CYP CMSI-8H8CVL Operation Manual Download Page 1

CMSI-8H8CVL

HDBaseT™ Lite 8×8 HDMI Matrix over CAT5e/6/7

Operation Manual

Operation Manual

Summary of Contents for CMSI-8H8CVL

Page 1: ...CMSI 8H8CVL HDBaseT Lite 8 8 HDMI Matrix over CAT5e 6 7 Operation Manual Operation Manual ...

Page 2: ......

Page 3: ...erves the right to make improvements to this document and or product at any time and without notice COPYRIGHT NOTICE No part of this document may be reproduced transmitted transcribed stored in a retrieval system or any of its part translated into any language or computer file in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without express written pe...

Page 4: ...h an object of any kind into this product through any openings or empty slots in the unit as you may damage parts inside the unit Do not attach the power supply cabling to building surfaces Use only the supplied power supply unit PSU Do not use the PSU if it is damaged Do not allow anything to rest on the power cabling or allow any weight to be placed upon it or any person walk on it To protect th...

Page 5: ...ns 3 6 1 Front Panel 3 6 2 Rear Panel 4 6 3 Side Panel 5 6 4 Remote Control 5 6 5 IR Cable Pin Assignment 6 6 6 RS 232 Protocols 7 6 7 RS 232 and Telnet Commands 8 6 8 Telnet Control 9 6 9 Web GUI Control 11 7 Connection Diagram 13 8 Specifications 15 8 1 Technical Specifications 15 8 2 CAT5e 6 7 Cable Specification 16 9 Acronyms 16 ...

Page 6: ...igital audio formats such as LPCM 7 1CH Dolby TrueHD Dolby Digital Plus and DTS HD Master Audio as well as 3D content that can be displayed when connecting a 3D TV and 3D source 2 APPLICATIONS HDMI Matrix System Video TV wall display and control Security surveillance and control Commercial advertising display and control University lecture hall display and control Retail sales and demonstration 3 ...

Page 7: ... EDID settings Supports distances up to 60 meters through CAT5e 6 7 cables Supports 3D signal display dependent upon the output display EDID settings Supports HDMI input up to 15 meters at 8 bit resolution or 10 meters at 12 bit resolution Supports bi directional IR from input and output locations Supports RS 232 remote control on panel control and IP Control Telnet Web GUI 2U size design Supports...

Page 8: ...emote control signal of this device only 5 MENU Press this button to access the LCM menu system from here EDID settings can be managed and IP system settings can be displayed 6 IN OUT and 1 8 A H Press the OUT button and then the number buttons to select the required output ports and press IN button and then a single number button to select the required input source finally press the MENU button t...

Page 9: ...m the IR IN 4 ALL IR IN Connect to the IR extender for IR signal reception Ensure that the remote being used is within the direct line of sight of the IR extender It will send the signal to the receiver s IR OUT 5 SERVICE Manufacturer use only 6 IR OUT A H Connect to the IR blasters for IR signal transmission Place the IR blaster in direct line of sight of the equipment to be controlled It will tr...

Page 10: ...ck these areas or cover it with any object Please allow adequate space around the unit for air circulation 6 4 Remote Control 1 POWER Press this button to switch on the device or set it to standby mode 2 1 8 IN Input ports selection 1 8 3 A H OUT Output ports selection A H 1 2 3 ...

Page 11: ...6 6 5 IR Cable Pin Assignment 3 1 3 1 2 2 Power 5V IR Blaster Signal NC IR Signal Power 5V Grounding IR Extender IR Blaster ...

Page 12: ...ATRIX REMOTE CONTROL CONSOLE PIN Assignment PIN Assignment 1 NC 1 NC 2 Tx 2 Rx 3 Rx 3 Tx 4 NC 4 NC 5 GND 5 GND 6 NC 6 NC 7 NC 7 NC 8 NC 8 NC 9 NC 9 NC Baud Rate 19200 bps Data Bit 8 bit Parity None Stop Bit 1 bit Flow Control None ...

Page 13: ...CD to 1 8 at the same time SETIP IP SubNet GW Setting IP SubNet GateWay Static IP RSTIP IP configuration was reset to factory defaults DHCP IPCONFIG Display the current IP config P0 Power Off P1 Power On I1 I8 Switch all the output to 1 8 ST Display the current matrix state and firmware version RS System Reset to A1 B2 C3 etc EM Setting EDID MODE 1 STD 2 TV Display all available commands QUIT Exit...

Page 14: ... connected to the same active network To access the Telnet control in Windows 7 click on the Start menu and type cmd in the Search Field then press Enter see below for reference Under Windows XP go to the Start menu and click on Run type cmd then press Enter Under Mac OS X go to the file menu then navigate to Go Applications Utilities Terminal see below for reference ...

Page 15: ...yed on the device s LCM monitor by pressing the Menu button twice Type HELP to list the available commands see below for reference Type IPCONFIG To show all IP configurations To reset the IP type RSTIP and to use a set static IP type SETIP Note 1 All commands will not be executed unless followed by a carriage return Commands are case insensitive 2 If the IP is changed then the IP Address required ...

Page 16: ...he same active network as the Matrix open a web browser and type device s IP address on the web address entry bar The browser will display the device s status and the control and user settings pages Click on the Control tab to control power input output ports EDID and reset mode ...

Page 17: ...u to reset the IP configuration The system will ask for a reboot of the device every time any of the settings are changed The IP address needed to access the Web GUI control will also need to be changed accordingly on the web address entry bar ...

Page 18: ...MI IN H ZONE A 1 2 3 4 5 6 7 RX ZONE B Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link RX Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link ZONE C RX Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link ZONE D RX Power Extender Blaster IR 2 IR 1 RS232 Out Link ZONE E RX Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link IR BLASTER 1 5m 60 IR EXTENDER 7m 3m 3m 60 m...

Page 19: ...ter IR 2 IR 1 RS232 Out CAT5e 6 In Link RX Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link RX Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link RX Power Extender Blaster IR 2 IR 1 RS232 Out CAT5e 6 In Link ZONE E ZONE F ZONE G ZONE H Main Power Supply Receiver Units CAT5e 6 7 Cable 60m HDMI Inputs IR In Out HDMI Outputs IR In Out Source Equipment Displays ...

Page 20: ...e 6 7 9 IR Blaster ESD Protection Human body Model 8kV Air gap discharge 4kV Contact discharge Power Supply 24V 6 25A DC US EU standards CE FCC UL certified Dimensions 438mm W 255mm D 93mm H Weight 4458 g Chassis Material Metal Silkscreen Color Black Operating Temperature 0 ºC 40 ºC 32 ºF 104 ºF Storage Temperature 20 ºC 60 ºC 4 ºF 140 ºF Relative Humidity 20 90 RH non condensing Power Consumption...

Page 21: ...Ultra HD Video Up to 4K 2K 30Hz 9 ACRONYMS ACRONYM COMPLETE TERM CLI Command Line Interface DTS Digital Theater System DVI Digital Visual Interface EDID Extended Display Identification Data GUI Graphical User Interface HDCP High bandwidth Digital Content Protection HDMI High Definition Multimedia Interface HDTV High Definition Television LCM Liquid Crystal Module USB Universal Serial Bus VGA Video ...

Page 22: ......

Page 23: ......

Page 24: ...Home page http www cypress com tw CYPRESS TECHNOLOGY CO LTD 20130123 MPM CMSI8H8CVL ...

Reviews: