background image

6

Note: Commands will not be executed unless followed by a carriage 

return. Commands are not case-sensitive.

6.4 EDID Commander

(1) This unit uses an EDID Management application which allows the 

user to copy the EDID from an attached display, edit an existing 

EDID file stored on the PC or create a basic EDID from scratch. The 

EDID can then be uploaded to the unit for use.

(2) Please obtain the EDID Management software from your 

authorized dealer and save it in a directory where you can easily 

find it.

(3) Before connecting the unit to your PC, please install the 

appropriate Virtual COM Port Driver depending on your Windows 

version. Next, install the EDID Management software.

(4) After the installation has successfully completed, an icon for it will 

appear on the windows desktop. Launch the software by double-

clicking on the icon and the EDID Management device detection 

window will open up on your screen.

(5) After launching the software, power the unit on and then connect 

it to the PC/laptop using a USB cable. Click on the “

 Search” 

button and any detected units will be displayed in the list. Clicking 

on a detected unit will open the EDID Commander window.

Summary of Contents for CPLUS-V11PI

Page 1: ...CPLUS V11PI 4K UHD HDMI Audio Inserter Operation Manual Operation Manual ...

Page 2: ......

Page 3: ...echnology reserves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored in a retrieval system or any of its part translated into any language or computer file in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without expre...

Page 4: ...r push an object of any kind into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To prote...

Page 5: ...s and Functions 3 6 1 Front Panel 3 6 2 Rear Panel 4 6 3 Virtual COM Port Control 4 6 4 EDID Commander 6 6 4 1 EDID Controller Tab 7 6 4 2 EDID Creator Tab 8 6 4 3 System Tab 9 7 Connection Diagram 10 8 Specifications 11 8 1 Technical Specifications 11 8 2 Video Specifications 12 8 3 Audio Specifications 13 9 Acronyms 14 ...

Page 6: ...PCM 7 1 with audio sampling rates up to 192kHz Built in EDID management support allows the user select from multiple EDIDs and with the use of optional PC software to upload download or edit EDID files 2 APPLICATIONS Combines external audio and DVI video via DVI to HDMI adaptor to be output as an HDMI signal Replaces audio in the original HDMI signal with an external audio source AV system integra...

Page 7: ...udio formats over HDMI Supports embedding external audio sources analog stereo or digital S PDIF into an existing HDMI source or adding audio to a DVI source output as HDMI Supports HDMI audio sampling rates up to 192kHz Supports the following S PDIF audio sampling rates 32kHz 44 1kHz 48kHz 88 2kHz 96kHz 192kHz Provides EDID management with EDID bypass and 2 user modifiable EDIDs PC based EDID man...

Page 8: ...e when a live non LPCM source typically Bitstream has been detected Note When this LED is lit please ensure that the connected HDMI display device supports the Bitstream audio format being inserted 5 BYPASS OPTICAL L R This switch selects the source of the audio to be embedded in the HDMI output BYPASS passes the audio directly from the HDMI input to the HDMI output without modification OPTICAL em...

Page 9: ...f a device such as an AV receiver CD player or DVD player L R IN Connect to the stereo analog output of a device such as a CD player PC or DVD player 4 DC 5V Plug the 5V DC power adapter into the unit and connect it to an AC wall outlet for power 6 3 Virtual COM Port Control COM PORT SETTINGS Baud rate 115200 Data bits 8 Parity None Stop bits 1 Flow control None COMMAND DESCRIPTION PARAMETERS Show...

Page 10: ... HDCP handling mode EDIDIN N1 Set the EDID to use with the HDMI input Available values for N1 1 FHD 2CH 2 FHD MCH 3 4K UHD 2CH 4 4K UHD MCH 5 4K UHD 2CH 6 4K UHD MCH 7 User EDID 8 Sink s EDID EDIDIN Show the current EDID selection ECHO N1 Set the console text echo mode behavior Available values for N1 0 Text echoing is off 1 Text echoing is on ECHO Show the current text echoing mode FADEFAULT Rese...

Page 11: ...e you can easily find it 3 Before connecting the unit to your PC please install the appropriate Virtual COM Port Driver depending on your Windows version Next install the EDID Management software 4 After the installation has successfully completed an icon for it will appear on the windows desktop Launch the software by double clicking on the icon and the EDID Management device detection window wil...

Page 12: ... 30Hz with LPCM 2 0 4K UHD MCH 4K 30Hz with LPCM 7 1 Bitstream 4K UHD 2CH 4K 60Hz 4 4 4 8 bit with LPCM 2 0 4K UHD MCH 4K 60Hz 4 4 4 8 bit with LPCM 7 1 Bitstream Save Upload Analysis EDIDs may be saved to a PC uploaded from a PC or analyzed Save Any EDID from the unit or the connected HDMI display can be saved to your PC as a bin file by selecting the EDID source from the drop down menu and then ...

Page 13: ... bin file has been selected and loaded the EDID fields will be populated with the information from that file The same will happen when the EDID is copied from the EDID Analyzer window Edit The following tabs provide access to a wide range of EDID information which can be edited Descriptor This tab allows for the editing of various description and information fields within the EDID file such as Man...

Page 14: ...n be saved to a bin file locally or uploaded directly to the unit using the Save and Upload icons respectively 6 4 3 System Tab Configuration Firmware Select the System tab to edit the unit s description select the Rename icon to reset the unit to factory defaults select the Reset icon and to view the unit s current hardware and firmware version information ...

Page 15: ...10 7 CONNECTION DIAGRAM HDMI IN HDMI OUT OPTICAL R L AUDIO IN DC 5V Game Console 4K Media Player UHDTV Power Supply Virtual COM Port Enabled PC HDMI Output USB HDMI Input Stereo Input Optical Input ...

Page 16: ...aud Rate Up to 115200bps Power Supply 5V 2 6A DC US EU standards CE FCC UL certified ESD Protection Human Body Model 8kV Air Discharge 4kV Contact Discharge Dimensions 128mm 25mm 108mm W H D Case Only 128mm 25mm 118mm W H D All Inclusive Weight 358g Chassis Material Metal Silkscreen Color Black Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 60 C 4 F 140 F Relative Humidity 20 9...

Page 17: ... 85 1024 768 60 70 75 85 1280 720 50 60 1280 768 60 75 85 1280 800 60 1280 1024 60 1360 768 60 1600 1200 60 1920 1200 60 RB 720 480p 60 720 576p 50 1280 720p 60 1920 1080i 50 60 1920 1080p 24 25 30 50 60 3840 2160p YUV 4 2 0 50 60 4096 2160p YUV 4 2 0 50 60 3840 2160p 24 25 30 50 60 4096 2160p 24 25 30 50 60 ...

Page 18: ...Optical Analog Level 0dBFs 0dBFs 2Vrms Frequency 1kHz 1kHz 1kHz Measurement Output Connector HDMI Output Level 0 1dB THD N 0 01 Frequency Response 1dBFS SNR 80dB Crosstalk 80dB Audio Sampling Rates HDMI 32 44 1 48 88 2 96 176 4 192kHz Passthrough S PDIF 32 44 1 48 88 2 96 192kHz Passthrough ...

Page 19: ...l Interface EDID Extended Display Identification Data HD High Definition HDCP High bandwidth Digital Content Protection HDMI High Definition Multimedia Interface HDR High Dynamic Range LED Light Emitting Diode LPCM Linear Pulse Code Modulation PC Personal Computer S PDIF Sony Philips Digital Interface Format SD Standard Definition UHD Ultra High Definition USB Universal Serial Bus ...

Page 20: ...CYPRESS TECHNOLOGY CO LTD www cypress com tw ...