8
6.4 EDID Management
Within the EDID Control section of the OSD menu are 2 menu items,
Mode & User, along with a details section displaying the content of
the currently selected EDID.
Mode: The current EDID may be changed by selecting and changing
the Mode option. There are 6 pre-defined “Internal” EDIDs, an
“External” EDID which passes the EDID from the connected display,
and a “User” EDID which is user-replaceable. To return the User EDID to
its original value, please perform a factory reset on the unit.
The 6 Internal EDIDs are:
1. FHD (1080p60Hz) with LPCM 2.0
2. FHD (1080p60Hz) with LPCM 7.1 & Bitstream
3. 4K UHD (4K@30Hz) with LPCM 2.0
4. 4K UHD (4K@30Hz) with LPCM 7.1 & Bitstream
5. 4K+ UHD (4K@60Hz, 4:4:4, 8-bit) with LPCM 2.0
6. 4K+ UHD (4K@60Hz, 4:4:4, 8-bit) with LPCM 7.1 & Bitstream
User:
The User EDID may be copied from a currently connected
display, or uploaded from a USB thumb drive plugged into the USB slot
on the unit.
• Any EDID from a connected HDMI display can be stored as a User
EDID by selecting “Copy External” from the User OSD menu and
pressing the ENTER button. If the EDID was copied successfully the
OSD will display a “Copy OK” message.
• Previously saved EDID files (USER_EDID_*.bin format) can be
uploaded into the unit by inserting a USB thumb drive containing the
new EDID file in the root directory, selecting “Copy from USB”
from the User OSD menu, and pressing the ENTER button. If the EDID
was copied successfully the OSD will display a “Copy OK” message.