CYP MOD-32 Operation Manual Download Page 1

MOD-32

32x32 Modular Matrix

OPERATION MANUAL

Summary of Contents for MOD-32

Page 1: ...MOD 32 32x32 Modular Matrix OPERATION MANUAL...

Page 2: ......

Page 3: ...ves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored in a retrie...

Page 4: ...through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not u...

Page 5: ...gnment 13 6 6 RS 232 Telnet Command 14 6 7 RS 232 IP to RS 232 RX Output Configuration 16 6 8 Telnet Control 17 6 9 Web GUI Control 19 7 Connection Diagram 21 7 1 Example installation 32x32 HDMI Matri...

Page 6: ...le internal PSU s which allow for easy inspection and maintenance with zero down time Also included is a DVI output for local monitoring of the output allowing installers to easily monitor test and co...

Page 7: ...ough of LPCM 7 1CH Dolby TrueHD Dolby Digital Plus and DTS HD Master Audio Supports a wide range of PC and HDTV resolutions from VGA to WUXGA and 480i to 1080p and 4Kx2K dependent on module configurat...

Page 8: ...LED is flashing it means the temperature inside is too high and air circulation may have been restricted 3 RETURN Press this button to return back or exit the current selection 4 PAGE Use these button...

Page 9: ...o be displayed on the required output The sequence should be OUT IN Select the Input OUT IN Select the output Enter 9 Plus Press this button when multiple outputs are required for a selected input Thi...

Page 10: ...t the remote being used is within the direct line of sight of the IR extender RS 232 Connect with a D Sub 9 pin cable to a PC Laptop device or RS 232 Control system for RS 232 control of the Matrix or...

Page 11: ...WER Supply The device will automatically turn ON when connected to an active power supply 5 Ventilation Fan This fan will automatically operate when the device is switched ON Do not block the exhaust...

Page 12: ...put selection 4 ENTER Press to confirm the present input output selection 5 INPUT Input port selection IR Control From the front panel 1 Select the output zone 1 32 2 Select the input source 1 32 3 Pr...

Page 13: ...13 6 5 IR Cable Pin Assignment 3 1 2 3 2 1 Power 5V IR Blaster Signal NC IR Signal Power 5V Ground IR Receiver IR Emitter...

Page 14: ...DCPOFF x Set input port x 01 32 HDCP to OFF HDCPONALL Set ALL input port s HDCP to ON HDCPOFFALL Set ALL Input port s HDCP to OFF HDCPSTATUS Show the HDCP status of all outputs 0 disabled 1 enable MUT...

Page 15: ...ssigned to Output x 01 32 EDIDSTATUS Report the status of the EDID Modes of all input ports UART x y str Write UART string to output port x in out y 01 32 str string UARTBAUD x y Set the UART Baud rat...

Page 16: ...a port the command is STATUSUART Default is 19200bps 2 To set the Baud rate the command is UARTBAUD x y x output port 01 32 y Baud rate e g to set the baud rate of Output 8 to 115200 bps you would se...

Page 17: ...art menu and type cmd in the Search field then press enter Under Windows XP go to the Start menu and click on Run type cmd with then press enter Under Mac OS X go to Go Applications Utilities Terminal...

Page 18: ...ll IP configurations To reset the IP type RSTIP and to use a static IP type SETIP For a full list of commands see Section 6 4 Note Commands will not be executed unless followed by a carriage return Co...

Page 19: ...active network as the Matrix open a web browser and type the device s IP address on the web address entry bar The browser will display the device s status control and User setting pages Click on the...

Page 20: ...ou to reset the IP configuration The system will ask for a reboot of the device each time any of the settings are changed The IP address needed to access the Web GUI control will also need to be chang...

Page 21: ...ne Tablet device for WebGui Control Local Monitor Wireless Router RS 232 Equipped PC or RS 232 Control System IR Extender For IR control of the matrix only Power Supply Backup Power Supply for uninter...

Page 22: ...IN IR OUT IN IR OUT IN IR OUT IN IR OUT IN IR OUT IN IR OUT IN AUDIO IN AUDIO AUDIO VGA IN VGA IN VGA IN IN IN AUDIO AUDIO VGA IN IN IN VGA IN AUDIO AUDIO VGA IN VGA IN VGA IN IN AUDIO IN IN 4K UHD IN...

Page 23: ...AT5e 6 7 dependent on module on module configuration Power Supply 2 AC 110 240V US EU standards CE FCC UL certified HMDICableI ODistance 15m 8 bits 10m 12 bits Dimensions 482 W 494 D 233 H Weight 15kg...

Page 24: ...VGA WUXGA 60RB HD 480i 1080p Audio transmission LPCM7 1CH Dolby TrueHD Dolby Digital Plus DTS HD Master Audio 32 192KHz Fs sample rate IN VGA8 8 Port VGA input module Input ports 8 VGA 8 2 5mm Audio...

Page 25: ...HD Dolby Digital Plus DTS HD Master Audio 32 192KHz Fs sample rate OUT HDMI 4K 8 8 Port 4Kx2K HDMI output module Video Bandwidth 25 340MHz Output ports 8 HDMI Video resolutions PC VGA WUXGA HD 480i 10...

Page 26: ...ital Plus DTS HD Master Audio 32 192KHz Fs samplerate OUT HDBT 4K 8 8 Port HDBaseT output module Video Bandwidth 300MHz 10 2Gbps Features Support HDBaseT PoC IR RS232 Ethernet Output ports 8 CAT5e 6 8...

Page 27: ...36 bits 3D data rates lower than 5 3 Gbps or below 225 MHz TMDS clock OUT HBT4P 8 OUT HBT5P 4K 8 CABLE DISTANCE Cable Type Range Pixelclock rate VideoData Rate SupportedVideo CAT5E 6 7 100 m 225 MHz...

Page 28: ...face EDID Extended Display Identi cation Data GUI Graphical User Interface HDCP High bandwidth Digital Content Protection HDMI High Definition Multimedia Interface HDTV High Definition Television LCM...

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...CYP UK Ltd Unit 7 Shepperton Business Park Govett Avenue Shepperton Middlesex TW17 8BA Tel 44 0 20 3137 9180 Fax 44 0 20 3137 6279 Email sales cypeurope com www cypeurope com v1 03...

Reviews: