19
COMMAND
DESCRIPTION
ZoneLineOut M Name={NameString}
Set the verbose name of a
zone line output. Maximum 32
characters.
M = A~H
Note: Can only rename one
port at a time. Multi-port is not
supported.
ExtLineOut M AudioSrc=XXX
Set the audio source for an
extended line output.
M = 1~4
Available XXX values:
HDMI_In n [n = 1~10]
OpticIn n [n = 1~2]
CoaxIn n [n = 1~2]
AnalogIn n [n = 1~4]
OAR_In n [n = A~H]
CAT_In n [n = 1~2]
MixerOut n [n = 1~3]
ExtLineOut M Treble=XXX
Set the treble value for an
extended line output.
M = 1~4
XXX = -12~+12 (units: dB)
ExtLineOut M Bass=XXX
Set the bass value for an
extended line output.
M = 1~4
XXX = -12~+12 (units: dB)
ExtLineOut M Volume=XXX
Set the volume for an
extended line output.
M = 1~4
XXX = 0 ~ -100 (units: dB)