Comfort)

y

JP2 – KA/KB. Connected to KA/KB (Comfort.)

y

JP3 – VOICE/MIC  Connected to KP VOICE/MIC

(Comfort)

Cables

Shielded twisted 4-pair cable advisedfor wiring between

Comfort and keypads to avoid interference from mains

wiring and electrical appliances to Microphone signals.

Jumper Settings

y

JP4 – 3 pin header for Backlight . “Normal”  

(default) for backlight on when key is pressed,

Entry Alert or Alarm. “On” position switches

Backlight permanently on. 

y

JP6 – Keypad Key Beep volume. Open for softer

beep volume. It is shunted by default (i.e. loud).

y

JP7 – Tamper Shunt. Shunted to disable tamper

switch (Default), open to enable Tamper switch.

Reviews: