Cypress SPX-1200 Manual Download Page 4

©2006 Cypress Computer Systems,Inc. • www.cypressworld.com  

Page 4

Dip switch #5 is ON

Door Strike relay does NOT follow LED

1 2 3 4 5 6 7 8

On

Off

1 2 3 4 5 6 7 8

NOT USED
ALL OFF

  Switch
  6 7 8 
0        
1     x
2   x      
3   x x      
4 x    
5 x   x    
6 x x     
7 x x x    

Wiegand

Wiegand / No Filter

Strobed Rising Edge (MR-5)

Strobed Rising Edge (Dorado 644)

Strobed Rising (Mag-Tek)

Strobed Falling Edge

Reserved

F2F

x = ON

DIP Switch Settings- 

Quick Reference

CYPRESS SUPREX SPX-1200

Dip switch #4 is ON
-Disable Pullup resistors

Dip switch #4 is OFF
-Enable Pullup resistors

1 2 3 4 5 6 7 8

NOT USED
ALL OFF

  Switch
  6 7 8 
0        
1     x
2   x      
3   x x      
4 x    
5 x   x    
6 x x     
7 x x x    

Wiegand

Wiegand / No Filter

Strobed Rising Edge (MR-5)

Strobed Rising Edge (Dorado 644)

Strobed Rising (Mag-Tek)

Strobed Falling Edge

Reserved

F2F

x = ON

Dip switch #3 is OFF
-Normal Operation

Dip switch #3 is ON
-Alternate Relay Setting

CENTRAL Dip Switch Settings

REMOTE Dip Switch Settings

Summary of Contents for SPX-1200

Page 1: ...2006 Cypress Computer Systems Inc www cypressworld com Page 1 SPX 1200 Supervised Reader Extender Wiring Diagram and Operators Manual MAN FA SPX 1200 V1 04...

Page 2: ...al connections Page 9 10 Power connection Page 11 12 13 Communication connections Page 14 Reader data connections Page 15 16 17 Door strike relay Page 18 Alternate I O Function Dip Switch 5 Page 19 20...

Page 3: ...Aux Output 3 Line Line RS 232RX RS 232 TX Gnd Aux Input 1 Suprex 1200 Central Unit 8 24VDC Gnd 5Vdc J1 J2 J3 Alarm Output Line Line Rly N C Rly Com Rly N O RS 232RX RS 232 TX Gnd LED IN Aux Output 2...

Page 4: ...alling Edge Reserved F2F x ON DIP Switch Settings Quick Reference CYPRESS SUPREX SPX 1200 Dip switch 4 is ON Disable Pullup resistors Dip switch 4 is OFF Enable Pullup resistors 1 2 3 4 5 6 7 8 NOT US...

Page 5: ...eader and door gate hardware The reader data and status signals are sent over a single pair of wires up to 10 000 feet An RS 232 connection can also be used The SPX 1200 series has the ability to be f...

Page 6: ...configuration can be verified and any potential problems can be solved much easier than if the units are separated by several thousand feet We recommend that the installation proceed in the following...

Page 7: ...ss Suprex supports multiple reader data formats Each data format can be set with the dipswitch The dip switch format will be read each time the unit powers up Mode 0 Wiegand mode Supports Wiegand data...

Page 8: ...O points and Power and Communications The Central and Remote are physically alike and will be identified by a sticker or permanent label with a large C or Central label and a large R or Remote label C...

Page 9: ...l Identification Central unit RS 232 RX Ground Data 0 Clock F2F Data 1 Data LED Panel Port Signals 8 24 VDC Ground 5 VDC Alarm Relay N O Alarm Relay Com Alarm Relay N C Aux Digital I O 1 Output Aux Di...

Page 10: ...Terminal Identification Remote unit RS 232 RX Ground Data 0 Clock F2F Data 1 Data LED Reader Signals 8 24 VDC Ground 5 VDC Alarm Relay N O Alarm Relay Com Alarm Relay N C Aux Digital I O 3 Output Aux...

Page 11: ...ntral and Remote units It requires 4 wires to connect the two units together A typical power supply would be a 12Vdc wall wart rated at 500 ma The power supply can be located at either the Central or...

Page 12: ...is method uses two power supplies One to power the Central and the other to power the Remote unit It requires 2 wires to connect the two units together The power supplies are located at both the Centr...

Page 13: ...ower both units The power supplies are located at both the Central and Remote unit The 5 volt power must be connected to the reader interface 5 Volt and Ground connections The other unit can be suppli...

Page 14: ...the units connected using A B or C power connections turn on the power supply Only power and communications connections should be made at this point Data and I O connections should be made after powe...

Page 15: ...ader Central Unit Remote Unit The SPX 1200 has eliminated the need for Pullup resistors in most installations Dipswitch 4 controls whether the internal pullup resistors are turned on or not Dipswitch...

Page 16: ...ss Computer Systems Inc www cypressworld com Page 16 Detailed Reader Port Connections Central unit Power supply connections are not shown for clarity Ground Data 0 Clock F2F Data 1 Data LED Panel Port...

Page 17: ...Detailed Reader Port Connections Remote unit Power supply connections not shown to clarify data connections Data 0 Clock F2F Data 1 Data LED Ground 5 VDC R Reader Interface 5 Vdc Reader Data 0 Clock F...

Page 18: ...nd 0 volt reference it will trigger the LED output and Strike relay on the Remote unit The dip switch on the Central unit can set a different mode for triggering the Door Strike 1 2 3 4 5 6 7 8 N C Co...

Page 19: ...the Door Strike Relay on the Remote unit will operate This is a dual purpose input and also serves as an additional I O channel See below There is an auxiliary digital output on the Remote unit This i...

Page 20: ...and Digital output 1 on the Central unit The Alarm signal will be output on Digital Output 1 and the Digital Output 1 signal will be output using the Relay on the Central unit Note Loss of communicati...

Page 21: ...atus of its associated input A signal change on Input 1 will be seen on Output 1 input 2 on output 2 input 3 on output 3 The Alarm Output is activated when there is a loss of communication between the...

Page 22: ...AC Suprex 1200 Remote Unit J1 J2 J3 Aux Output 3 Aux Input 1 Suprex 1200 Central Unit J1 J2 J3 Alarm Output Rly N C Rly Com Rly N O Aux Output 2 Aux Input 3 R C Rly N C Rly Com Rly N O Door Strike Aux...

Page 23: ...han 5 Volts can damage the board The digital inputs are pulled up to 5 Volts and operate as active low they will operate when connected to ground 0 Volts They can be driven by a digital output from a...

Page 24: ...ment utilizing 5 Volt logic level signals such as panels and gate controllers Check the manufacturers specifications for the equipment that you will interface to the Suprex to verify signal levels Oth...

Reviews: