![CYP CSR-8PSU-12V Operation Manual Download Page 16](http://html.mh-extra.com/html/cyp/csr-8psu-12v/csr-8psu-12v_operation-manual_2705379016.webp)
11
COMMAND
Description and Parameters
PWR N1 NAME N2
Rename power output
N1
.
N1
= 1 ~ 8
[Port number]
N2
= {Name String}
[16 characters max]
PWR_STATUS N1
Show the current power state (volts, watts, amps) of power
output
N1
.
N1
= 1 ~ 8
[Port number]
TEMPERATURE
Show details of the unit’s temperature and fan
control settings.
FAN_SET N1
Set non-“Auto Mode” fan speed or enable “Fan Auto Mode”.
Available values for
N1
:
0 ~ 100
[Disable Fan Auto Mode and set the
fan speed to the selected percentage]
AUTO
[Enable Fan Auto Mode]
FAN_SET N1 N2 N3
Set the fan speed and temperature threshold for the selected
automatic speed tier.
Available values for
N1
:
AUTO_LOW
[Auto fan setting to adjust]
AUTO_MID
AUTO_HIGH
N2
= 0 ~ 100
[Temperature threshold in °C]
N3
= 0 ~ 100
[Fan speed in percent]
Note: Commands will not be executed unless followed by a carriage
return. Commands are not case-sensitive.