![Cypress MB39C831-EVB-02 Operation Manual Download Page 15](http://html.mh-extra.com/html/cypress/mb39c831-evb-02/mb39c831-evb-02_operation-manual_2706014015.webp)
Setup and Verification
MB39C831-EVB-02 Thermal Energy Harvesting Evaluation Board Operation Guide, Doc. No. 002-08635 Rev. *A
15
Table 4-4. MPPT Settings of Charge Mode
S2
S1
S0
MPPT Values
SW1-3
JP8
SW1-2
JP7
SW1-1
JP6
Off
Short
Off
Short
Off
Short
50% (Initial Setting)
Off
Short
Off
Short
On
Open
55%
Off
Short
On
Open
Off
Short
60%
Off
Short
On
Open
On
Open
65%
On
Open
Off
Short
Off
Short
70%
On
Open
Off
Short
On
Open
75%
On
Open
On
Open
Off
Short
80%
On
Open
On
Open
On
Open
85%