COMMAND
Description and Parameters
SET AUTOMATION EVENT N1 UART A WAIT N2 SEC
Set the wait time (in seconds) before sending a command after RS-
232 automation event
N1
is triggered.
Available values for
N1
:
1
[Power on]
2
[Out A sync active]
3
[Out A sync lost]
4
[Out B sync active]
5
[Out B sync lost]
N2
= 0 ~ 240
[Wait time in seconds]
GET AUTOMATION EVENT N1 UART A WAIT
Show the currently set wait time (in seconds) observed before
sending a command after RS-232 automation event
N1
is triggered.
Available values for
N1
:
1
[Power on]
2
[Out A sync active]
3
[Out A sync lost]
4
[Out B sync active]
5
[Out B sync lost]
GET AUTOMATION EVENT CEC COMMAND LIST
List all available CEC commands for use with automation events.